6.
Med Tekh ; (6): 39-45, 2010.
Article in Russian | MEDLINE | ID: mdl-21313746
10.
Med Tekh ; (4): 39-43, 2001.
Article in Russian | MEDLINE | ID: mdl-11534293

ABSTRACT

The paper deals with experimental studies into the level of hemolysis that accompanies the performance of artificial cardiac valves (ACV). The studies were conducted by two ways. The first study determined the level of hemolysis when artificial cardiac valves worked and donor blood performed. The second one was that a polymer was added to the model physiological fluid, the degree of hemolysis was determined by the changes occurring in the time of relaxation of elastic stress in the model fluid samples taken during tests. The experiments showed polyethylene oxide break-down to be the most accurately modelling process of hemolysis.


Subject(s)
Heart Valve Prosthesis , Hemolysis , Blood Donors , Humans , Polyethylene Glycols , Polymers , Prosthesis Design , Time Factors
11.
Artif Organs ; 19(7): 616-9, 1995 Jul.
Article in English | MEDLINE | ID: mdl-8572961

ABSTRACT

At present, hemolysis is one of the most important characteristics used to evaluate rotary blood pumps. However, the conditions of testing procedures in various research centers differ considerably. We proposed to conduct the experiments under conditions similar to those from clinical applications of arterial pumps in extracorporeal perfusion. Proceeding from these considerations, the following parameters of Hemolysis (H) testing were adopted: output, 6 L/min; difference of pressure, 300 mm Hg; initial hematocrit, 30 mg%; and initial hemolysis (PHbo) < 5 mg%. The channel pump IBP80 designed on the basis of the BP80 was tested using fresh human blood. The experimental results indicate that the H level due to the use of the IBP80 is 2-3 times less than H for the BP80. H dependence on the difference of pressure in the range between 200 and 300 mm Hg was noted for the BP80, which can be accounted for by the transition of the laminar conditions of flow to turbulence. According to the results of the hydrodynamic efficiency evaluation, the IBP80 is twice as efficient as the BP80.


Subject(s)
Heart-Assist Devices/standards , Hemolysis/physiology , Blood Flow Velocity/physiology , Blood Viscosity , Hematocrit , Models, Biological , Pressure
12.
Phys Rev B Condens Matter ; 51(5): 3195-3197, 1995 Feb 01.
Article in English | MEDLINE | ID: mdl-9979106
13.
Med Tekh ; (2): 18-21, 1992.
Article in Russian | MEDLINE | ID: mdl-1513234

ABSTRACT

Based on an analysis of 300 world information sources, 19 types of centrifugal blood pumps were ascertained. Five new designs suggested have an idea in common: combination of the inlet of the disk pump and of the outlet of the impeller pump. This allows uniting the merits of the above pumps and excluding their shortcomings. The designs suggested make it possible to solve the two basic problems: hemolysis and thrombogenesis inside the pumps. The use of the pumps designed on such a basis will afford a simple and reliable approach to heart function replacement.


Subject(s)
Blood , Centrifugation/instrumentation , Heart, Artificial , Animals , Equipment Design , Humans
14.
Artif Organs ; 15(5): 376-80, 1991 Oct.
Article in English | MEDLINE | ID: mdl-1741681

ABSTRACT

The totally artificial heart (TAH) is now in development in two trends. First, there is the development of a bridge system for temporary support of cardiac function. The TAH with the extracorporeal pneumatic driving system Sinus-IS is more efficient and safer. Parallel with this, a portable pneumatic driving system has been developed. That can be considered a stage in the development of the second trend: a totally implantable TAH. This article reviews problems of building of the Micron energy system to be used in implantable TAH designs.


Subject(s)
Electric Power Supplies , Heart, Artificial , Animals , Equipment Design , Humans , Prosthesis Design
15.
Anesteziol Reanimatol ; (4): 3-11, 1991.
Article in Russian | MEDLINE | ID: mdl-1952234

ABSTRACT

The first clinical experience of anesthesiological management during 6 orthotopic liver transplantations (5 primary operations and 1 retransplantation) in 2 males and 3 females, aged 20 to 52 years, is presented. The method of general anesthesia is described--the use of veno-venous bypass without systemic heparinization and rapid infusion system. Hemodynamic, temperature, metabolic and coagulologic homeostasis disturbances are analysed at different stages of orthotopic liver transplantation, especially upon reperfusion of the donor organ. The tactics of infusion-transfusion therapy, as well as correction of electrolyte disturbances and blood coagulation disorders are being discussed. Different intraoperative complications are characterized. It is concluded that anesthesiological management of liver transplantations is one of the most complex problems of modern anesthesiology which takes joint effort of a large team of specialists: surgeons, anesthesiologists, perfusiologists, transfusiologists, and laboratory assistants specializing in different areas.


Subject(s)
Anesthesia, General/methods , Liver Transplantation/methods , Adult , Female , Humans , Male , Middle Aged , Reoperation
16.
Perfusion ; 6(2): 115-21, 1991.
Article in English | MEDLINE | ID: mdl-10171158

ABSTRACT

Analysis of 350 different sources of information from leading countries of the world enabled us to determine the availability of 20 different designs of centrifugal and rotary blood pumps. Most of them are for extracorporeal applications with radial pumping wheels of disc or vane type. The prospect of improving these designs was suggested by a combination of these two types. Five new designs based on the Biomedicus have been produced. Basic calculations are given for one of these with respect to limitations for shear stresses. It is proposed that the suggested designs will allow reductions in thrombosis and haemolysis which are the main problems for these pump designs.


Subject(s)
Extracorporeal Circulation/instrumentation , Heart-Lung Machine/supply & distribution , Animals , Centrifugation , Equipment Design
17.
Khirurgiia (Mosk) ; (1): 98-106, 1991 Jan.
Article in Russian | MEDLINE | ID: mdl-2041326

ABSTRACT

The article deals with material concerning the performance of 4 operations for orthotopic liver transplantation (OLT). The operations were carried out on 2 males and 2 females whose ages ranged from 20 to 52 years. The indications for OLT were as follows: ++hemangioendothelioma of the liver, hepatocellular carcinoma, cirrhosis-carcinoma of the liver, and metastatic affection of the liver. One male patient died immediately after the end of the operation, another patient died 3 days after the operation due to nonfunctioning of the transplant. In 2 female patients the operations were carried out successfully. One of them was discharged from the clinic in 62 days in a satisfactory conditions and a well functioning transplant. The other patient died from a complication which was not connected with the operation--perforation of the small intestine 69 days after OLT. The technical aspects of and the provision for the operation and the postoperative management of patients are discussed. The encountered complications are analysed.


Subject(s)
Liver Cirrhosis/surgery , Liver Neoplasms/surgery , Liver Transplantation/methods , Tissue and Organ Procurement/methods , Adult , Female , Humans , Male , Middle Aged , Moscow , Tissue Donors , Transplantation, Homologous
18.
Vestn Otorinolaringol ; (6): 62-5, 1990.
Article in Russian | MEDLINE | ID: mdl-2075682

ABSTRACT

The present authors maintain that the surgical approach to the antrum via the mastoid bone as a method of treating chronic purulent otitis media is very promising because it saves bone conduction structures of the middle ear. In order to provide accurate and safe dissection of the antrum, the authors measured the angle between the external auditory meatus and the horizontal skull plane. As they have previously demonstrated, this angle is correlated with the antrum displacement upwards or downwards. On the basis of over 500 observations, the authors have concluded that the angle increases on the average from 13 degrees to 25 degrees at the age of 5 to 40 years and then decreases, reaching 18 degrees by the age of 70 years. The authors recommend to measure the surgical angle for all types of antrotomic intervention, using contrast X-ray ++ of the auditory meatus in the normal anterior projection of the skull.


Subject(s)
Mastoid/surgery , Otitis Media, Suppurative/surgery , Adolescent , Adult , Age Factors , Aged , Cephalometry , Child , Child, Preschool , Chronic Disease , Humans , Middle Aged , Otitis Media, Suppurative/diagnostic imaging , Otitis Media, Suppurative/pathology , Radiography
19.
Med Tekh ; (4): 37-40, 1990.
Article in Russian | MEDLINE | ID: mdl-2215174

ABSTRACT

The authors have designed a pneumatic drive, which differs from the known ones in that it contains two electromagnetic two-linear and two-positioned air distributors while the motor operates in the mode excluding the change of its axis direction. This affords using a standard crank mechanism as a transformer of rotary motion to translational motion and reducing several times the power consumed. Besides, the two-linear and two-positioned air distributors allow a possibility of exercising a separate control over the time of the systole-diastole phases of the left and right ventricles. In this case both ventricles can work at 100% filling whereby maintaining the capacity of the artificial heart without additional energy consumption.


Subject(s)
Heart, Artificial , Electric Power Supplies , Equipment Design , Humans
20.
Med Tekh ; (1): 28-31, 1990.
Article in Russian | MEDLINE | ID: mdl-2187137

ABSTRACT

The paper is concerned with one of the trends in the design of outfits for blood forcing, namely with centrifugal pumps. Advantages and shortcomings of such pumps are assessed as compared to roller and other type pumps for blood. Unsolved problems are outlined. Based on a comparative analysis, six main designs are distinguished, the principles of the action, the scope of uses and characteristics are depicted. The conclusion is made that this type of pumps holds promise for the use in cardiosurgical clinics of the USSR.


Subject(s)
Heart-Assist Devices , Equipment Design , Humans