Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Publication year range
1.
No Shinkei Geka ; 48(3): 231-236, 2020 Mar.
Article in Japanese | MEDLINE | ID: mdl-32201392

ABSTRACT

Erdheim-Chester disease(E-CD)is a rare pathology characterized by systematic granulomatosis that occasionally involves the central nervous system. We report about a 68-year-old woman with E-CD who presented with right-side visual disturbance. Magnetic resonance imaging showed a suprasellar tumor that elevated the right optic nerve and involved the right internal carotid and right anterior choroidal arteries. The tumor was partially resected via a trans-Sylvian approach and was histologically diagnosed as a granuloma. Considering the abnormal findings of postoperative X-ray and 99 mTc bone scintigraphy of the long bones, the pathology was diagnosed as E-CD. After surgery, her right-side visual disturbances disappeared. However, 1 year later, she died of systemic infection and heart failure. Histological autopsy findings indicated numerous yellowish nodules in the heart, lung, and kidney with pericardial and pleural effusions and whole-body granulomatosis, including the brain. E-CD is a rare but critical disease. This pathological entity should be considered when encountering cases of intracranial granuloma to ensure its early diagnosis and appropriate treatment. Surgical resection of intracranial granulomas in patients with E-CD may promptly improve neurological dysfunction.


Subject(s)
Erdheim-Chester Disease/diagnostic imaging , Aged , Brain , Female , Granuloma , Humans , Magnetic Resonance Imaging , Radiography
2.
J Magn Reson Imaging ; 43(2): 384-90, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26149267

ABSTRACT

PURPOSE: 1) To assess the usefulness of an elastic belt bracing the upper abdomen for reducing the miscalculated areas of the pancreas on 3.0T magnetic resonance elastography (MRE); 2) to test whether MRE can detect difference of stiffness between normal pancreas and the focal pancreatic diseases. MATERIALS AND METHODS: Using an initial eight normal volunteers, miscalculated areas were compared between MRE with the elastic belt and without the belt on 3.0T MRI. Then, using the belt, MRE of the normal pancreas was measured using 14 volunteers and 11 patients with focal pancreatic lesions. RESULTS: The median (95% confidence interval [CI]) percentages of correctly calculated areas were 57.4% (32.9-63.0) with the elastic belt and 35.3% (11.4-60.4) without the belt (P = 0.0078). The stiffness of each pancreatic segment of the normal volunteers (mean ± SE) was 2.37 ± 0.16 kPa for the head, 2.46 ± 0.17 kPa for the body, and 2.58 ± 0.26 kPa for the tail. The stiffness of seven pancreatic cancers was 6.06 ± 0.49 kPa, which was higher than the overall pancreatic stiffness of the normal volunteers (2.47 ± 0.11 kPa, P < 0.0001). Stiffness of the pancreatic lesions in the head of 6.03 ± 0.42 kPa, body of 5.57 ± 0.82 kPa, and tail of 5.9 ± 1.9 kPa were also higher than those of corresponding segments of the normal volunteers (P = 0.0011, 0.0029, and 0.029, respectively). CONCLUSION: With the elastic belt, miscalculation of the pancreatic stiffness was reduced. MRE showed differences of stiffness between normal pancreas and pancreatic lesions.


Subject(s)
Elasticity Imaging Techniques/instrumentation , Elasticity Imaging Techniques/methods , Magnetic Resonance Imaging/instrumentation , Magnetic Resonance Imaging/methods , Pancreas/pathology , Pancreatic Neoplasms/pathology , Adult , Aged , Aged, 80 and over , Feasibility Studies , Female , Humans , Image Interpretation, Computer-Assisted , Male , Middle Aged , Pilot Projects , Reference Values , Reproducibility of Results
3.
Skeletal Radiol ; 39(3): 267-72, 2010 Mar.
Article in English | MEDLINE | ID: mdl-19434409

ABSTRACT

OBJECTIVE: To investigate the efficacy of '20 degrees -tilt anteroposterior (A-P) radiography' in the assessment of lateral condylar fractures of the distal humerus. MATERIALS AND METHODS: Eighteen children with lateral humeral condylar fractures were studied. Every child underwent conventional A-P and lateral radiography, and six children underwent multi-detector computed tomography (MDCT). For the investigation of 20 degrees -tilt radiography, ten children with lateral humeral condylar fractures had conventional and 20 degrees -tilt A-P and lateral radiography both preoperatively and postoperatively. Fragment dislocation was measured at the lateral and medial margins of the fracture on both the conventional A-P and 20 degrees -tilt A-P radiographs. RESULTS: The lateral condylar fragment was triangular and was most prominent posteriorly. The fracture line was typically tilted approximately 20 degrees to a reference line perpendicular to the long axis of the humerus in the lateral view. The extent of dislocation at the lateral and medial margins of the fracture site by 20 degrees -tilt A-P radiography (9.3 +/- 3.6 mm and 5.6 +/- 2.5 mm) was significantly wider than that measured by the conventional method (6.8 +/- 4.1 mm and 2.0 +/- 1.5 mm ), which may influence treatment. CONCLUSION: Twenty-degree-tilt A-P radiography may more precisely demonstrate fragment dislocation than standard radiographs and may influence patient treatment.


Subject(s)
Humeral Fractures/diagnostic imaging , Humerus/diagnostic imaging , Radiographic Image Enhancement/methods , Child , Child, Preschool , Female , Humans , Male , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...