Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-38842961

ABSTRACT

BACKGROUND: Tricuspid valve transcatheter edge-to-edge repair (T-TEER) is the most widely used transcatheter therapy to treat patients with tricuspid regurgitation (TR). OBJECTIVES: The aim of this study was to develop a simple anatomical score to predict procedural outcomes of T-TEER. METHODS: All patients (n = 168) who underwent T-TEER between January 2017 and November 2022 at 2 centers were included in the derivation cohort. Additionally, 126 patients from 2 separate institutions served as a validation cohort. T-TEER was performed using 2 commercially available technologies. Core laboratory assessment of procedural transesophageal echocardiograms was used to determine septolateral and anteroposterior coaptation gap, leaflet morphology, septal leaflet length and retraction, chordal structure density, tethering height, en face TR jet morphology and TR jet location, image quality, and the presence of intracardiac leads. A scoring system was derived using univariable and multivariable logistic regression. Endpoints assessed were immediate postprocedural TR reduction ≥2 grades and TR grade moderate or less. RESULTS: The median age was 82 years (Q1-Q3: 78-84 years); 48% of patients were women; and patients presented with severe (55%), massive (36%), and torrential (8%) TR. Five variables (septolateral coaptation gap, chordal structure density, en face TR jet morphology, TR jet location, and image quality) were identified as best predicting procedural outcome and were incorporated in the GLIDE (Gap, Location, Image quality, density, en-face TR morphology) score (range 0-5). TR reduction ≥2 grades and TR grade moderate or less were observed in >90% of patients with GLIDE scores of 0 and 1 and in only 5.6% and 16.7% of those with GLIDE scores ≥4. The GLIDE score was then externally validated in a separate cohort (area under the curve: 0.77; 95% CI: 0.69-0.86). TR reduction significantly correlated with functional improvement assessed by NYHA functional class and 6-minute walk distance at 3 months. CONCLUSIONS: The GLIDE score is a simple, 5-component score that is readily obtained during patient imaging and can predict successful T-TEER.

2.
J Clin Med ; 13(2)2024 Jan 16.
Article in English | MEDLINE | ID: mdl-38256618

ABSTRACT

Both the MitraClip and PASCAL systems offer transcatheter edge-to-edge repair (TEER) solutions for mitral regurgitation. Evidence indicates a lower technical success rate for TEER in complex degenerative mitral regurgitation (DMR) cases. We conducted a retrospective analysis of patients who underwent transcatheter edge-to-edge therapy for primary mitral regurgitation with advanced anatomy, defined as mitral regurgitation effective regurgitant orifice area (MR-EROA) ≥0.40 cm2 or large flail gap (≥5 mm) or width (≥7 mm) or Barlow's disease, that completed follow-up after 1 year. Our criteria were met by 27 patients treated with PASCAL and 18 with MitraClip. All patients exhibited a significant, equivalent short-term reduction in MR-EROA, mitral regurgitation vena contracta diameter (MR-VCD), regurgitant volume, and clinical status. At 1 year follow-up, reductions in MR-VCD, regurgitant volume, and MR-EROA remained significant for both groups without significant differences between groups. MR-Grade ≤ 1+ was achieved in 18 (66.7%) and 10 (55.6%) patients, respectively. At follow-up, no difference in hospitalization for cardiac decompensation was observed. Overall death was similar in both groups. Our study suggests that both the PASCAL and MitraClip systems significantly reduce mitral regurgitation even in advanced degenerative diseases. Within our limited data, we found no evidence of inferior performance of the PASCAL system.

4.
Eur Heart J Cardiovasc Imaging ; 25(3): 365-372, 2024 Feb 22.
Article in English | MEDLINE | ID: mdl-37861385

ABSTRACT

AIMS: Transcatheter tricuspid edge-to-edge repair (T-TEER) has gained widespread use for the treatment of tricuspid regurgitation (TR) in symptomatic patients with high operative risk. Although secondary TR is the most common pathology, some patients exhibit primary or predominantly primary TR. Characterization of patients with these pathologies in the T-TEER context has not been systematically performed. METHODS AND RESULTS: Patients assigned to T-TEER by the interdisciplinary heart team were consecutively recruited in two European centres over 4 years. Echocardiographic images were evaluated to distinguish between primary and secondary causes of TR. Both groups were compared concerning procedural results. A total of 339 patients were recruited, 13% with primary TR and 87% with secondary TR. Patients with primary TR had a smaller right ventricle (basal diameter 45 vs. 49 mm, P = 0.004), a better right ventricular function (fractional area change 45 vs. 41%, P = 0.001), a smaller right (28 vs. 34 cm2, P = 0.021) and left (52 vs. 67 mL/m2, P = 0.038) atrium, and a better left ventricular ejection fraction (60 vs. 52%, P = 0.005). The severity of TR was similar in primary and secondary TR at baseline (TR vena contracta width pre-interventional 13 ± 4 vs. 14 ± 5 mm, P = 0.19), and T-TEER significantly reduced TR in both groups (TR vena contracta width post-interventional 4 ± 3 vs. 5 ± 5 mm, P = 0.10). These findings remained stable after propensity score matching. Complications were similar between both groups. CONCLUSION: T-TEER confers equally safe and effective reduction of TR in patients with primary and secondary TR.


Subject(s)
Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Tricuspid Valve Prolapse , Humans , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve Insufficiency/etiology , Tricuspid Valve/surgery , Tricuspid Valve Prolapse/etiology , Tricuspid Valve Prolapse/surgery , Stroke Volume , Feasibility Studies , Treatment Outcome , Ventricular Function, Left , Heart Valve Prosthesis Implantation/methods , Cardiac Catheterization/methods
5.
JACC Cardiovasc Imaging ; 17(5): 471-485, 2024 May.
Article in English | MEDLINE | ID: mdl-38099912

ABSTRACT

BACKGROUND: The CLASP IID randomized trial (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial) demonstrated the safety and effectiveness of the PASCAL system for mitral transcatheter edge-to-edge repair (M-TEER) in patients at prohibitive surgical risk with significant symptomatic degenerative mitral regurgitation (DMR). OBJECTIVES: This study describes the echocardiographic methods and outcomes from the CLASP IID trial and analyzes baseline variables associated with residual mitral regurgitation (MR) ≤1+. METHODS: An independent echocardiographic core laboratory assessed echocardiographic parameters based on American Society of Echocardiography guidelines focusing on MR mechanism, severity, and feasibility of M-TEER. Factors associated with residual MR ≤1+ were identified using logistic regression. RESULTS: In 180 randomized patients, baseline echocardiographic parameters were well matched between the PASCAL (n = 117) and MitraClip (n = 63) groups, with flail leaflets present in 79.2% of patients. Baseline MR was 4+ in 76.4% and 3+ in 23.6% of patients. All patients achieved MR ≤2+ at discharge. The proportion of patients with MR ≤1+ was similar in both groups at discharge but diverged at 6 months, favoring PASCAL (83.7% vs 71.2%). Overall, patients with a smaller flail gap were significantly more likely to achieve MR ≤1+ at discharge (adjusted OR: 0.70; 95% CI: 0.50-0.99). Patients treated with PASCAL and those with a smaller flail gap were significantly more likely to sustain MR ≤1+ to 6 months (adjusted OR: 2.72 and 0.76; 95% CI: 1.08-6.89 and 0.60-0.98, respectively). CONCLUSIONS: The study used DMR-specific echocardiographic methodology for M-TEER reflecting current guidelines and advances in 3-dimensional echocardiography. Treatment with PASCAL and a smaller flail gap were significant factors in sustaining MR ≤1+ to 6 months. Results demonstrate that MR ≤1+ is an achievable benchmark for successful M-TEER. (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial [CLASP IID]; NCT03706833).


Subject(s)
Cardiac Catheterization , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Mitral Valve , Predictive Value of Tests , Recovery of Function , Severity of Illness Index , Humans , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/physiopathology , Male , Female , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve/physiopathology , Treatment Outcome , Cardiac Catheterization/instrumentation , Cardiac Catheterization/adverse effects , Aged , Risk Factors , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Time Factors , Aged, 80 and over , Heart Valve Prosthesis , Feasibility Studies , Risk Assessment , Prosthesis Design , Echocardiography, Three-Dimensional
6.
Sci Rep ; 13(1): 15340, 2023 09 15.
Article in English | MEDLINE | ID: mdl-37714924

ABSTRACT

Pressure recovery (PR) is essential part of the post stenotic fluid mechanics and depends on the ratio of EOA/AA, the effective aortic valve orifice area (EOA) and aortic cross-sectional area (AA). In patients with advanced ascending aortic aneurysm and mildly diseased aortic valves, the effect of AA on pressure recovery and corresponding functional aortic valve opening area (ELCO) was evaluated before and after valve-sparing surgery (Dacron graft implantation). 66 Patients with ascending aortic aneurysm (mean aortic diameter 57 +/- 10 mm) and aortic valve-sparing surgery (32 reimplantation technique (David), 34 remodeling technique (Yacoub)) were routinely investigated by Doppler echocardiography. Dacron graft with a diameter between 26 and 34 mm were implanted. EOA was significantly declined after surgery (3.4 +/- 0.8 vs. 2.6 +/- 0.9cm2; p < 0.001). Insertion of Dacron prosthesis resulted in a significant reduction of AA (26.7 +/- 10.2 vs. 6.8 +/- 1.1cm2; p < 0.001) with increased ratio of EOA/AA (0.14 +/- 0.05 vs. 0.40 +/- 0.1; p < 0.001) and pressure recovery index (PRI; 0.24 +/- 0.08 vs. 0.44 +/- 0.06; p < 0.0001). Despite reduction of EOA, ELCO (= EOA corrected for PR) increased from 4.0 +/- 1.1 to 5.0 +/- 3.1cm2 (p < 0.01) with reduction in transvalvular LV stroke work (1005 +/- 814 to 351 +/- 407 mmHg × ml, p < 0.001) after surgery. These effects were significantly better in patients with Yacoub technique than with the David operation. The hemodynamic findings demonstrate a valve-vessel interaction almost entirely caused by a marked reduction in the ascending AA with significant PR gain. The greater hemodynamic benefit of the Yacoub technique due to higher EOA values compared to the David technique was evident and may be of clinical relevance.


Subject(s)
Aorta, Thoracic , Aortic Valve , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Polyethylene Terephthalates , Catheters , Aorta/diagnostic imaging , Aorta/surgery
7.
Echocardiography ; 40(10): 1058-1067, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37638407

ABSTRACT

BACKGROUND: The importance of pulmonary artery pressure recovery (PR) in patients with Ross procedures in whom a homograft substitutes the resected pulmonary valve, is unknown. The aim of the study was to evaluate the occurrence and extent of PR in the pulmonary artery in 65 asymptomatic patients with pulmonary homograft after Ross surgery during rest and exercise. METHODS: Stress echocardiography was performed in 65 pulmonary homograft patients and 31 controls with native pulmonary valves up to 75 W. Right ventricular systolic pressure (RVSP), transvalvular flow, mean pressure gradient (Pmean ), valve resistance, and RV stroke work were determined in the exercise (max. 75 W) and recovery phases in increments of 25 W each. RESULTS: Pulmonary homografts demonstrated significantly elevated Pmean compared to controls at all stages. When considering pressure recovery (absolute and relative PR at rest 3.8 ± 1.8 mm Hg, 42.6 ± 7.2%, respectively) and transvalvular energy loss (EL; at rest 4.5 ± 4.3 mm Hg) the homograft hemodynamics reached the level of controls. In a subgroup of patients with tricuspid regurgitation, resting RVSP was the same in homograft patients and controls (21.3 ± 6.1 vs. 20.4 ± 6.3, p = .62), despite significant different Pmax values. CONCLUSIONS: Ross patients with pulmonary homograft showed systematically increased hemodynamic parameters compared to normal pulmonary valves. These differences were abolished when PR was considered for homograft patients. The equality of RVSP values at rest in both groups shows non-invasive evidence for PR in the pulmonary system after homograft implantation. Therefore, PR appears to be an important measure in calculating the actual hemodynamics in pulmonary homografts.

8.
JACC Case Rep ; 16: 101874, 2023 Jun 21.
Article in English | MEDLINE | ID: mdl-37396318

ABSTRACT

Transcatheter edge-to-edge repair (TEER) is the most widely used approach for tricuspid regurgitation in patients with prohibitive surgical risk. However, TEER might not be feasible in advanced tricuspid regurgitation. In such cases, a stepwise approach with initial annuloplasty and subsequent TEER can be a worthwhile alternative, which is reported in this series. (Level of Difficulty: Intermediate.).

SELECTION OF CITATIONS
SEARCH DETAIL
...