1.
Circ J ; 84(4): 636-641, 2020 03 25.
Article in English | MEDLINE | ID: mdl-32101814

ABSTRACT

BACKGROUND: The aim of this study was to evaluate the quality and diagnostic performance of virtual monochromatic images (VMI) obtained with dual-layer dual-energy computed tomography (DL-DECT) during indirect CT venography (CTV) for deep vein thrombosis (DVT).Methods and Results:This retrospective study was approved by the Institutional Review Board, which waived the requirement for informed consent. We retrospectively enrolled 45 patients who underwent CTV with DL-DECT, and VMI were retrospectively generated. We compared the venous attenuation, noise, contrast, and contrast-to-noise ratio (CNR) between VMI with the highest CNR and conventional CT on paired t-test. Furthermore, we compared the pooled area under the curve (AUC) of each technique with Delong's test in 34 patients who underwent color Doppler ultrasonography. The 40-keV VMI had the best CNR. The noise was significantly lower on 40-keV (9.7±2.5 HU) than on 120-kVp VMI (10.5±2.5 HU; P<0.01). The contrast (120 kVp, 38.2±15.3 HU vs. 40 keV, 131.6±43.6 HU) and CNR (120 kVp, 3.8±1.7 vs. 40 keV, 14.4±6.1) were significantly higher in 40-keV VMI than in 120-kVp VMI (P<0.01). Furthermore, the pooled AUC was significantly higher for 40-keV (0.84) than for 120-kVp VMI (0.78; P=0.03). CONCLUSIONS: In indirect CTV, 40-keV VMI obtained with DL-DECT offers better image quality and diagnostic performance for DVT than conventional CT.


Subject(s)
Computed Tomography Angiography , Phlebography , Venous Thrombosis/diagnostic imaging , Humans , Observer Variation , Predictive Value of Tests , Reproducibility of Results , Retrospective Studies , Ultrasonography, Doppler, Color
2.
J Comput Assist Tomogr ; 44(1): 78-82, 2020.
Article in English | MEDLINE | ID: mdl-31939886

ABSTRACT

OBJECTIVE: This study aimed to evaluate virtual monochromatic images (VMIs) obtained using dual-layer dual-energy computed tomography (CT) for breast carcinoma. METHODS: We retrospectively enrolled 28 patients with breast cancer who were pathologically diagnosed using dual-layer dual-energy CT. Virtual monochromatic images (40-200 keV) were generated. We compared CT number, image noise, contrast, and contrast-to-noise ratio (CNR) between VMIs with the highest CNR and conventional CT images. We performed qualitative image analysis between VMIs at optimized energy and conventional CT images. RESULTS: Image noise of VMIs was not significantly different from that of the conventional CT images. As the x-ray energy decreased, CNR increased. The 40-keV VMIs were highest CNR and higher than that of the conventional CT images. In qualitative image analysis, the 40-keV images were significantly higher than conventional CT images. CONCLUSION: Both qualitative and quantitative analyses showed that the image quality of VMIs at 40 keV was significantly higher than that of conventional CT images.


Subject(s)
Breast Neoplasms/diagnostic imaging , Radiography, Dual-Energy Scanned Projection/methods , Tomography, X-Ray Computed/methods , Adult , Aged , Aged, 80 and over , Female , Humans , Middle Aged , Radiographic Image Enhancement , Radiographic Image Interpretation, Computer-Assisted , Retrospective Studies , Signal-To-Noise Ratio
3.
J Radiat Res ; 60(3): 348-352, 2019 May 01.
Article in English | MEDLINE | ID: mdl-30864652

ABSTRACT

Intensity-modulated radiation therapy is being increasingly used to treat cervical esophageal cancer (CEC); however, delineating the gross tumor volume (GTV) accurately is essential for its successful treatment. The use of computed tomography (CT) images to determine the GTV produces a large degree of interobserver variation. In this study, we evaluated whether the use of [18F]-fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET)/CT fused images reduced interobserver variation, compared with CT images alone, to determine the GTV in patients with CEC. FDG-PET/CT scans were obtained for 10 patients with CEC, imaged positioned on a flat tabletop with a pillow. Five radiation oncologists independently defined the GTV for the primary tumors using routine clinical data; they contoured the GTV based on CT images (GTVCT), followed by contouring based on FDG-PET/CT fused images (GTVPET/CT). To determine the geometric observer variation, we calculated the conformality index (CI) from the ratio of the intersection of the GTVs to their union. The interobserver CI was compared using Wilcoxon's signed rank test. The mean (±SD) interobserver CIs of GTVCT and GTVPET/CT were 0.39 ± 0.15 and 0.58 ± 0.10, respectively (P = 0.005). Our results suggested that FDG-PET/CT images reduced interobserver variation when determining the GTV in patients with CEC. FDG-PET/CT may increase the consistency of the radiographically determined GTV in patients with CEC.


Subject(s)
Esophageal Neoplasms/diagnostic imaging , Esophageal Neoplasms/pathology , Fluorodeoxyglucose F18/chemistry , Positron Emission Tomography Computed Tomography , Tumor Burden , Aged , Female , Humans , Male , Middle Aged , Observer Variation
4.
Eur Radiol ; 29(4): 2009-2016, 2019 Apr.
Article in English | MEDLINE | ID: mdl-30255255

ABSTRACT

OBJECTIVES: To evaluate the effect of a spiral tube on contrast enhancement in the hepatic arterial phase (HAP) of gadoxetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI). METHODS: In this retrospective study, we observed 104 patients who underwent dynamic MRI of the liver between October 2017 and December 2017. Three Gd-EOB-DTPA injection protocols were compared: (A) conventional method (undiluted Gd-EOB-DTPA, injection rate 1 ml/s, n = 36); (B) spiral dilution method (1:1 diluted Gd-EOB-DTPA with saline [off-label], injection rate 2 ml/s via spiral tube, n = 38); (C) spiral-flushed method (undiluted Gd-EOB-DTPA, injection rate 1 ml/s via spiral tube, n = 30). We regarded protocol-A as a control. The signal-to-noise ratio (SNR) of the abdominal aorta was calculated using arterial phase images. Image contrast and artefacts were evaluated by two board-certified radiologists, using a four-point scale. Statistical analyses included Dunnett's test, the Kruskal-Wallis test and the Steel test. RESULTS: The SNR of the aorta was significantly higher with protocol-C (25.4 ± 8.8) than protocol-A (20.8 ± 5.4, p = 0.01). There was no significant difference in SNR between protocols A and B (p = 0.47). The contrast score of protocol-C was significantly higher than that of protocol-A (p = 0.0019). There was no significant difference in contrast score between protocols A and B (p = 0.50). There was no significant difference in artefacts among the three protocols (p = 0.96). CONCLUSIONS: Use of a spiral tube with a slow injection protocol contributed to improved aortic contrast enhancement in the HAP of GD-EOB-DTPA-enhanced hepatic MRI. KEY POINTS: • Gadoxetic acid shows weaker arterial enhancement at recommended doses, compared with nonspecific gadolinium agents; selection of an appropriate injection protocol is important. • A spiral flow-generating tube improves the transport efficiency of the contrast media, and increases the signal-to-noise ratio of the aorta in hepatic arterial phase. • A spiral flow-generating tube does not contribute to artefact reduction in hepatic arterial phase.


Subject(s)
Aorta, Abdominal/diagnostic imaging , Gadolinium DTPA/pharmacology , Imaging, Three-Dimensional , Liver Diseases/diagnosis , Magnetic Resonance Imaging/methods , Adult , Aged , Aged, 80 and over , Artifacts , Contrast Media/pharmacology , Female , Hepatic Artery/pathology , Humans , Male , Middle Aged , Retrospective Studies , Saline Solution/pharmacology
5.
Eur Radiol ; 29(6): 2837-2847, 2019 Jun.
Article in English | MEDLINE | ID: mdl-30377793

ABSTRACT

OBJECTIVES: To evaluate the image quality of virtual-monoenergetic-imaging (VMI) from dual-layer dual-energy CT (DLCT) for the assessment of hypovascular liver metastases and its effect on lesion detectability. METHODS: Eighty-one patients with hypovascular-liver-metastases undergoing portal-venous-phase abdominal DLCT were included. Polyenergetic-images (PEI) and VMI at 40-200 keV (VMI40-200, 10-keV interval) were reconstructed. Image noise, tumor-to-liver contrast, and contrast-to-noise ratio (CNR) of hepatic parenchyma and metastatic nodules (n = 288) were measured to determine the optimal monoenergetic levels. Two radiologists independently and subjectively assessed the image quality (image contrast, image noise, and diagnostic confidence) of PEI and optimal VMI on 5-point scales to determine the best energy. For 38 patients having up to 10 metastases each with diameters < 25 mm (153 lesions), we compared blindly assessed lesion detectability and conspicuity between PEI and VMI at the best energy. RESULTS: Image noise of VMI40-200 was consistently lower than that of PEI (p < 0.01). Tumor-to-liver contrast and CNR increased as the energy decreased with CNR at VMI40-70 being higher than that observed on PEI (p < 0.01). The highest subjective score for diagnostic confidence was assigned at VMI40 followed by VMI50-70, all of which were significantly better than that of PEI (p < 0.01, kappa = 0.75). Lesion detectability at VMI40 was significantly superior to PEI, especially for lesions with diameters of < 10 mm (p < 0.01, kappa ≥ 0.6). CONCLUSIONS: VMI40-70 provided a better subjective and objective image quality for the evaluation of hypovascular liver metastases, and the lesion detectability was improved with use of VMI40 compared with conventional PEI. KEY POINTS: • DLCT-VMI at 40-70 keV provides a superior subjective and objective image quality compared with conventional PEI for the assessment of hypovascular hepatic metastases during portal venous phase. • Tumor-to-liver contrast and CNR of hypovascular hepatic metastases was maximized at 40 keV without a relevant increase in the image noise. • VMI at 40 keV yields a superior lesion detectability, especially for small (< 1 cm) metastatic nodules compared with conventional PEI.


Subject(s)
Liver Neoplasms/diagnosis , Radiography, Dual-Energy Scanned Projection/methods , Tomography, X-Ray Computed/methods , Female , Humans , Image Enhancement/methods , Liver Neoplasms/secondary , Male , Middle Aged , Neoplasm Metastasis , Reproducibility of Results , Retrospective Studies , Signal-To-Noise Ratio , Young Adult
6.
J Radiat Res ; 59(6): 794-799, 2018 Nov 01.
Article in English | MEDLINE | ID: mdl-30247674

ABSTRACT

The ability of topical metal-containing agents (MCAs) to enhance radiation dermatitis remains controversial. In the present study, we evaluated increases in surface doses associated with topical agents at different application thicknesses and with MCAs versus non-metal containing agents (NMCAs). We assessed two clinically available MCAs, zinc oxide ointment (ZOO) and silver sulfadiazine cream (SSDC), and eight NMCAs. Surface doses were measured using a Markus chamber placed on a polystyrene phantom. To evaluate the role of application thickness, each agent was applied to the chamber in oil-slick (<0.1-mm), 1-mm and 5-mm layers prior to irradiation of a 10 × 10 cm field with 4-, 6- and 10-MV X-ray beams. The surface dose enhancement ratio (SDER) was calculated as the ratio of the surface dose with an agent to the dose without an agent. The SDER values for the eight NMCAs, ZOO and SSDC at an oil-slick thickness were 101.6-104.6% (mean: 103.3%), 104.5% and 105.0%, respectively, using a 6-MV X-ray beam. The corresponding values at a 1-mm thickness were 196.8-237.8% (mean: 215.7%), 229.3% and 201.4%, respectively, and those at a 5-mm thickness were 342.2-382.4% (mean: 357.9%), 357.1% and 352.6%, respectively. A similar tendency was found using 4- and 10-MV X-ray beams. The lack of a significant difference in surface dose enhancement between MCAs and NMCAs, particularly when applied in oil-slick layers, suggests that MCAs do not need to be avoided or applied in a restricted manner during radiotherapy for dosimetric reasons.


Subject(s)
Metals/pharmacology , Radiotherapy Dosage , Administration, Topical , Dose-Response Relationship, Radiation , Humans , Phantoms, Imaging
7.
Jpn J Radiol ; 36(11): 641-648, 2018 Nov.
Article in English | MEDLINE | ID: mdl-30145659

ABSTRACT

Earthquakes are unpredictable and inevitable disasters, causing various earthquake-related disorders. Medical imaging, including digital radiography, computed tomography, and magnetic resonance imaging, plays a key role in the evaluation of earthquake-related disorders. We here demonstrate the concept of diagnostic imaging after a massive earthquake and review the common imaging features of various disorders in casualties and evacuees. This summary of imaging features can facilitate the diagnosis of various earthquake-related disorders and promote judicious therapy planning.


Subject(s)
Diagnostic Imaging/methods , Earthquakes , Wounds and Injuries/diagnostic imaging , Emergencies , Humans
8.
Case Rep Orthop ; 2018: 1468929, 2018.
Article in English | MEDLINE | ID: mdl-29686915

ABSTRACT

We describe a case of lumbar stenosis in which retrospective spectral analysis using dual-layer spectral detector computed tomography (CT) had the ability to expand the evaluable region in the spinal canal. Spinal canal stenosis is a common condition whose symptoms (such as lower back and leg pain with walking) deteriorate the quality of life. Generally, magnetic resonance imaging (MRI) and CT myelography are performed to diagnose canal stenosis. Dual-layer spectral detector CT can yield virtual monochromatic imaging and retrospective on-demand spectral analysis without a prescan setting. Spectral analysis could expand the evaluable region in the spinal canal for increasing the contrast enhancement in the canal.

9.
J Comput Assist Tomogr ; 41(5): 811-816, 2017.
Article in English | MEDLINE | ID: mdl-28448403

ABSTRACT

OBJECTIVES: The objective of this study was to evaluate the use of 80-kVp scans with knowledge-based iterative model reconstruction (IMR) for computed tomography venography (CTV). METHODS: This prospective study received institutional review board approval; a previous informed consent was obtained from all participants. We enrolled 30 patients with suspected deep venous thrombosis or pulmonary embolism who were to undergo 80-kVp CTV studies. The images were reconstructed with filtered back projection (FBP), hybrid iterative reconstruction (HIR), and IMR. The venous attenuation, image noise, and contrast-to-noise ratio at the iliac, femoral, and popliteal veins were compared on FBP, HIR, and IMR images. We performed qualitative image analysis (image noise, image contrast, image sharpness, streak artifacts, and overall image quality) of the 3 reconstruction methods and measured their reconstruction times. RESULTS: There was no significant difference in venous attenuation among the 3 reconstruction methods (P > 0.05). On IMR images, the image noise was lowest at all 3 venous locations, and the contrast-to-noise ratio was highest. Qualitative evaluation scores were also highest for IMR images. The reconstruction time for FBP, HIR, and IMR imaging was 25.4 ± 1.9 seconds, 43.3 ± 3.3 seconds, and 78.7 ± 6.0 seconds, respectively. CONCLUSIONS: At clinically acceptable reconstruction times, 80-kVp CTV using the IMR technique yielded better qualitative and quantitative image quality than HIR and FBP.


Subject(s)
Algorithms , Image Processing, Computer-Assisted/methods , Pulmonary Embolism/diagnostic imaging , Radiation Dosage , Tomography, X-Ray Computed/instrumentation , Venous Thrombosis/diagnostic imaging , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Prospective Studies , Radiographic Image Interpretation, Computer-Assisted/methods
10.
Eur Radiol ; 27(9): 3600-3608, 2017 Sep.
Article in English | MEDLINE | ID: mdl-28289941

ABSTRACT

PURPOSE: To develop a prediction model to distinguish between transition zone (TZ) cancers and benign prostatic hyperplasia (BPH) on multi-parametric prostate magnetic resonance imaging (mp-MRI). MATERIALS AND METHODS: This retrospective study enrolled 60 patients with either BPH or TZ cancer, who had undergone 3 T-MRI. We generated ten parameters for T2-weighted images (T2WI), diffusion-weighted images (DWI) and dynamic MRI. Using a t-test and multivariate logistic regression (LR) analysis to evaluate the parameters' accuracy, we developed LR models. We calculated the area under the receiver operating characteristic curve (ROC) of LR models by a leave-one-out cross-validation procedure, and the LR model's performance was compared with radiologists' performance with their opinion and with the Prostate Imaging Reporting and Data System (Pi-RADS v2) score. RESULTS: Multivariate LR analysis showed that only standardized T2WI signal and mean apparent diffusion coefficient (ADC) maintained their independent values (P < 0.001). The validation analysis showed that the AUC of the final LR model was comparable to that of board-certified radiologists, and superior to that of Pi-RADS scores. CONCLUSION: A standardized T2WI and mean ADC were independent factors for distinguishing between BPH and TZ cancer. The performance of the LR model was comparable to that of experienced radiologists. KEY POINTS: • It is difficult to diagnose transition zone (TZ) cancer. • We performed quantitative image analysis in multi-parametric MRI. • Standardized-T2WI and mean-ADC were independent factors for diagnosing TZ cancer. • We developed logistic-regression analysis to diagnose TZ cancer accurately. • The performance of the logistic-regression analysis was higher than PIRADSv2.


Subject(s)
Prostatic Hyperplasia/diagnostic imaging , Prostatic Neoplasms/diagnostic imaging , Aged , Aged, 80 and over , Diagnosis, Differential , Diffusion Magnetic Resonance Imaging/methods , Humans , Image Interpretation, Computer-Assisted/methods , Logistic Models , Machine Learning , Magnetic Resonance Imaging/methods , Male , Middle Aged , Prostatectomy , Prostatic Hyperplasia/pathology , Prostatic Hyperplasia/surgery , Prostatic Neoplasms/pathology , Prostatic Neoplasms/surgery , ROC Curve , Retrospective Studies , Sensitivity and Specificity
11.
Radiology ; 284(1): 153-160, 2017 07.
Article in English | MEDLINE | ID: mdl-28156203

ABSTRACT

Purpose To evaluate the image quality and interobserver reproducibility of unenhanced lumbar spinal computed tomography (CT) images reconstructed with iterative model reconstruction (IMR). Materials and Methods This prospective study was approved by the local ethics committee, and written informed consent was obtained from all patients. The study included 34 patients scanned with unenhanced CT and magnetic resonance (MR) imaging for lumbar canal spinal stenosis. The CT images were reconstructed with filtered back projection (FBP), hybrid iterative reconstruction (HIR), and IMR. Image noise and contrast-to-noise ratio (CNR) were compared among the three reconstruction techniques with the repeated one-way analysis of variance. The interobserver agreement of the dural sac on all CT image sets and T2-weighted images was also compared. Qualitative analysis of the three reconstruction techniques was performed by using Friedman test and the Wilcoxon signed-rank test with Holm correction. Results The image noise of IMR was significantly lower than that of FBP or HIR (P < .001 and P < .001). Pearson correlation analysis showed that the highest correlation coefficient with interobserver agreement was with IMR (r = 0.98) followed by MR imaging (r = 0.88), FBP (r = 0.41), and HIR (r = 0.33). It also showed that the narrowest Bland-Altman limit of agreement was achieved with IMR followed by MR imaging, FBP, and HIR. The qualitative image score using IMR was significantly higher than that using FBP or HIR (P < .001 and P < .001). Conclusion IMR offers excellent noise reduction, higher interobserver reproducibility of canal stenosis, and improved image quality compared with FBP and HIR. © RSNA, 2017 Online supplemental material is available for this article.


Subject(s)
Intervertebral Disc Displacement/diagnostic imaging , Lumbar Vertebrae/diagnostic imaging , Spinal Stenosis/diagnostic imaging , Tomography, X-Ray Computed/methods , Adolescent , Adult , Aged , Female , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Models, Theoretical , Radiographic Image Interpretation, Computer-Assisted , Reproducibility of Results