Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Sensors (Basel) ; 23(14)2023 Jul 18.
Article in English | MEDLINE | ID: mdl-37514778

ABSTRACT

Not long ago, hearables paved the way for biosensing, fitness, and healthcare monitoring. Smart earbuds today are not only producing sound but also monitoring vital signs. Reliable determination of cardiovascular and pulmonary system information can explore the use of hearables for physiological monitoring. Recent research shows that photoplethysmography (PPG) signals not only contain details on oxygen saturation level (SPO2) but also carry more physiological information including pulse rate, respiration rate, blood pressure, and arterial-related information. The analysis of the PPG signal from the ear has proven to be reliable and accurate in the research setting. (1) Background: The present integrative review explores the existing literature on an in-ear PPG signal and its application. This review aims to identify the current technology and usage of in-ear PPG and existing evidence on in-ear PPG in physiological monitoring. This review also analyzes in-ear (PPG) measurement configuration and principle, waveform characteristics, processing technology, and feature extraction characteristics. (2) Methods: We performed a comprehensive search to discover relevant in-ear PPG articles published until December 2022. The following electronic databases: Institute of Electrical and Electronics Engineers (IEEE), ScienceDirect, Scopus, Web of Science, and PubMed were utilized to conduct the studies addressing the evidence of in-ear PPG in physiological monitoring. (3) Results: Fourteen studies were identified but nine studies were finalized. Eight studies were on different principles and configurations of hearable PPG, and eight studies were on processing technology and feature extraction and its evidence in in-ear physiological monitoring. We also highlighted the limitations and challenges of using in-ear PPG in physiological monitoring. (4) Conclusions: The available evidence has revealed the future of in-ear PPG in physiological monitoring. We have also analyzed the potential limitation and challenges that in-ear PPG will face in processing the signal.


Subject(s)
Arteries , Photoplethysmography , Monitoring, Physiologic , Blood Pressure , Respiratory Rate , Heart Rate , Signal Processing, Computer-Assisted
2.
Sensors (Basel) ; 23(12)2023 Jun 12.
Article in English | MEDLINE | ID: mdl-37420692

ABSTRACT

Data gathering in wireless sensor networks (WSNs) is vital for deploying and enabling WSNs with the Internet of Things (IoTs). In various applications, the network is deployed in a large-scale area, which affects the efficiency of the data collection, and the network is subject to multiple attacks that impact the reliability of the collected data. Hence, data collection should consider trust in sources and routing nodes. This makes trust an additional optimization objective of the data gathering in addition to energy consumption, traveling time, and cost. Joint optimization of the goals requires conducting multiobjective optimization. This article proposes a modified social class multiobjective particle swarm optimization (SC-MOPSO) method. The modified SC-MOPSO method is featured by application-dependent operators named interclass operators. In addition, it includes solution generation, adding and deleting rendezvous points, and moving to the upper and lower class. Considering that SC-MOPSO provides a set of nondominated solutions as a Pareto front, we employed one of the multicriteria decision-making (MCDM) methods, i.e., simple additive sum (SAW), for selecting one of the solutions from the Pareto front. The results show that both SC-MOPSO and SAW are superior in terms of domination. The set coverage of SC-MOPSO is 0.06 dominant over NSGA-II compared with only a mastery of 0.04 of NSGA-II over SC-MOPSO. At the same time, it showed competitive performance with NSGA-III.


Subject(s)
Algorithms , Awareness , Data Collection , Reproducibility of Results
3.
Nanomaterials (Basel) ; 13(5)2023 Feb 24.
Article in English | MEDLINE | ID: mdl-36903730

ABSTRACT

Flexible sensors have been extensively employed in wearable technologies for physiological monitoring given the technological advancement in recent years. Conventional sensors made of silicon or glass substrates may be limited by their rigid structures, bulkiness, and incapability for continuous monitoring of vital signs, such as blood pressure (BP). Two-dimensional (2D) nanomaterials have received considerable attention in the fabrication of flexible sensors due to their large surface-area-to-volume ratio, high electrical conductivity, cost effectiveness, flexibility, and light weight. This review discusses the transduction mechanisms, namely, piezoelectric, capacitive, piezoresistive, and triboelectric, of flexible sensors. Several 2D nanomaterials used as sensing elements for flexible BP sensors are reviewed in terms of their mechanisms, materials, and sensing performance. Previous works on wearable BP sensors are presented, including epidermal patches, electronic tattoos, and commercialized BP patches. Finally, the challenges and future outlook of this emerging technology are addressed for non-invasive and continuous BP monitoring.

4.
Cardiovasc Diabetol ; 22(1): 13, 2023 01 19.
Article in English | MEDLINE | ID: mdl-36658644

ABSTRACT

Prediction model has been the focus of studies since the last century in the diagnosis and prognosis of various diseases. With the advancement in computational technology, machine learning (ML) has become the widely used tool to develop a prediction model. This review is to investigate the current development of prediction model for the risk of cardiovascular disease (CVD) among type 2 diabetes (T2DM) patients using machine learning. A systematic search on Scopus and Web of Science (WoS) was conducted to look for relevant articles based on the research question. The risk of bias (ROB) for all articles were assessed based on the Prediction model Risk of Bias Assessment Tool (PROBAST) statement. Neural network with 76.6% precision, 88.06% sensitivity, and area under the curve (AUC) of 0.91 was found to be the most reliable algorithm in developing prediction model for cardiovascular disease among type 2 diabetes patients. The overall concern of applicability of all included studies is low. While two out of 10 studies were shown to have high ROB, another studies ROB are unknown due to the lack of information. The adherence to reporting standards was conducted based on the Transparent Reporting of a multivariable prediction model for Individual Prognosis or Diagnosis (TRIPOD) standard where the overall score is 53.75%. It is highly recommended that future model development should adhere to the PROBAST and TRIPOD assessment to reduce the risk of bias and ensure its applicability in clinical settings. Potential lipid peroxidation marker is also recommended in future cardiovascular disease prediction model to improve overall model applicability.


Subject(s)
Cardiovascular Diseases , Diabetes Mellitus, Type 2 , Humans , Diabetes Mellitus, Type 2/complications , Diabetes Mellitus, Type 2/diagnosis , Diabetes Mellitus, Type 2/epidemiology , Cardiovascular Diseases/diagnosis , Cardiovascular Diseases/epidemiology , Cardiovascular Diseases/etiology , Prognosis , Machine Learning
5.
Sensors (Basel) ; 22(19)2022 Sep 25.
Article in English | MEDLINE | ID: mdl-36236368

ABSTRACT

Epilepsy is a chronic neurological disorder caused by abnormal neuronal activity that is diagnosed visually by analyzing electroencephalography (EEG) signals. BACKGROUND: Surgical operations are the only option for epilepsy treatment when patients are refractory to treatment, which highlights the role of classifying focal and generalized epilepsy syndrome. Therefore, developing a model to be used for diagnosing focal and generalized epilepsy automatically is important. METHODS: A classification model based on longitudinal bipolar montage (LB), discrete wavelet transform (DWT), feature extraction techniques, and statistical analysis in feature selection for RNN combined with long short-term memory (LSTM) is proposed in this work for identifying epilepsy. Initially, normal and epileptic LB channels were decomposed into three levels, and 15 various features were extracted. The selected features were extracted from each segment of the signals and fed into LSTM for the classification approach. RESULTS: The proposed algorithm achieved a 96.1% accuracy, a 96.8% sensitivity, and a 97.4% specificity in distinguishing normal subjects from subjects with epilepsy. This optimal model was used to analyze the channels of subjects with focal and generalized epilepsy for diagnosing purposes, relying on statistical parameters. CONCLUSIONS: The proposed approach is promising, as it can be used to detect epilepsy with satisfactory classification performance and diagnose focal and generalized epilepsy.


Subject(s)
Epilepsy, Generalized , Epilepsy , Algorithms , Electroencephalography/methods , Epilepsy/diagnosis , Epilepsy, Generalized/diagnosis , Humans , Signal Processing, Computer-Assisted , Wavelet Analysis
6.
Sensors (Basel) ; 22(16)2022 Aug 18.
Article in English | MEDLINE | ID: mdl-36015956

ABSTRACT

Blood pressure (BP) monitoring can be performed either invasively via arterial catheterization or non-invasively through a cuff sphygmomanometer. However, for conscious individuals, traditional cuff-based BP monitoring devices are often uncomfortable, intermittent, and impractical for frequent measurements. Continuous and non-invasive BP (NIBP) monitoring is currently gaining attention in the human health monitoring area due to its promising potentials in assessing the health status of an individual, enabled by machine learning (ML), for various purposes such as early prediction of disease and intervention treatment. This review presents the development of a non-invasive BP measuring tool called sphygmomanometer in brief, summarizes state-of-the-art NIBP sensors, and identifies extended works on continuous NIBP monitoring using commercial devices. Moreover, the NIBP predictive techniques including pulse arrival time, pulse transit time, pulse wave velocity, and ML are elaborated on the basis of bio-signals acquisition from these sensors. Additionally, the different BP values (systolic BP, diastolic BP, mean arterial pressure) of the various ML models adopted in several reported studies are compared in terms of the international validation standards developed by the Advancement of Medical Instrumentation (AAMI) and the British Hypertension Society (BHS) for clinically-approved BP monitors. Finally, several challenges and possible solutions for the implementation and realization of continuous NIBP technology are addressed.


Subject(s)
Blood Pressure Determination , Pulse Wave Analysis , Blood Pressure/physiology , Humans , Machine Learning , Pulse Wave Analysis/methods , Sphygmomanometers
7.
J Med Eng Technol ; 46(7): 567-589, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35801952

ABSTRACT

Blood pressure (BP) is a vital health parameter that varies throughout the day. As a single reading of high BP may not indicate hypertension, continuous monitoring of BP is usually recommended by medical doctors to confirm the diagnosis of hypertension. In the last few decades, researchers have investigated cuff-less and continuous BP measurements based on pulse transit time (PTT). The main purpose of this research is to develop an autoregressive (ARX) system identification (SI)-based PTT calculation model using two PPG signals acquired from carotid and toe. The signals were recorded from 65 subjects with an age range between 20 and 60 years. The results of the study have been validated in two stages. The first validation comprised the estimated BP from PTT using SI compared to the measured BP using the cuff-based method for all subjects. The results of the estimated BP using the proposed method compared to the measured BP obtained using the standard BP cuff measurement method are highly correlated to both systolic blood pressure (R2 = 0.8132) and diastolic blood pressure (R2 = 0.8357). The second validation consisted of comparing PTT values using system identification to the results of the PTT derived from the ECG-PPG method. The results showed that both methods are highly correlated (R2 = 0.7808), and there is no significant difference between them (p < 0.05) with a slightly better PTT estimation related to DBP in the proposed method. Our results have proven that the PTT obtained from the carotid PPG and toe PPG using the system identification approach yielded SBP and DBP estimations that are consistent with the values of the conventional BP cuff method. The newly proposed method has the advantage of being cuff-less and able to provide continuous BP measurements.


Subject(s)
Hypertension , Photoplethysmography , Adult , Blood Pressure/physiology , Blood Pressure Determination/methods , Humans , Hypertension/diagnosis , Middle Aged , Photoplethysmography/methods , Pulse Wave Analysis/methods , Toes , Young Adult
8.
Front Public Health ; 10: 920946, 2022.
Article in English | MEDLINE | ID: mdl-35844894

ABSTRACT

Fiducial points of photoplethysmogram (PPG), first derivative PPG (VPG), and second derivative PPG (APG) are essential in extracting numerous parameters to diagnose cardiovascular disease. However, the fiducial points were usually detected using complex mathematical algorithms. Inflection points from derivatives waveforms are not thoroughly studied, whereas they can significantly assist in peak detection. This study is performed to investigate the derivative waveforms of PPG and use them to detect the important peaks of PPG, VPG, and APG. PPGs with different morphologies from 43 ischemic heart disease subjects are analyzed. Inflection points of the derivative waveforms up to the fourth level are observed, and consistent information (derivative markers) is used to detect the fiducial points of PPG, VPG, and APG with proper sequence. Moving average filter and simple thresholding techniques are applied to detect the primary points in VPG and the third derivative waveform. A total of twelve out of twenty derivative markers are found reliable in detecting fiducial points of two common types of PPG. Systolic peaks are accurately detected with 99.64% sensitivity and 99.38% positive predictivity using the 43 IHD dataset and Complex System Laboratory (CSL) Pulse Oximetry Artifact Labels database. The study has introduced the fourth derivative PPG waveform with four main points, which are significantly valuable for detecting the fiducial points of PPG, VPG, and APG.


Subject(s)
Artifacts , Photoplethysmography , Algorithms , Humans , Photoplethysmography/methods
9.
Technol Health Care ; 24(4): 591-7, 2016 Jul 27.
Article in English | MEDLINE | ID: mdl-26890231

ABSTRACT

BACKGROUND: Among vital signs of acutely ill hospital patients, respiratory rate (RR) is a highly accurate predictor of health deterioration. OBJECTIVE: This study proposes a system that consists of a passive and non-invasive single-lead electrocardiogram (ECG) acquisition module and an ECG-derived respiratory (EDR) algorithm in the working prototype of a mobile application. METHOD: Before estimating RR that produces the EDR rate, ECG signals were evaluated based on the signal quality index (SQI). The SQI algorithm was validated quantitatively using the PhysioNet/Computing in Cardiology Challenge 2011 training data set. The RR extraction algorithm was validated by adopting 40 MIT PhysioNet Multiparameter Intelligent Monitoring in Intensive Care II data set. RESULTS: The estimated RR showed a mean absolute error (MAE) of 1.4 compared with the ``gold standard'' RR. The proposed system was used to record 20 ECGs of healthy subjects and obtained the estimated RR with MAE of 0.7 bpm. CONCLUSION: Results indicate that the proposed hardware and algorithm could replace the manual counting method, uncomfortable nasal airflow sensor, chest band, and impedance pneumotachography often used in hospitals. The system also takes advantage of the prevalence of smartphone usage and increase the monitoring frequency of the current ECG of patients with critical illnesses.


Subject(s)
Electrocardiography/instrumentation , Mobile Applications , Respiratory Rate , Signal Processing, Computer-Assisted/instrumentation , Algorithms , Female , Heart Rate , Humans , Male
SELECTION OF CITATIONS
SEARCH DETAIL
...