Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Curr Oncol ; 27(6): e537-e546, 2020 12.
Article in English | MEDLINE | ID: mdl-33380868

ABSTRACT

Background: Treatment of hepatic metastases from neuroendocrine tumours improves survival and symptom relief. Hepatic arterial embolotherapy techniques include transarterial chemoembolization (tace) and bland embolization (tae). The relative efficacy of the techniques is controversial. The purpose of the present study was to use a meta-analysis and systematic review to compare tace with tae in the treatment of hepatic metastases. Methods: A literature search identified studies comparing tace and tae for treatment of hepatic metastases. Outcomes of interest included overall survival (os), progression-free survival (pfs), radiographic response, complications, and symptom control. The hazard ratios (hrs) and odds ratios (ors) were estimated and pooled. Results: Eight studies and 504 patients were included. No statistically significant differences between tace and tae were observed for os at 1, 2, and 5 years or for hrs [1-year or: 0.72; 95% confidence interval (ci): 0.27 to 1.94; p < 0.52; 2-year or: 0.69; 95% ci: 0.43 to 1.11; p < 0.12; 5-year or: 0.91; 95% ci: 0.37 to 2.24; p < 0.85; hr: 0.96; 95% ci: 0.73 to 1.24; p < 0.74]. No statistically significant differences between tace and tae were observed for pfs at 1, 2, and 5 years or for hrs (1-year or: 0.71; 95% ci: 0.38 to 1.55; p < 0.30; 2-year or: 0.83; 95% ci: 0.33 to 2.06; p < 0.69; 5-year or: 0. 91; 95% ci: 0.37 to 2.24; p < 0.85; hr: 0.99-1.74; 95% ci: 0.74 to 1.73; p < 0.97). Both techniques are safe and effective for symptom control. Conclusions: No statistically significant differences between tace and tae were observed for os and pfs.


Subject(s)
Carcinoma, Hepatocellular , Chemoembolization, Therapeutic , Liver Neoplasms , Neuroendocrine Tumors , Carcinoma, Hepatocellular/therapy , Humans , Liver Neoplasms/therapy , Neuroendocrine Tumors/therapy , Treatment Outcome
2.
Cardiovasc Intervent Radiol ; 42(1): 116-120, 2019 Jan.
Article in English | MEDLINE | ID: mdl-30135977

ABSTRACT

INTRODUCTION: Pulled or dislodged gastrostomy catheters represent a common complication associated with percutaneous gastrostomy and are a common cause of recurrent visits in patients with altered mental status. We intended to perform an experiment to compare the pull forces required to dislodge different commonly used gastrostomy catheters. MATERIALS AND METHODS: We used a digital force gauge device to measure the pull forces required to dislodge three types of 20 French gastrostomy catheters in double-layer skin models. These included the Flow 20 Pull Method (Cook Medical, Bloomington, IN, USA), Entuit Gastrostomy BR Balloon Retention feeding tube (Cook Medical, Bloomington, IN, USA), and Ponsky Non-Balloon Replacement Gastrostomy Tube (CR Bard Inc, Salt Lake City, Utah, USA). The catheters were inserted into the skin model using the same technique as would be utilized in a patient. RESULTS: The mean forces measured to dislodge the per-oral Flow 20 Pull Method, Entuit Thrive Balloon Retention, and button-type retention Ponsky replacement catheters were 35.6, 22.8, and 20.6 Newtons, respectively. The pull method per-oral gastrostomy catheter required significantly more pull force to dislodge than both the Ponsky button-type retention catheter and the Entuit balloon retention catheters. There was no significant difference in the pull force required to dislodge the Ponsky replacement catheter and the Entuit balloon retention catheter. CONCLUSIONS: Per-oral image-guided gastrostomy with pull-method button-type retention catheters may be the ideal choice in patients at high risk of tube dislodgment.


Subject(s)
Catheters , Device Removal/instrumentation , Equipment Design , Gastrostomy/instrumentation , Models, Biological , Female , Gastrostomy/methods , Humans , Male , Pressure , Recurrence , Skin
3.
Neuroradiology ; 56(1): 15-23, 2014 Jan.
Article in English | MEDLINE | ID: mdl-24212333

ABSTRACT

INTRODUCTION: Filling defects at the internal carotid artery (ICA) origin in the work-up of stroke or transient ischemic attack may be an ulcerated plaque or free-floating thrombus (FFT). This may be challenging to distinguish, as they can appear morphologically similar. This is an important distinction as FFT can potentially embolize distally, and its management differs. We describe a series of patients with suspected FFT and evaluate its imaging appearance, clinical features, and evolution with therapy. METHODS: Between 2008 and 2013, we prospectively collected consecutive patients with proximal ICA filling defects in the axial plane surrounded by contrast on CT/MR angiography. We defined FFT as a filling defect that resolved on follow-up imaging. We assessed the cranial-caudal dimension of the filling defect and receiver operating characteristics to identify clinical and radiological variables that distinguished FFT from complex ulcerated plaque. RESULTS: Intraluminal filling defects were identified in 32 patients. Filling defects and resolved or decreased in 25 patients (78 %) and felt to be FFT; there was no change in 7 (22 %). Resolved defects and those that decreased in size extended more cranially than those that remained unchanged: 7.3 mm (4.2-15.9) versus 3.1 mm (2.7-3.7; p = 0.0038). Receiver operating characteristic analysis established a threshold of 3.8 mm (filling defect length), sensitivity of 88 %, specificity of 86 %, and area under the curve of 0.86 (p < 0.0001) for distinguishing FFT from plaque. CONCLUSION: Filling defects in the proximal ICA extending cranially >3.8 mm were more likely to be FFT than complex ulcerated plaque. Further studies evaluating filling defect length as a predictor for FFT are warranted.


Subject(s)
Carotid Artery Thrombosis/diagnosis , Carotid Stenosis/diagnosis , Magnetic Resonance Angiography/methods , Stroke/diagnosis , Aged , Carotid Artery Thrombosis/complications , Carotid Stenosis/complications , Female , Humans , Male , Middle Aged , Observer Variation , Prognosis , Reproducibility of Results , Sensitivity and Specificity , Stroke/etiology , Tomography, X-Ray Computed/methods
4.
Eur J Clin Microbiol Infect Dis ; 31(11): 3223-9, 2012 Nov.
Article in English | MEDLINE | ID: mdl-22790538

ABSTRACT

We aimed to characterize the vancomycin genotype/phenotype, carriage of putative virulence genes, and genetic relatedness of Enterococcus faecium isolates in Saudi Arabia. E. faecium isolated from inpatients at our medical center were studied. Sensitivity to ampicillin, linezolid, teicoplanin, quinupristin/dalfopristin, tetracycline, and ciprofloxacin was determined. The presence of van genes and virulence genes for aggregation substance (Asa-1), enterococcal surface proteins (esp), cytolysin (cylA, cylL, cylM), gelatinase (gelE), E. faecium endocarditis antigen (EfaA( fm )), hyaluronidase (hyl), and collagen adhesion (Ace) was assessed. Genetic relatedness was determined by pulsed-field gel electrophoresis (PFGE). Twenty-nine E. faecium isolates were obtained and the majority of isolates (n/N = 22/29) were from stool specimens. PFGE analysis identified eight pulsotypes (A-H) based on 80 % similarities. Isolates were represented in five major pulsotypes: type A (n = 5), type B (n = 3), type D (n = 6), type E (n = 5), and type F (n = 7). All isolates were vanA gene-positive. Thirteen isolates had vanA(+)/vanB(+) genotype. Of these, ten exhibited a vanB phenotype and three had a vanA phenotype. Eight isolates with vanA(+)/vanB(-) genotype exhibited vanB phenotype. Six of these eight isolates belonged to the same pulsotype. All isolates were positive for gelE, esp, and EfaA( fm ) genes. Five were CylA-positive and 24 had the hyl genes. Of the eight isolates harboring a combination of gelE, esp, EfaA( fm ), and hyl genes, five showed vanB phenotype-vanA genotype incongruence. This is the first report of vanB phenotype-vanA genotype incongruent E. faecium in the Middle East region. Molecular typing indicates clonal spread and high occurrence of virulence genes, especially esp genes, associated with epidemic clones.


Subject(s)
Bacterial Proteins/genetics , Carbon-Oxygen Ligases/genetics , Enterococcus faecium/drug effects , Enterococcus faecium/isolation & purification , Vancomycin Resistance , Academic Medical Centers , Bacterial Proteins/metabolism , Carbon-Oxygen Ligases/metabolism , Cluster Analysis , DNA, Bacterial/genetics , Electrophoresis, Gel, Pulsed-Field , Enterococcus faecium/classification , Enterococcus faecium/genetics , Feces/microbiology , Genotype , Gram-Positive Bacterial Infections/microbiology , Humans , Molecular Typing , Phenotype , Saudi Arabia , Virulence Factors/genetics
6.
J Vasc Access ; 8(4): 287-95, 2007.
Article in English | MEDLINE | ID: mdl-18161676

ABSTRACT

PURPOSE: The creation of a vascular access is necessary in hemodialysis patients, including those with marginal vessels. Upper arm fistulae are attractive due to the ease of creation and of achieving high access flow rates. Cephalic arch stenosis (CAS) can lead to failure of upper arm fistulae and is increasingly identified. We hypothesized that CAS is promoted by high blood flow rates, brachiocephalic fistulae, and an angle of cephalic vein insertion approaching 90 degrees. METHODS: All patients requiring a fistulogram between January 2004 and May 2006 had surveillance fluoroscopy of the central veins. Demographic, clinical and laboratory parameters were collected and the angle of the cephalic vein insertion measured by 3 blinded independent observers. RESULTS: Fifty-eight patients had fistulograms and CAS was detected in 18 subjects. Significant differences between the CAS and non-CAS groups were brachiocephalic fistula site (p = 0.046), access flow (mL/min) (p = 0.012), and absence of diabetes (p = 0.03). Univariate predictors of CAS include access flow (per 100 mL/min) (p = 0.042), platelet count (p = 0.031) and calcium-phosphate product (p = 0.026). The relationship of brachiocephalic site and CAS was confounded by access flow [(per 100 mL/min)*brachiocephalic fistula site (p = 0.016)] and fistula age [brachiocephalic fistula site*fistula age (p = 0.017)]. In multivariate analysis, renovascular disease, calcium-phosphate product, platelet count and access flow (per 100 mL/min)*brachiocephalic fistula predicted CAS (p < 0.001, Negelkerke's R-Square = 0.55). The angle of insertion of the cephalic vein was not predictive for CAS. CONCLUSIONS: CAS may be a long-term consequence of high blood flow rates. The interaction of access flow and brachiocephalic fistula supports the hypothesis that high flow through a brachiocephalic fistula promotes CAS. The multiple factors influencing cephalic arch remodeling require further research.


Subject(s)
Arm/blood supply , Arteriovenous Shunt, Surgical/adverse effects , Brachial Artery/surgery , Brachiocephalic Veins/surgery , Graft Occlusion, Vascular/etiology , Kidney Failure, Chronic/therapy , Renal Dialysis , Adult , Aged , Blood Flow Velocity , Brachial Artery/physiopathology , Brachiocephalic Veins/diagnostic imaging , Brachiocephalic Veins/physiopathology , Calcium/blood , Calcium Phosphates/blood , Constriction, Pathologic , Female , Fluoroscopy , Graft Occlusion, Vascular/epidemiology , Graft Occlusion, Vascular/physiopathology , Humans , Kidney Failure, Chronic/diagnostic imaging , Kidney Failure, Chronic/physiopathology , Logistic Models , Male , Middle Aged , Platelet Count , Prevalence , Prospective Studies , Regional Blood Flow , Risk Assessment , Risk Factors , Time Factors , Treatment Failure
SELECTION OF CITATIONS
SEARCH DETAIL
...