Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Nanoscale Adv ; 6(4): 1259-1268, 2024 Feb 13.
Article in English | MEDLINE | ID: mdl-38356635

ABSTRACT

Combustion aerosol processes can uniquely embed noble metals into semiconducting particles. Here, monocrystalline SnO2 particles embedded with Pd and/or PdOx were made by flame spray pyrolysis (FSP) of appropriate precursors through microexplosions by droplet-to-particle conversion as the crystal size was proportional to the cube root of precursor solution concentration, C. These particles were air-annealed and leached with nitric acid for removal of metallic Pd from their surface. The SnO2 crystal size varied from 11 to 24 nm and was in close agreement with the primary particle size determined by nitrogen adsorption. The embedded fraction of Pd ranged from about 30 to 80% of the nominal Pd-content. This was achieved by judiciously varying the C, Pd content and the ratio of precursor solution to dispersion oxygen flowrates during FSP. The response of sensors made by doctor blading films of such particles to 1 ppm of acetone and CO was evaluated at 350 °C and 50% relative humidity. Embedding Pd/PdOx into SnO2 significantly increased the sensor response: 2-6 times over that of pure or conventionally-made Pd-containing SnO2 sensors at low nominal Pd-contents (0.2 mol%). For higher ones (i.e. 1 mol% Pd), the sensor response was enhanced by up to two orders of magnitude. This is attributed to Pd atoms in the SnO2 lattice near the particle surface and/or Pd/PdOx clusters acting as nanoelectrodes into SnO2 films and altering their transducing properties as shown by high resolution electron microscopy, XPS and baseline resistance measurements of pure and Pd-embedded SnO2 sensing films.

2.
Inhal Toxicol ; 30(4-5): 159-168, 2018.
Article in English | MEDLINE | ID: mdl-29932004

ABSTRACT

Direct physicochemical interactions between the major components of electronic cigarette liquids (e-liquids): glycerol (VG) and propylene glycol (PG), and lung surfactant (LS) were studied by determining the dynamic surface tension under a simulated breathing cycle using drop shape method. The studies were performed for a wide range of concentrations based on estimated doses of e-liquid aerosols (up to 2500 × the expected nominal concentrations) and for various VG/PG ratios. The results are discussed as relationships among mean surface tension, surface tension amplitude, and surface rheological properties (dilatational elasticity and viscosity) versus concentration and composition of e-liquid. The results showed that high local concentrations (>200 × higher than the estimated average dose after a single puffing session) may induce measurable changes in biophysical activity of LS; however, only ultra-high e-liquid concentrations inactivated the surfactant. Physiochemical characterization of e-liquids provide additional insights for the safety assessment of electronic nicotine delivery systems (ENDS).


Subject(s)
Biological Products/chemistry , Electronic Nicotine Delivery Systems , Glycerol/chemistry , Propylene Glycol/chemistry , Vaping , Aerosols , Computer Simulation , Elasticity , Glycerol/administration & dosage , Glycerol/adverse effects , Inhalation Exposure , Models, Chemical , Numerical Analysis, Computer-Assisted , Propylene Glycol/administration & dosage , Propylene Glycol/adverse effects , Risk Assessment , Surface Tension , Vaping/adverse effects , Viscosity
SELECTION OF CITATIONS
SEARCH DETAIL
...