1.
J Endourol ; 22(6): 1147-51, 2008 Jun.
Article in English | MEDLINE | ID: mdl-18578650

ABSTRACT

BACKGROUND AND PURPOSE: There have been several reports of rhabdomyolysis occurring after prolonged laparoscopic procedures in the flank position. Accordingly, we evaluated interface pressures between the skin and three commonly used operating room table surfaces. The aim of our study was to determine if pressure changes could be related to body mass index (BMI), sex, position, and/or the table surface material. PATIENTS AND METHODS: Ten men and 10 women were grouped according to BMI <25 or >or=25, with five participants in each group. Subjects were placed in the left lateral decubitus position with the operating table flat, half flexed, fully flexed, half flexed with the kidney rest elevated, and fully flexed with the kidney rest elevated. Interface pressures were recorded, using an X-Sensor pressure sensing mat, for 5-minute periods in each of the described positions on each surface. RESULTS: Sex and BMI were statistically significant predictors of increased pressures (P= 0.0042 and 0.0402, respectively). The parameter estimate for the difference between men and women was 4.63 mm Hg (P= 0.0002), and the difference for BMI >or= 25 compared with <25 was also significant (P < 0.0209). Full table flexion (50-degree) produced significantly higher pressures than both flat (P= 0.0001) and the half-flexed (25-degree) position (P < 0.0001). Positions with the kidney rest elevated were associated with significantly higher pressures than without elevation (P < 0.0001). With regard to the surface used, egg crate provided lower pressures than gel pads (P= 0.0117). CONCLUSION: Women have significantly lower interface pressures when compared with men. BMI >or= 25 also increases interface pressures. The use of the kidney rest is associated with markedly increased pressure; use of a half-flexed position is preferable to a full-flexed position. These data have implications for patient positioning and identification of persons at risk for rhabdomyolysis during laparoscopic renal surgery.


Subject(s)
Awards and Prizes , Laparoscopy/adverse effects , Posture/physiology , Rhabdomyolysis/etiology , Rhabdomyolysis/physiopathology , Sex Characteristics , Skin/physiopathology , Body Mass Index , Female , Humans , Kidney/physiopathology , Kidney/surgery , Male , Pressure , Risk Factors
2.
Urology ; 70(5): 883-7, 2007 Nov.
Article in English | MEDLINE | ID: mdl-17919698

ABSTRACT

OBJECTIVES: The processing of standard flexible cystoscopes is time-consuming and potentially hazardous to healthcare staff. We evaluated a novel flexible cystoscope system containing a disposable sheath, which obviates the need for chemical processing. METHODS: A total of 100 patients undergoing office cystoscopy were randomized into a "sheath" or a control group (n = 50 for each group). Disposable Slide-On sheaths and the CST-2000 Flexible Cystoscope System were used in the former group. A standard 16F flexible cystoscope, manually cleaned and disinfected with Cidex OPA or Rapicide, was used in the control group and the preparation times were recorded. Questionnaires to assess cystoscope setup, handling, optical quality, and patient comfort were completed by the physician, nursing staff, and patients. RESULTS: Data were available for 97 patients. The mean total time required for preparation of the cystoscopes was 10.7, 14.7, and 42.2 minutes for the sheath (n = 49), Rapicide (n = 21), and Cidex OPA (n = 27), respectively (P <0.01 for all comparisons). The control group scored better than the sheath group with regard to ease of cystoscope insertion (9.1 versus 7.7), cystoscope handling (8.8 versus 8.1), and irrigation setup (8.8 versus 8.2; all P < or = 0.01). No statistically significant difference was found between groups for procedure time, optical quality, or patient comfort, either during or after the procedure. CONCLUSIONS: The EndoSheath System can save 4 to 31 minutes of processing time while avoiding exposure to irritants found in conventional soaking methods. Although maneuvering of the sheathed cystoscope was slightly more difficult, the optical quality and patient comfort were similar to those of standard flexible cystoscopy.


Subject(s)
Cystoscopes , Cystoscopy/standards , Adult , Aged , Aged, 80 and over , Equipment Design , Female , Humans , Male , Middle Aged