Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Euro Surveill ; 22(18)2017 May 04.
Article in English | MEDLINE | ID: mdl-28494845

ABSTRACT

A new rapid assay for detecting oseltamivir resistance in influenza virus, iART, was used to test 149 clinical specimens. Results were obtained for 132, with iART indicating 41 as 'resistant'. For these, sequence analysis found known and suspected markers of oseltamivir resistance, while no such markers were detected for the remaining 91 samples. Viruses isolated from the 41 specimens showed reduced or highly reduced inhibition by neuraminidase inhibition assay. iART may facilitate broader antiviral resistance testing.


Subject(s)
Antiviral Agents/pharmacology , Drug Resistance, Viral , Influenza A Virus, H1N1 Subtype/drug effects , Neuraminidase/antagonists & inhibitors , Oseltamivir/pharmacology , Antiviral Agents/therapeutic use , Humans , Influenza A Virus, H1N1 Subtype/genetics , Influenza A Virus, H1N1 Subtype/isolation & purification , Influenza, Human , Microbial Sensitivity Tests/methods , Neuraminidase/genetics , Neuraminidase/metabolism , Neuraminidase/therapeutic use , Oseltamivir/therapeutic use
2.
Biosens Bioelectron ; 26(10): 4117-23, 2011 Jun 15.
Article in English | MEDLINE | ID: mdl-21549586

ABSTRACT

We report here the first pre-clinical demonstration of continuous glucose tracking by fluorophore-labeled and genetically engineered glucose/galactose binding protein (GGBP). Acrylodan-labeled GGBP was immobilized in a hydrogel matrix at the tip of a small diameter optical fiber contained in a stainless steel needle. The fiber optic biosensors were inserted subcutaneously into Yucatan and Yorkshire swine, and the sensor response to changing glucose levels was monitored at intervals over a 7-day period. Sensor mean percent error on day 7 was 16.4±5.0% using a single daily reference blood glucose value to calibrate the sensor. The GGBP sensor's susceptibility to common interferents was tested in a well-plate system using human sera. No significant interference was observed from the tested interferents except for tetracycline at the drug's maximum plasma concentration. The robust performance of the GGBP-based fiber optic sensor in swine models and resistance to interferents indicates the potential of this technology for continuous glucose monitoring in humans.


Subject(s)
Biosensing Techniques/methods , Blood Glucose/analysis , Escherichia coli Proteins , Monosaccharide Transport Proteins , Animals , Biosensing Techniques/instrumentation , Escherichia coli Proteins/chemistry , Humans , Immobilized Proteins/chemistry , Models, Animal , Monitoring, Physiologic/instrumentation , Monitoring, Physiologic/methods , Monosaccharide Transport Proteins/chemistry , Optical Fibers , Protein Conformation , Sus scrofa , Swine , Swine, Miniature
SELECTION OF CITATIONS
SEARCH DETAIL
...