Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
Front Reprod Health ; 5: 1118030, 2023.
Article in English | MEDLINE | ID: mdl-37383290

ABSTRACT

Introduction: Globally, many young women face the overlapping burden of HIV infection and unintended pregnancy. Protection against both may benefit from safe and effective multipurpose prevention technologies. Methods: Healthy women ages 18-34 years, not pregnant, seronegative for HIV and hepatitis B surface antigen, not using hormonal contraception, and at low risk for HIV were randomized 2:2:1 to continuous use of a tenofovir/levonorgestrel (TFV/LNG), TFV, or placebo intravaginal ring (IVR). In addition to assessing genital and systemic safety, we determined TFV concentrations in plasma and cervicovaginal fluid (CVF) and LNG levels in serum using tandem liquid chromatography-mass spectrometry. We further evaluated TFV pharmacodynamics (PD) through ex vivo CVF activity against both human immunodeficiency virus (HIV)-1 and herpes simplex virus (HSV)-2, and LNG PD using cervical mucus quality markers and serum progesterone for ovulation inhibition. Results: Among 312 women screened, 27 were randomized to use one of the following IVRs: TFV/LNG (n = 11); TFV-only (n = 11); or placebo (n = 5). Most screening failures were due to vaginal infections. The median days of IVR use was 68 [interquartile range (IQR), 36-90]. Adverse events (AEs) were distributed similarly among the three arms. There were two non-product related AEs graded >2. No visible genital lesions were observed. Steady state geometric mean amount (ssGMA) of vaginal TFV was comparable in the TFV/LNG and TFV IVR groups, 43,988 ng/swab (95% CI, 31,232, 61,954) and 30337 ng/swab (95% CI, 18,152, 50,702), respectively. Plasma TFV steady state geometric mean concentration (ssGMC) was <10 ng/ml for both TFV IVRs. In vitro, CVF anti-HIV-1 activity showed increased HIV inhibition over baseline following TFV-eluting IVR use, from a median of 7.1% to 84.4% in TFV/LNG, 15.0% to 89.5% in TFV-only, and -27.1% to -20.1% in placebo participants. Similarly, anti-HSV-2 activity in CVF increased >50 fold after use of TFV-containing IVRs. LNG serum ssGMC was 241 pg/ml (95% CI 185, 314) with rapid rise after TFV/LNG IVR insertion and decline 24-hours post-removal (586 pg/ml [95% CI 473, 726] and 87 pg/ml [95% CI 64, 119], respectively). Conclusion: TFV/LNG and TFV-only IVRs were safe and well tolerated among Kenyan women. Pharmacokinetics and markers of protection against HIV-1, HSV-2, and unintended pregnancy suggest the potential for clinical efficacy of the multipurpose TFV/LNG IVR. Clinical Trial Registration: NCT03762382 [https://clinicaltrials.gov/ct2/show/NCT03762382].

2.
J Acquir Immune Defic Syndr ; 89(1): 87-97, 2022 01 01.
Article in English | MEDLINE | ID: mdl-34878438

ABSTRACT

OBJECTIVE: To describe and compare systemic and local pharmacokinetics (PK) and cervicovaginal (CV) pharmacodynamics (PD) of oral tenofovir disoproxil fumarate (TDF) in combination with emtricitabine (FTC) with tenofovir (TFV) intravaginal ring (IVR). DESIGN: Phase I, randomized, parallel-group study. Women (n = 22) used TDF/FTC oral tablets daily or TFV IVR continuously and were assessed at baseline and 14 days. METHODS: TFV and FTC concentrations were measured in plasma, CV fluid (CVF), and CV tissue. TFV-diphosphate and FTC-triphosphate were assessed in CV tissue. In vitro PD antiviral activities of TFV and FTC (using in vivo concentration ranges) were modeled in the CVF and by infecting CV tissue explants ex vivo with HIV-1BaL. RESULTS: Adverse events (AEs) were more common with oral TDF/FTC use (P < 0.01). The median CVF TFV concentrations were 106 ng/mL after use of TFV IVR vs. 102 ng/mL for TDF/FTC. The median TFV and TFV-diphosphate concentrations in CV tissue were >100-fold higher among IVR users. The median CVF FTC concentrations were 103 ng/mL. FTC and FTC-triphosphate were detected in all CV tissues from TDF/FTC users. HIV inhibitory activity of CVF increased significantly with treatment in both cohorts (P < 0.01) but was higher in TFV IVR users (P < 0.01). In vitro inhibition of tissue infection with ex vivo administration of TFV and FTC was dose dependent, with maximal efficacy achieved with 10 µg/mL TFV, 1 µg/mL FTC, and 0.1 µg/mL of TFV and FTC combined. CONCLUSIONS: Both products were safe and increased mucosal HIV inhibitory activity. In addition to systemic protection, oral TDF/FTC displays a PK/PD profile compatible with CV mucosal antiviral activity. TFV IVR resulted in fewer AEs, lower TFV plasma concentrations, higher CVF and tissue TFV and TFV-DP concentrations, and greater anti-HIV activity in CVF.


Subject(s)
Anti-HIV Agents , HIV Infections , Administration, Intravaginal , Administration, Oral , Emtricitabine/pharmacology , Emtricitabine/therapeutic use , Female , Genitalia , HIV Infections/drug therapy , HIV Infections/prevention & control , Humans , Tenofovir
3.
Clin Transl Med ; 7(1): 37, 2018 Nov 07.
Article in English | MEDLINE | ID: mdl-30402770

ABSTRACT

BACKGROUND: Adherence is critical for successful topical, vaginally delivered anti-retroviral (ARV)-based HIV pre-exposure prophylaxis (PrEP). Quantitating systemic or tissue ARV levels through LC-MS/MS is currently viewed as the most reliable measure of adherence. However, for placebo-controlled trials, this is a high cost analysis that measures adherence only in the drug treatment group. A desirable marker of adherence is one that is measured in both placebo and drug treatment groups using a simple on-site clinical laboratory test, which allows necessary interventions for supporting participant adherence. Our objective was to develop adherence markers for four vaginal placebo products currently used as microbicide delivery systems: gel, film, insert, and intravaginal ring. Excipient and spectroscopy-based approaches were used for preclinical development of the placebo markers and subsequently validated by the CONRAD 135 study. The study collected vaginal swabs collected each day for 1 week post vaginal application of gel, film, or insert in the clinic with or without sex. Intravaginal rings were collected after 1 day, 7, and 30 days of use. RESULTS: Placebo gel, film, and insert in vaginal swabs were successfully detected by specific excipient colorimetric or probe-based assays for hydroxyethylcellulose, glycerin, and sorbitol respectively, as well as spectroscopy-based prediction models. The range of detection for gel, film, and insert in swabs collected up to 16 h post vaginal application was 70-100% of the total swabs per time point, with some markers showing potential for longer duration. Decreasing residual glycerin levels and increasing bioanalyte penetration of vaginally used intravaginal rings showed significant changes between 1 and 30 days of use. CONCLUSIONS: We demonstrated clinical proof-of-concept that adherence markers for placebo product can be measured using simple, lower cost approaches. Measuring adherence in both placebo and drug arms of a HIV PrEP study would better inform future trial designs.

4.
PLoS One ; 13(5): e0197906, 2018.
Article in English | MEDLINE | ID: mdl-29799875

ABSTRACT

BACKGROUND: The topical HIV prevention (microbicides) field is in acute need of a method to rapidly and objectively measure adherence to product use in clinical trials. Infrared (IR) spectroscopy has been used in many pharmaceutical and forensic applications but has yet to be applied to adherence monitoring. In this study, we report on efforts to test the feasibility of using IR spectroscopy as a means to measure residual active or placebo vaginal product, semen exposure and vaginal insertion from a single swab. METHODS: A portable IR spectrometer equipped with diamond attenuated total reflectance (ATR) was used to capture spectra of unused vs. vaginally-used swabs, vaginal swabs containing semen, and vaginal swabs to which either tenofovir-containing or matching placebo products (vaginal gel or insert) were added. Spectral data obtained from swabs placed directly on the spectrometer were divided into calibration and testing sets for developing and validating discriminant models set up to provide yes/no predictions of: vaginal vs. non-vaginal use, presence vs. no presence of each test product, and presence vs. no presence of semen. Further validation of models was performed using vaginal swabs collected from a clinical study evaluating vaginally administered placebo insert formulations. RESULTS: For each discriminant model developed to predict vaginal vs. non-vaginal use, presence vs. no presence of each test product, and presence vs. no presence of semen, classified validation samples not included in the model development were correctly identified into their respective classes with minimal prediction error. Clinically obtained vaginal swabs collected 15-60 minutes after placebo insert use were also correctly identified, further validating the models. CONCLUSION: Our findings demonstrate the proof of concept that IR spectroscopy can be a method for rapid detection and characterization of microbicide products and biological fluids present in vaginal swabs. This novel method has potential to support real-time, on-site adherence monitoring in clinical or field settings.


Subject(s)
Anti-Infective Agents/administration & dosage , Patient Compliance/statistics & numerical data , Spectroscopy, Fourier Transform Infrared , Administration, Intravaginal , Discriminant Analysis , Feasibility Studies , Female , Humans , Male , Multivariate Analysis , Placebos , Semen/metabolism , Time Factors
5.
PLoS One ; 9(12): e114368, 2014.
Article in English | MEDLINE | ID: mdl-25489736

ABSTRACT

BACKGROUND: Poor and inconsistent use of study products has hindered clinical HIV prevention studies. It is important to be able to monitor product adherence and protocol compliance in order to determine microbicide efficacy and safety more accurately. Current methods for monitoring adherence are subjective, non-specific, or invasive. Herein, we present a composite, objective measure of product adherence and protocol compliance to assess vaginal insertion, semen exposure and drug expulsion utilizing DNA, protein, and drug isolated directly from returned, vaginally used gel applicators. METHODS: DNA, vaginal cells, and residual tenofovir were isolated from vaginally inserted applicators. Vaginal and semen biomarkers were amplified using a multiplex PCR to determine vaginal insertion. Vaginal cells were fixed followed by cytokeratin 4 immunocytochemistry to confirm DNA assessment of vaginal insertion. Tenofovir was extracted and quantitated through LC-MS/MS. RESULTS: DNA isolated from vaginally inserted applicators were positive for vaginal bacteria DNA and the control eukaryotic gene, amelogenin, while manually handled, "sham", applicators were negative for both. Semen exposure was independently determined by simultaneous amplification of one or both Y-chromosomal genes, SRY and TSPY4. Vaginal insertion determination by DNA analysis was further confirmed by positive cytokeratin 4 (CK4) immunocytochemistry of vaginal cells remaining on the gel applicators. On the contrary, sham applicators provided very few cells when swabbed, and they were all negative for CK4. CK4 was not found in epidermal cells from the hand. Drug expulsion was detected through quantitation of residual gel present on the surface of returned applicators. Sham applicators had no detectable tenofovir. CONCLUSION: Utilizing a composite, triple marker based panel of DNA, protein, and drug present on the surface of returned vaginal gel applicators, it is possible to determine, objectively and non-invasively, product adherence, protocol compliance, and semen exposure in microbicide trials.


Subject(s)
DNA/metabolism , Guideline Adherence/statistics & numerical data , HIV Infections/prevention & control , Keratin-4/metabolism , Outcome Assessment, Health Care/methods , Patient Compliance/statistics & numerical data , Semen/virology , Adenine/administration & dosage , Adenine/analogs & derivatives , Adenine/pharmacology , Administration, Topical , Adult , Anti-HIV Agents/administration & dosage , Anti-HIV Agents/pharmacology , Biomarkers/metabolism , Cellulose/administration & dosage , Cellulose/analogs & derivatives , Cellulose/pharmacology , DNA/genetics , Environmental Exposure/analysis , Feasibility Studies , Female , HIV Infections/genetics , HIV Infections/metabolism , HIV Infections/transmission , Humans , Male , Middle Aged , Organophosphonates/administration & dosage , Organophosphonates/pharmacology , Tenofovir , Vagina/drug effects , Vagina/virology , Young Adult
6.
Biol Reprod ; 91(2): 34, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24920038

ABSTRACT

An intrafollicular increase in proteolytic activity drives ovulatory events. Surprisingly, the periovulatory expression profile of the membrane-type matrix metalloproteinases (MT-MMPs), unique proteases anchored to the cell surface, has not been extensively examined. Expression profiles of the MT-MMPs were investigated in ovarian tissue from well-characterized rat and macaque periovulatory models and naturally cycling women across the periovulatory period. Among the six known MT-MMPs, mRNA expression of Mmp14, Mmp16, and Mmp25 was increased after human chorionic gonadotropin (hCG) administration in rats. In human granulosa cells, mRNA expression of MMP14 and MMP16 increased following hCG treatment. In contrast, mRNA levels of MMP16 and MMP25 in human theca cells were unchanged before ovulation but declined by the postovulatory stage. In macaque granulosa cells, hCG increased mRNA for MMP16 but not MMP14. Immunoblotting showed that protein levels of MMP14 and MMP16 in rats increased, similar to their mRNA expression. In macaque granulosa cells, only the active form of the MMP14 protein increased after hCG, unlike its mRNA or the proprotein. By immunohistochemistry, both MMP14 and MMP16 localized to the different ovarian cell types in rats and humans. Treatment with hCG resulted in intense immunoreactivity of MMP14 and MMP16 proteins in the granulosa and theca cells. The present study shows that MMP14 and MMP16 are increased by hCG administration in the ovulating follicle, demonstrating that these MMPs are conserved among rats, macaques, and humans. These findings suggest that MT-MMPs could have an important role in promoting ovulation and remodeling of the ovulated follicle into the corpus luteum.


Subject(s)
Gene Expression Regulation, Enzymologic/physiology , Macaca fascicularis/physiology , Matrix Metalloproteinase 14/metabolism , Matrix Metalloproteinase 16/metabolism , Ovary/enzymology , Ovulation/physiology , Animals , Female , GPI-Linked Proteins/genetics , GPI-Linked Proteins/metabolism , Humans , Matrix Metalloproteinase 14/genetics , Matrix Metalloproteinase 16/genetics , Matrix Metalloproteinases, Membrane-Associated/genetics , Matrix Metalloproteinases, Membrane-Associated/metabolism , RNA, Messenger/genetics , RNA, Messenger/metabolism , Rats , Rats, Sprague-Dawley , Species Specificity , Transcriptome
7.
Sex Transm Dis ; 41(12): 739-46, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25581811

ABSTRACT

BACKGROUND: Objective biomarkers of product use and protocol compliance are urgently needed. We compared the sensitivity and specificity of DNA and protein-based biomarkers, obtained from used vaginal gel applicators, to visual inspection of those applicators under ambient light (visual inspection of returned applicator [VIRA]) and ultraviolet light (UVL). METHODS: Forty women inserted hydroxyethylcellulose placebo gel vaginal applicators under direct observation. Applicators were evaluated by VIRA, UVL, and DNA/protein-based methods at 2 time points: within 7 days of the visit and after storing applicators for approximately 30 days. Semen biomarkers were assayed from vaginal swabs and returned applicators. RESULTS: The overall sensitivity and specificity of DNA and protein-based biomarkers in determining vaginal insertion versus sham handling of returned applicators were 98.3% and 100%, respectively, at both 7- and 30-day evaluations. The overall sensitivity and specificity of VIRA at 7 and 30 days after collection were significantly lower than those of DNA and protein-based biomarkers. Ultraviolet light inspection also had significantly lower overall sensitivity and overall specificity compared with DNA and protein biomarkers. The sensitivity of DNA and protein-based biomarkers for detecting insertion of wiped applicators was 95%, whereas the sensitivity of VIRA (range of 24%-28%) and UVL inspection (range, 38%-84%) was low for this subset. It was feasible to obtain semen biomarkers from vaginal swabs and returned used applicators. CONCLUSIONS: DNA and protein-based biomarkers offer significantly higher sensitivity and specificity compared with VIRA and UVL assessment. The accuracy of these objective biomarkers is maintained despite storage of returned products for approximately 30 days and under conditions potentially modeling field use.


Subject(s)
Anti-Infective Agents/administration & dosage , Drug Delivery Systems/instrumentation , HIV Infections/prevention & control , Patient Compliance/statistics & numerical data , Vaginal Creams, Foams, and Jellies/administration & dosage , Administration, Intravaginal , Biomarkers/chemistry , DNA , Drug Delivery Systems/statistics & numerical data , Female , Humans , Semen , Sensitivity and Specificity , Ultraviolet Rays
8.
Contraception ; 88(3): 387-95, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23312930

ABSTRACT

BACKGROUND: Developing an objective, reliable method to determine semen exposure in cervicovaginal fluids is important for accurately studying the efficacy of vaginal microbicides and contraceptives. Y-chromosome biomarkers offer better stability, sensitivity, and specificity than protein biomarkers. TSPY4 belongs to the TSPY (testis-specific protein Y-encoded) family of homologous genes on the Y-chromosome. Using a multiplex PCR amplifying TSPY4, amelogenin, and Sex-determining region in the Y chromosome (SRY), our objective was to determine whether a gene in the TSPY family was a more sensitive marker of semen exposure in cervicovaginal fluids than SRY. STUDY DESIGN: The multiplex polymerase chain reaction (PCR) was developed using sperm and vaginal epithelial (female) DNA. Diluted sperm DNA and mixed male/female DNA was used to determine the sensitivity of the multiplex PCR. Potential interference of TSPY4 amplification by components in cervicovaginal and seminal fluids was determined. TSPY4 and SRY amplification was also investigated in women participating in a separate IRB-approved clinical study in which cervicovaginal swab DNA was collected before semen exposure and at various time points after exposure. RESULTS: TSPY4, SRY, and amelogenin were amplified in sperm DNA, but only amelogenin in female DNA. The limit of sperm DNA from which TSPY4 could be amplified was lower than SRY (4 pg vs 80 pg). TSPY4 could also be amplified from mixed male/female DNA. Amplification was not affected by cervicovaginal and seminal components. Using cervicovaginal swab DNA from three women before and after semen exposure, TSPY4 was detected up to 72 h post exposure while SRY detection was observed up to 24-48 h. TSPY4 was detected up to 7 days post exposure in one out of three women. CONCLUSIONS: We have demonstrated that TSPY4 is a new sensitive, and sperm-specific biomarker. The multiplex PCR incorporating this new biomarker has potential to be an objective measure for determining semen exposure in clinical trials of vaginal products such as contraceptives and HIV pre/post-exposure prophylaxis agents.


Subject(s)
Biomarkers/analysis , Body Fluids/chemistry , Cell Cycle Proteins/analysis , HIV Infections/prevention & control , Semen/chemistry , Vagina/chemistry , Amelogenin/analysis , Amelogenin/genetics , Cell Cycle Proteins/genetics , Contraception , DNA/analysis , Female , Humans , Male , Polymerase Chain Reaction , Sensitivity and Specificity , Sex-Determining Region Y Protein/analysis , Sex-Determining Region Y Protein/genetics , Spermatozoa/chemistry
9.
J Am Soc Nephrol ; 11(8): 1419-1425, 2000 Aug.
Article in English | MEDLINE | ID: mdl-10906155

ABSTRACT

Mice transgenic for bovine growth hormone (GH) develop progressive glomerulosclerosis. However, the proximal signaling events that lead to increased matrix deposition in this pathologic condition are still unclear. Components of the L-arginine metabolic pathway, especially inducible nitric oxide (NO) synthase (iNOS), ornithine aminotransferase (OAT), and ornithine decarboxylase (ODC), have been associated with glomerular scarring. In this study, mesangial cells were treated with GH, and the expression of iNOS, ODC, and OAT was determined using reverse transcription-PCR. In addition, nitrite accumulation in the conditioned media of mesangial cell cultures was measured in the presence or absence of GH. The findings revealed that GH increased iNOS transcript levels in a dose-dependent manner, with the highest levels being attained at GH concentrations of 20 to 50 ng/ml. The GH-induced increase in iNOS transcript levels was accompanied by a significant increase in nitrite concentrations in conditioned media, which was blocked by the addition of L-N(G)-monomethylarginine. The effect of GH (50 ng/ml) in eliciting nitrite production was as potent as that of bacterial lipopolysaccharide (10 microg/ml). The expression of OAT and ODC, in contrast, was not altered at any of the GH concentrations tested. GH receptor mRNA was also expressed by mesangial cells, independently of the GH concentration present in the cell culture medium. These data indicate that GH may interact with its receptor to regulate the L-arginine/NO pathway in mesangial cells, by directly modulating iNOS expression and NO production, without altering the arginase/OAT/ODC pathway.


Subject(s)
Glomerular Mesangium/enzymology , Growth Hormone/pharmacology , Nitric Oxide Synthase/metabolism , Animals , Cells, Cultured , Culture Media, Conditioned/chemistry , Dose-Response Relationship, Drug , Glomerular Mesangium/cytology , Glomerular Mesangium/drug effects , Lipopolysaccharides/pharmacology , Mice , Nitric Oxide Synthase/genetics , Nitric Oxide Synthase Type II , Nitrites/analysis , Ornithine Decarboxylase/metabolism , Ornithine-Oxo-Acid Transaminase/metabolism , RNA, Messenger/metabolism , omega-N-Methylarginine/pharmacology
SELECTION OF CITATIONS
SEARCH DETAIL
...