Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 126
Filter
1.
Heliyon ; 10(9): e30265, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38726196

ABSTRACT

Antimicrobial residues in animal-derived foods have become a major source of concern around the world. Oxytetracycline (OTC), one of these antibiotics that belongs to the tetracycline family should be detected in these matrices. Nanostructured metal oxides have attracted a lot of scientific attention due to their special characteristics that can be exploited for creating innovative nanodevices. Therefore, in the present study, we report the fabrication of cobalt-doped ZnO/GO nanocomposites for OTC sensors using a simple and environmentally friendly method that does not require toxic solvents. Contact angle measurements, X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS) and UV-Vis were used to confirm the successful fabrication of the Co-ZnO/GO nanocomposite and to determine the surface area, Structural, morphological features, chemical composition and purity of the nanocomposite. The electrochemical and electrocatalytic properties were recorded using cyclic voltammetry (CV), electrochemical impedance spectroscopy, and differential pulse voltammetry (DPV). Optimizing parameters such as scan rate, pH value, deposition time, and deposition potential, we achieve a wide linear concentration range from 10-12 M to 10-7 M, with an impressive detection limit of 1.6 10-13 M.Notably, our sensor exhibits remarkable selectivity, demonstrating its usefulness for the detection of oxytetracycline traces in real milk samples. These results emphasize the novelty and practical significance of our work and provide a promising avenue for the development of sensitive and selective electrochemical sensing platforms in various fields.

2.
Colloids Surf B Biointerfaces ; 239: 113902, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38599037

ABSTRACT

CD146, also known as melanoma cell adhesion molecule (MCAM), is overexpressed in various cancer patients, making it a valuable predictor for early diagnosis. In this work, an immune sandwich electrochemical biosensor is proposed for sensitive and non-invasive quantitative detection of CD146 in serum. Zirconium-based MOF (UIO-66) was modified by simultaneous copper atom doping, in situ growth carbon-based support and physical embedding of platinum nanoparticles (PtNPs). Triple-modified Cu-UIO-66@SWCNT/PtNPs nanocomposites with high stability and excellent electrochemical properties, serve as surface modification materials for glassy carbon electrodes. Anti-CD146 antibody (Ab1) was grafted onto the electrode surface via Pt-S bond. Meanwhile, the secondary antibody (Ab2) was conjugated with silver nanoparticles (AgNPs) to cooperate for CD146 capture and achieve secondary electrical signal amplification. Under optimal conditions, square wave voltammetry was employed to determine CD146 in the concentration range of 10-9-10-4 mg/mL and a limit of detection of 12 fg/mL was obtained. Finally, it was successfully applied to the analysis of CD146 in lung and liver cancer patients' serum samples.


Subject(s)
Biosensing Techniques , CD146 Antigen , Electrochemical Techniques , Zirconium , CD146 Antigen/blood , Humans , Zirconium/chemistry , Biosensing Techniques/methods , Electrochemical Techniques/methods , Metal Nanoparticles/chemistry , Electrodes , Silver/chemistry , Platinum/chemistry , Lung Neoplasms/blood , Lung Neoplasms/diagnosis , Limit of Detection , Nanotubes, Carbon/chemistry , Liver Neoplasms/blood , Liver Neoplasms/diagnosis
3.
Micromachines (Basel) ; 15(3)2024 Feb 21.
Article in English | MEDLINE | ID: mdl-38542544

ABSTRACT

We propose a new strategy using a sandwich approach for the detection of two HF biomarkers: tumor necrosis factor-α (TNF-α) and interleukin-10 (IL-10). For this purpose, magnetic nanoparticles (MNPs) (MNPs@aminodextran) were biofunctionalized with monoclonal antibodies (mAbs) using bis (sulfosuccinimidyl) suberate (BS3) as a cross-linker for the pre-concentration of two biomarkers (TNF-α and IL-10). In addition, our ISFETs were biofunctionalized with polyclonal antibodies (pAbs) (TNF-α and IL-10). The biorecognition between pAbs immobilized on the ISFET and the pre-concentrate antigen (Ag) on MNPs was monitored using electrochemical impedance spectroscopy (EIS). Our developed ImmunoFET showed a low detection limit (0.03 pg/mL) toward our target analyte when compared to previously published electrochemical immunosensors. It showed a higher sensitivity than for other HF biomarkers. Finally, the standard addition method was used to determine the unknown concentration in artificial saliva. The results matched with the expected values well.

4.
ACS Sens ; 8(10): 3623-3642, 2023 10 27.
Article in English | MEDLINE | ID: mdl-37819690

ABSTRACT

Over the past few decades, pathogens have posed a threat to human security, and rapid identification of pathogens should be one of the ideal methods to prevent major public health security outbreaks. Therefore, there is an urgent need for highly sensitive and specific approaches to identify and quantify pathogens. Clustered Regularly Interspaced Short Palindromic Repeats CRISPR/Cas systems and Argonaute (Ago) belong to the Microbial Defense Systems (MDS). The guided, programmable, and targeted activation of nucleases by both of them is leading the way to a new generation of pathogens detection. We compare these two nucleases in terms of similarities and differences. In addition, we discuss future challenges and prospects for the development of the CRISPR/Cas systems and Argonaute (Ago) biosensors, especially electrochemical biosensors. This review is expected to afford researchers entering this multidisciplinary field useful guidance and to provide inspiration for the development of more innovative electrochemical biosensors for pathogens detection.


Subject(s)
Biosensing Techniques , CRISPR-Cas Systems , Humans
5.
Nanomaterials (Basel) ; 13(16)2023 Aug 12.
Article in English | MEDLINE | ID: mdl-37630900

ABSTRACT

In this paper, a microconductometric sensor has been designed, based on a chitosan composite including alcohol dehydrogenase-and its cofactor-and gold nanoparticles, and was calibrated by differential measurements in the headspace of aqueous solutions of ethanol. The role of gold nanoparticles (GNPs) was crucial in improving the analytical performance of the ethanol sensor in terms of response time, sensitivity, selectivity, and reproducibility. The response time was reduced to 10 s, compared to 21 s without GNPs. The sensitivity was 416 µS/cm (v/v%)-1 which is 11.3 times higher than without GNPs. The selectivity factor versus methanol was 8.3, three times higher than without GNPs. The relative standard deviation (RSD) obtained with the same sensor was 2%, whereas it was found to be 12% without GNPs. When the air from the operator's mouth was analyzed just after rinsing with an antiseptic mouthwash, the ethanol content was very high (3.5 v/v%). The background level was reached only after rinsing with water.

6.
Talanta ; 265: 124784, 2023 Dec 01.
Article in English | MEDLINE | ID: mdl-37356191

ABSTRACT

We aim to develop an electrochemical sensor for a divalent metal ion (lead II), a highly toxic water contaminant. We explore a sensor formed with a hemicellulose polysaccharide extracted from the Opuntia Ficus Indica cactus associated with agarose as a sensitive layer deposited on a gold electrode. This sensor combines the functional groups of hemicellulose that could form a complex with metal ions and agarose with gelling properties to form a stable membrane. The sensor demonstrated a loading ability of Pb2+, with higher affinity compared to other metal ions such as Hg2+, Ni2+, and Cu2+, thanks to the chemical structure of hemicellulose. The detection was measured by square wave voltammetry based on a well-defined redox peak of the metal ions. The sensor shows high sensitivity towards Pb2+ with a detection limit of 1.3 fM. The application in river and sea water using the standard addition method for lead detection was studied.

7.
Talanta ; 260: 124630, 2023 Aug 01.
Article in English | MEDLINE | ID: mdl-37178675

ABSTRACT

Methanol (MeOH) is a solvent and cleaning agent used in industry, but it is poisonous when ingested. The recommended release threshold for MeOH vapor is 200 ppm. We present a novel sensitive micro-conductometric MeOH biosensor created by grafting alcohol oxidase (AOX) onto electrospun polystyrene-poly(amidoamine) dendritic polymer blend nanofibers (PS-PAMAM-ESNFs) on interdigitated electrodes (IDEs). The analytical performance of the MeOH microsensor was evaluated using gaseous MeOH, ethanol, and acetone samples collected from the headspace above aqueous solution with known concentration. The sensor's response time (tRes) fluctuates from 13 s to 35 s from lower to higher concentrations. The conductometric sensor has a sensitivity of 150.53 µS.cm-1 (v/v) for MeOH and a detection limit of 100 ppm in the gas phase. The MeOH sensor is 7.3 times less sensitive to ethanol and 136.8 times less sensitive to acetone. The sensor was verified for detecting MeOH in commercial rubbing alcohol samples.

8.
Nanomaterials (Basel) ; 13(10)2023 May 21.
Article in English | MEDLINE | ID: mdl-37242104

ABSTRACT

Microemulsions are novel drug delivery systems that have garnered significant attention in the pharmaceutical research field. These systems possess several desirable characteristics, such as transparency and thermodynamic stability, which make them suitable for delivering both hydrophilic and hydrophobic drugs. In this comprehensive review, we aim to explore different aspects related to the formulation, characterization, and applications of microemulsions, with a particular emphasis on their potential for cutaneous drug delivery. Microemulsions have shown great promise in overcoming bioavailability concerns and enabling sustained drug delivery. Thus, it is crucial to have a thorough understanding of their formulation and characterization in order to optimize their effectiveness and safety. This review will delve into the different types of microemulsions, their composition, and the factors that affect their stability. Furthermore, the potential of microemulsions as drug delivery systems for skin applications will be discussed. Overall, this review will provide valuable insights into the advantages of microemulsions as drug delivery systems and their potential for improving cutaneous drug delivery.

9.
Sensors (Basel) ; 23(7)2023 Apr 03.
Article in English | MEDLINE | ID: mdl-37050763

ABSTRACT

Biosensors are devices composed of a biorecognition part and of a transduction part [...].


Subject(s)
Biosensing Techniques
10.
Talanta ; 260: 124552, 2023 Aug 01.
Article in English | MEDLINE | ID: mdl-37087947

ABSTRACT

Previous researches have suggested the potential correlation between the development of breast cancer and the concentration of miRNA-21 in serum. Theoretically the doping of multivalent metal ions in WS2 could bring higher electron transfer capacity, but this hasn't been proven. To fill this research gap, through one-pot method we prepared seven nanocomposite structures modified with different metal ions (Co2+, Ni2+, Mn2+, Zn2+, Fe3+, Cr3+, La3+). Characterization revealed that ammonia produced by hydrothermal urea exfoliated the multilayer graphene oxide (MGO) and provided a nitrogen source for doping reduction to form a 3D flower-like structure (NrGOF) with high specific surface area. Meanwhile, the modification of WS2 by Fe3+ not only enhanced its electrochemical conductivity but also gave the material an additional peroxidase activity centre. In the composite Fe3+-WS2/NrGOF-AgNPs, NrGOF is used as a conductive loading interface for WS2, while Fe3+ served as the catalytic and electron transfer centre for secondary amplification of the electrochemical signal. The experimental results showed that the sensing platform has a low limit of detection (LOD) of 1.18 aM for miRNA-21 in the concentration range of 10-17-10-12 M and has been successfully applied to the detection of real serum samples.


Subject(s)
Biosensing Techniques , MicroRNAs , Nanocomposites , Trace Elements , Nanocomposites/chemistry , Electrochemical Techniques/methods , Biosensing Techniques/methods , Limit of Detection
SELECTION OF CITATIONS
SEARCH DETAIL