Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Digit Imaging ; 35(6): 1738-1747, 2022 12.
Article in English | MEDLINE | ID: mdl-35879495

ABSTRACT

Hepatic steatosis is a common condition and an early manifestation of a systemic metabolic syndrome. As of today, there is no broadly accepted method for the diagnosis of hepatic steatosis in contrast-enhanced CT images. This retrospective study evaluates the potential of quantitative iodine values in portal venous phase iodine images in dual-energy CT (DECT) by measuring iodine concentrations in regions of interest (ROI) and analyzing the absolute iodine concentration of the liver parenchyma as well as three different blood-normalized iodine concentrations in a study cohort of 251 patients. An independent two sample t-test (p < 0.05) was used to compare the iodine concentrations of healthy and fatty liver. Diagnostic performance was assessed by ROC (receiver operating characteristic) curve analysis. The results showed significant differences between the average iodine concentration of healthy and fatty liver parenchyma for the absolute and for the blood-normalized iodine concentrations. The study concludes that the iodine uptake of the liver parenchyma is impaired by hepatic steatosis, and that the measurement of iodine concentration can provide a suitable method for the detection of hepatic steatosis in quantitative iodine images. Suitable thresholds of quantitative iodine concentration values for the diagnosis of hepatic steatosis are provided.


Subject(s)
Fatty Liver , Iodine , Humans , Contrast Media , Retrospective Studies , Tomography, X-Ray Computed/methods , Fatty Liver/diagnostic imaging
2.
PLoS One ; 17(7): e0270805, 2022.
Article in English | MEDLINE | ID: mdl-35834594

ABSTRACT

Dual energy computed tomography (DECT) allows the quantification of specific materials such as iodine contrast agent in human body tissue, potentially providing additional diagnostic data. Yet full diagnostic value can only be achieved if physiological normal values for iodine concentrations are known. We retrospectively evaluated abdominal DECT scans of 105 patients with healthy liver between March and August 2018 (age 17 to 86 years, 43 female and 62 male). The iodine concentrations within ROIs of the liver parenchyma as well as of the abdominal aorta and main portal vein were obtained. We evaluated the absolute iodine concentration and blood-normalized iodine concentrations relating the measured iodine concentration of the liver parenchyma to those of the supplying vessels. The influence of age and gender on the iodine uptake was assessed. The absolute iodine concentration was significantly different for the male and female cohort, but the difference was eliminated by the blood-normalized values. The average blood-normalized iodine concentrations were 2.107 mg/ml (+/- 0.322 mg/ml), 2.125 mg/ml (+/- 0.426 mg/ml) and 2.103 mg/ml (+/- 0.317 mg/ml) for the portal vein normalized, aorta normalized and mixed blood normalized iodine concentrations, respectively. A significant negative correlation between the patients' age and the iodine concentration was detected only for the blood-normalized values. A physiological range for iodine concentration in portal venous phase contrast enhanced DECT images can be defined for absolute and blood-normalized values. Deviations of blood-normalized iodine concentration values might be a robust biomarker for diagnostic evaluation. Patient age but not the gender influences the blood-normalized iodine concentrations in healthy liver parenchyma.


Subject(s)
Iodine , Radiography, Dual-Energy Scanned Projection , Adolescent , Adult , Aged , Aged, 80 and over , Benchmarking , Contrast Media , Female , Humans , Iodides , Liver/diagnostic imaging , Male , Middle Aged , Radiography, Dual-Energy Scanned Projection/methods , Retrospective Studies , Tomography, X-Ray Computed/methods , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...