Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 111
Filter
1.
Sci Rep ; 14(1): 8974, 2024 04 18.
Article in English | MEDLINE | ID: mdl-38637577

ABSTRACT

Fully CMR-guided electrophysiological interventions (EP-CMR) have recently been introduced but data on the optimal CMR imaging protocol are scarce. This study determined the clinical utility of 3D non-selective whole heart steady-state free precession imaging using compressed SENSE (nsWHcs) for automatic segmentation of cardiac cavities as the basis for targeted catheter navigation during EP-CMR cavo-tricuspid isthmus ablation. Fourty-two consecutive patients with isthmus-dependent right atrial flutter underwent EP-CMR radiofrequency ablations. nsWHcs succeeded in all patients (nominal scan duration, 98 ± 10 s); automatic segmentation/generation of surface meshes of right-sided cavities exhibited short computation times (16 ± 3 s) with correct delineation of right atrium, right ventricle, tricuspid annulus and coronary sinus ostium in 100%, 100%, 100% and 95%, respectively. Point-by-point ablation adhered to the predefined isthmus line in 62% of patients (26/42); activation mapping confirmed complete bidirectional isthmus block (conduction time difference, 136 ± 28 ms). nsWHcs ensured automatic and reliable 3D segmentation of targeted endoluminal cavities, multiplanar reformatting and image fusion (e.g. activation time measurements) and represented the basis for precise real-time active catheter navigation during EP-CMR ablations of isthmus-dependent right atrial flutter. Hence, nsWHcs can be considered a key component in order to advance EP-CMR towards the ultimate goal of targeted substrate-based ablation procedures.


Subject(s)
Atrial Flutter , Catheter Ablation , Humans , Atrial Flutter/diagnostic imaging , Atrial Flutter/surgery , Surgical Mesh , Catheter Ablation/methods , Heart Atria/diagnostic imaging , Heart Atria/surgery , Arrhythmias, Cardiac , Treatment Outcome
2.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38646922

ABSTRACT

AIMS: High-power-short-duration (HPSD) ablation is an effective treatment for atrial fibrillation but poses risks of thermal injuries to the oesophagus and vagus nerve. This study aims to investigate incidence and predictors of thermal injuries, employing machine learning. METHODS AND RESULTS: A prospective observational study was conducted at Leipzig Heart Centre, Germany, excluding patients with multiple prior ablations. All patients received Ablation Index-guided HPSD ablation and subsequent oesophagogastroduodenoscopy. A machine learning algorithm categorized ablation points by atrial location and analysed ablation data, including Ablation Index, focusing on the posterior wall. The study is registered in clinicaltrials.gov (NCT05709756). Between February 2021 and August 2023, 238 patients were enrolled, of whom 18 (7.6%; nine oesophagus, eight vagus nerve, one both) developed thermal injuries, including eight oesophageal erythemata, two ulcers, and no fistula. Higher mean force (15.8 ± 3.9 g vs. 13.6 ± 3.9 g, P = 0.022), ablation point quantity (61.50 ± 20.45 vs. 48.16 ± 19.60, P = 0.007), and total and maximum Ablation Index (24 114 ± 8765 vs. 18 894 ± 7863, P = 0.008; 499 ± 95 vs. 473 ± 44, P = 0.04, respectively) at the posterior wall, but not oesophagus location, correlated significantly with thermal injury occurrence. Patients with thermal injuries had significantly lower distances between left atrium and oesophagus (3.0 ± 1.5 mm vs. 4.4 ± 2.1 mm, P = 0.012) and smaller atrial surface areas (24.9 ± 6.5 cm2 vs. 29.5 ± 7.5 cm2, P = 0.032). CONCLUSION: The low thermal lesion's rate (7.6%) during Ablation Index-guided HPSD ablation for atrial fibrillation is noteworthy. Machine learning based ablation data analysis identified several potential predictors of thermal injuries. The correlation between machine learning output and injury development suggests the potential for a clinical tool to enhance procedural safety.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Esophagus , Vagus Nerve Injuries , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/epidemiology , Male , Female , Esophagus/injuries , Esophagus/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Prospective Studies , Middle Aged , Vagus Nerve Injuries/etiology , Vagus Nerve Injuries/epidemiology , Incidence , Aged , Machine Learning , Risk Factors , Germany/epidemiology , Burns/epidemiology , Burns/etiology , Time Factors , Treatment Outcome , Pulmonary Veins/surgery , Vagus Nerve
4.
Int J Cardiovasc Imaging ; 40(2): 213-224, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37891450

ABSTRACT

PURPOSE: Mitral valve prolapse (MVP) is associated with left ventricle (LV) fibrosis, including the papillary muscles (PM), which is in turn linked to malignant arrhythmias. This study aims to evaluate comprehensive tissue characterization of the PM by cardiovascular magnetic resonance (CMR) imaging and its association with LV fibrosis observed by intraoperative biopsies. METHODS: MVP patients with indication for surgery due to severe mitral regurgitation (n = 19) underwent a preoperative CMR with characterization of the PM: dark-appearance on cine, T1 mapping, conventional bright blood (BB) and dark blood (DB) late gadolinium enhancement (LGE). CMR T1 mapping was performed on 21 healthy volunteers as controls. LV inferobasal myocardial biopsies were obtained in MVP patients and compared to CMR findings. RESULTS: MVP patients (54 ± 10 years old, 14 male) had a dark-appearance of the PM with higher native T1 and extracellular volume (ECV) values compared with healthy volunteers (1096 ± 78ms vs. 994 ± 54ms and 33.9 ± 5.6% vs. 25.9 ± 3.1%, respectively, p < 0.001). Seventeen MVP patients (89.5%) had fibrosis by biopsy. BB-LGE + in LV and PM was identified in 5 (26.3%) patients, while DB-LGE + was observed in LV in 9 (47.4%) and in PM in 15 (78.9%) patients. DB-LGE + in PM was the only technique that showed no difference with detection of LV fibrosis by biopsy. Posteromedial PM was more frequently affected than the anterolateral (73.7% vs. 36.8%, p = 0.039) and correlated with biopsy-proven LV fibrosis (Rho 0.529, p = 0.029). CONCLUSIONS: CMR imaging in MVP patients referred for surgery shows a dark-appearance of the PM with higher T1 and ECV values compared with healthy volunteers. The presence of a positive DB-LGE at the posteromedial PM by CMR may serve as a better predictor of biopsy-proven LV inferobasal fibrosis than conventional CMR techniques.


Subject(s)
Mitral Valve Prolapse , Humans , Male , Adult , Middle Aged , Mitral Valve Prolapse/diagnostic imaging , Mitral Valve Prolapse/surgery , Papillary Muscles/pathology , Heart Ventricles , Contrast Media , Predictive Value of Tests , Gadolinium , Fibrosis , Magnetic Resonance Imaging, Cine
5.
Europace ; 25(11)2023 11 02.
Article in English | MEDLINE | ID: mdl-37960936

ABSTRACT

AIMS: Low-voltage areas (LVAs) found during left atrial (LA) electroanatomical mapping are increasingly targeted by radiofrequency catheter ablation (RFCA) on top of pulmonary vein isolation to improve arrhythmia-free survival in patients with atrial fibrillation (AF). However, pre-procedural prediction of LVAs remains challenging. The purpose of the present study was to describe the association between parameters of LA function and dimensions, respectively, derived from pre-procedural cardiovascular magnetic resonance (CMR) imaging, and the presence of LVAs on LA voltage mapping. METHODS AND RESULTS: Patients who underwent first-time RFCA for paroxysmal or persistent AF and who were in stable sinus rhythm during pre-procedural CMR imaging were included in this study. Cardiovascular magnetic resonance-derived parameters of LA function and dimensions were calculated. Low-voltage areas were defined as areas with bipolar voltage amplitudes of ≤0.5 mV on electroanatomical mapping. In total, 259 consecutive patients were included in this analysis. Low-voltage areas were found in 25 of 259 patients (9.7%). Compared with those without LVAs, patients with LVAs were significantly older, were more likely to be female, had a higher CHA2DS2-VASc score, had larger LA volumes, and had a lower LA total emptying fraction (TEF). In multivariate analysis, only LA TEF [odds ratio (OR) 0.885, 95% confidence interval (CI) 0.846-0.926, P < 0.001] and the CHA2DS2-VASc score (OR 1.507, 95% CI 1.115-2.038, P = 0.008) remained independently associated with the presence of LVAs. CONCLUSION: Left atrial TEF and the CHA2DS2-VASc score were independently associated with the presence of LVAs found during LA electroanatomical mapping. These findings may help to improve pre-procedural prediction of pro-arrhythmogenic LVAs and to improve peri-procedural patient management.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Female , Male , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Heart Atria/diagnostic imaging , Heart Atria/surgery , Magnetic Resonance Imaging , Atrial Appendage/surgery , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Catheter Ablation/methods
6.
Res Sq ; 2023 May 17.
Article in English | MEDLINE | ID: mdl-37292932

ABSTRACT

Purpose: Mitral valve prolapse (MVP) is associated with left ventricle (LV) fibrosis, including the papillary muscles (PM), which is in turn linked to malignant arrhythmias. This study aims to evaluate comprehensive tissue characterization of the PM by cardiovascular magnetic resonance (CMR) imaging and its association with LV fibrosis observed by intraoperative biopsies. Methods: MVP patients with indication for surgery due to severe mitral regurgitation (n=19) underwent a preoperative CMR with characterization of the PM: dark-appearance on cine, T1 mapping, conventional bright blood (BB) and dark blood (DB) late gadolinium enhancement (LGE). CMR T1 mapping was performed on 21 healthy volunteers as controls. LV inferobasal myocardial biopsies were obtained in MVP patients and compared to CMR findings. Results: MVP patients (54±10 years old, 14 male) had a dark-appearance of the PM with higher native T1 and extracellular volume (ECV) values compared with healthy volunteers (1096±78ms vs 994±54ms and 33.9±5.6% vs 25.9±3.1%, respectively, p<0.001). Seventeen MVP patients (89.5%) had fibrosis by biopsy. BB-LGE+ in LV and PM was identified in 5 (26.3%) patients, while DB-LGE+ was observed in LV in 9 (47.4%) and in PM in 15 (78.9%) patients. DB-LGE+ in PM was the only technique that showed no difference with detection of LV fibrosis by biopsy. Posteromedial PM was more frequently affected than the anterolateral (73.7% vs 36.8%, p=0.039) and correlated with biopsy-proven LV fibrosis (Rho 0.529, p=0.029). Conclusions: CMR imaging in MVP patients referred for surgery shows a dark-appearance of the PM with higher T1 and ECV values compared with healthy volunteers. The presence of a positive DB-LGE at the posteromedial PM by CMR may serve as a better predictor of biopsy-proven LV inferobasal fibrosis than conventional CMR techniques.

7.
J Am Heart Assoc ; 12(6): e027971, 2023 03 21.
Article in English | MEDLINE | ID: mdl-36892055

ABSTRACT

Cardiac sarcoidosis can mimic any cardiomyopathy in different stages. Noncaseating granulomatous inflammation can be missed, because of the nonhomogeneous distribution in the heart. The current diagnostic criteria show discrepancies and are partly nonspecific and insensitive. Besides the diagnostic pitfalls, there are controversies in the understanding of the causes, genetic and environmental background, and the natural evolution of the disease. Here, we review the current pathophysiological aspects and gaps that are relevant for future cardiac sarcoidosis diagnostics and research.


Subject(s)
Cardiomyopathies , Myocarditis , Sarcoidosis , Humans , Myocarditis/diagnosis , Cardiomyopathies/diagnosis , Cardiomyopathies/genetics , Cardiomyopathies/therapy , Sarcoidosis/diagnosis , Sarcoidosis/therapy , Sarcoidosis/complications , Heart
8.
Int J Cardiol ; 376: 147-153, 2023 04 01.
Article in English | MEDLINE | ID: mdl-36791965

ABSTRACT

BACKGROUND: Cardiovascular magnetic resonance (CMR) imaging allows to combine pulmonary perfusion measurements and pulmonary venous angiography during a single-session examination with both imaging modules representing the basis for accurate diagnosis and therapeutic stratification of pulmonary vein (PV) stenosis. The present study investigated the clinical utility of dynamic pulmonary perfusion imaging integrated into a comprehensive CMR protocol for the evaluation of patients with suspected PV stenosis. METHODS: 162 patients with clinically suspected PV stenosis after catheter ablation of atrial fibrillation underwent a combined single-session CMR examination (cardiac cine imaging, dynamic pulmonary perfusion, and three-dimensional PV angiography). CMR angiography was used for visual grading of PV stenoses; dynamic pulmonary perfusion imaging was evaluated per lung lobe visually and quantitatively. RESULTS: All PV stenosis ≥90% showed a visible perfusion deficit of the corresponding lung lobe (60/60, 100%) while all PVs with luminal narrowing <50% exhibited normal pulmonary perfusion (680/680, 100%). However, every third 70-89% stenosis showed a normal pulmonary perfusion (10/31, 32%) while every fourth 50-69% PV stenosis was associated with hypoperfusion of the corresponding lung lobe (9/39, 23%). For quantitative pulmonary perfusion measurements, ROC analysis demonstrated high discriminatory power regarding PV stenosis detection with the highest AUC values for time-to-peak enhancement (cut-off value, 8.5 s). CONCLUSIONS: The combination of CMR angiography and CMR pulmonary perfusion allowed for assessment of the anatomical degree of PV stenosis and its hemodynamic impact on the pulmonary parenchymal level. Thus, the proposed comprehensive CMR protocol provided an efficient diagnostic work-up of patients with suspected PV stenosis.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Stenosis, Pulmonary Vein , Humans , Constriction, Pathologic , Pulmonary Veins/surgery , Magnetic Resonance Angiography/methods , Lung , Perfusion , Magnetic Resonance Spectroscopy
9.
Eur Radiol ; 33(1): 339-347, 2023 Jan.
Article in English | MEDLINE | ID: mdl-35984513

ABSTRACT

OBJECTIVES: In patients of advanced age, the feasibility of myocardial ischemia testing might be limited by age-related comorbidities and falling compliance abilities. Therefore, we aimed to test the accuracy of 3D cardiac magnetic resonance (CMR) stress perfusion in the elderly population as compared to reference standard fractional flow reserve (FFR). METHODS: Fifty-six patients at age 75 years or older (mean age 79 ± 4 years, 35 male) underwent 3D CMR perfusion imaging and invasive coronary angiography with FFR in 5 centers using the same study protocol. The diagnostic accuracy of CMR was compared to a control group of 360 patients aged below 75 years (mean age 61 ± 9 years, 262 male). The percentage of myocardial ischemic burden (MIB) relative to myocardial scar burden was further analyzed using semi-automated software. RESULTS: Sensitivity, specificity, and positive and negative predictive values of 3D perfusion CMR deemed similar for both age groups in the detection of hemodynamically relevant (FFR < 0.8) stenosis (≥ 75 years: 86%, 83%, 92%, and 75%; < 75 years: 87%, 80%, 82%, and 85%; p > 0.05 all). While MIB was larger in the elderly patients (15% ± 17% vs. 9% ± 13%), the diagnostic accuracy of 3D CMR perfusion was high in both elderly and non-elderly populations to predict pathological FFR (AUC: 0.906 and 0.866). CONCLUSIONS: 3D CMR perfusion has excellent diagnostic accuracy for the detection of hemodynamically relevant coronary stenosis, independent of patient age. KEY POINTS: • The increasing prevalence of coronary artery disease in elderly populations is accompanied with a larger ischemic burden of the myocardium as compared to younger individuals. • 3D cardiac magnetic resonance perfusion imaging predicts pathological fractional flow reserve in elderly patients aged ≥ 75 years with high diagnostic accuracy. • Ischemia testing with 3D CMR perfusion imaging has similarly high accuracy in the elderly as in younger patients and it might be particularly useful when other non-invasive techniques are limited by aging-related comorbidities and falling compliance abilities.


Subject(s)
Coronary Artery Disease , Coronary Stenosis , Fractional Flow Reserve, Myocardial , Myocardial Perfusion Imaging , Humans , Male , Aged , Aged, 80 and over , Middle Aged , Coronary Artery Disease/diagnosis , Myocardial Perfusion Imaging/methods , Severity of Illness Index , Coronary Angiography/methods , Predictive Value of Tests , Perfusion , Magnetic Resonance Spectroscopy
10.
Magn Reson Med ; 89(5): 2005-2013, 2023 05.
Article in English | MEDLINE | ID: mdl-36585913

ABSTRACT

PURPOSE: To evaluate a silent MR active catheter tracking sequence that allows conducting catheter interventions with low acoustic noise levels. METHODS: To reduce the acoustic noise associated with MR catheter tracking, we implemented a technique previously used in conventional MRI. The gradient waveforms are modified to reduce the sound pressure level (SPL) and avoid acoustic resonances of the MRI system. The efficacy of the noise reduction was assessed by software-predicted SPL and verified by measurements. Furthermore, the quality of the catheter tracking signal was assessed in a phantom experiment and during interventional cardiovascular MRI sessions targeted at isthmus-related flutter ablation. RESULTS: The maximum measured SPL in the scanner room was 104 dB(A) for real-time imaging, and 88 dB(A) and 69 dB(A) for conventional and silent tracking, respectively. The SPL measured at different positions in the MR suite using silent tracking were 65-69 dB(A), and thus within the range of a normal conversation. Equivalent signal quality and tracking accuracy were obtained using the silent variant of the catheter tracking sequence. CONCLUSION: Our results indicate that silent MR catheter tracking capabilities are identical to conventional catheter tracking. The achieved acoustic noise reduction comes at no penalty in terms of tracking quality or temporal resolution, improves comfort and safety, and can overcome the need for MR-compatible communication equipment and background noise suppression during the actual interventional procedure.


Subject(s)
Magnetic Resonance Imaging, Interventional , Magnetic Resonance Imaging , Magnetic Resonance Imaging/methods , Catheters , Software , Magnetic Resonance Imaging, Interventional/methods , Phantoms, Imaging
11.
J Cardiovasc Magn Reson ; 24(1): 70, 2022 Dec 12.
Article in English | MEDLINE | ID: mdl-36503589

ABSTRACT

BACKGROUND: Pulmonary vein (PV) stenosis represents a rare but serious complication following radiofrequency ablation of atrial fibrillation with a comprehensive diagnosis including morphological stenosis grading together with the assessment of its functional consequences being imperative within the relatively narrow window for therapeutic intervention. The present study determined the clinical utility of a combined, single-session cardiovascular magnetic resonance (CMR) imaging protocol integrating pulmonary perfusion and PV angiographic assessment for pre-procedural planning and follow-up of patients referred for interventional PV stenosis treatment. METHODS: CMR examinations (cine imaging, dynamic pulmonary perfusion, three-dimensional PV angiography) were performed in 32 consecutive patients prior to interventional treatment of PV stenosis and at 1-day and 3-months follow-up. Degree of PV stenosis was visually determined on CMR angiography; visual and quantitative analysis of pulmonary perfusion imaging was done for all five lung lobes. RESULTS: Interventional treatment of PV stenosis achieved an acute procedural success rate of 90%. Agreement between visually evaluated pulmonary perfusion imaging and the presence or absence of a ≥ 70% PV stenosis was nearly perfect (Cohen's kappa, 0.96). ROC analysis demonstrated high discriminatory power of quantitative pulmonary perfusion measurements for the detection of ≥ 70% PV stenosis (AUC for time-to-peak enhancement, 0.96; wash-in rate, 0.93; maximum enhancement, 0.90). Quantitative pulmonary perfusion analysis proved a very large treatment effect attributable to successful PV revascularization already after 1 day. CONCLUSION: Integration of CMR pulmonary perfusion imaging into the clinical work-up of patients with PV stenosis allowed for efficient peri-procedural stratification and follow-up evaluation of revascularization success.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Stenosis, Pulmonary Vein , Humans , Stenosis, Pulmonary Vein/diagnostic imaging , Stenosis, Pulmonary Vein/etiology , Stenosis, Pulmonary Vein/therapy , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Catheter Ablation/adverse effects , Constriction, Pathologic/etiology , Constriction, Pathologic/pathology , Constriction, Pathologic/surgery , Predictive Value of Tests , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Lung/diagnostic imaging , Magnetic Resonance Spectroscopy
12.
Int J Cardiol Heart Vasc ; 38: 100939, 2022 Feb.
Article in English | MEDLINE | ID: mdl-35024429

ABSTRACT

INTRODUCTION: Preprocedural cardiovascular magnetic resonance (CMR) or computed tomography (CT) imaging of the left atrium/pulmonary veins is usually employed to guide catheter ablation of atrial fibrillation (AFCA). Incidental findings (IFs) are common on cardiac imaging prior to AFCA. However, previous studies have mainly focused on extracardiac IFs detected on CT scan. We aimed to assess the prevalence of relevant cardiac and extracardiac IFs on routine preprocedural CMR in a large patient cohort scheduled for first-time AFCA and report its impact on clinical decision-making and management. METHODS AND RESULTS: We included 2000 consecutive patients (62 ± 10 years; 59% male) who underwent CMR prior to first-time AFCA between April 2015 and March 2019. Among these patients 172 (8.6%) had a total of 184 major IFs. Detection of major IFs resulted in cancellation of the scheduled AFCA procedure in 88 patients (4.4%). Forty-two patients (2.1%) have never been ablated, 46 (2.3%) underwent postponed AFCA after a median time of 83 (32-213) days. The remaining 84 patients (4.2%) underwent an individualized approach to AFCA. The most common major IFs were accessory or anomalous PVs in 76 (3.8%), extracardiac abnormalities suspicious of malignancy in 29 (1.5%), and positive stress perfusion imaging in 19 (7.2% of 261 tested) patients. In 19 patients (1.0%) preprocedural CMR provided the diagnosis of a previously unknown structural cardiac disease. CONCLUSIONS: Unexpected relevant findings on routine preprocedural CMR affected clinical decision-making and management in 8.6% of patients scheduled for first-time AFCA. However, whether preprocedural CMR imaging may improve overall clinical outcome needs to be addressed in future research.

13.
Europace ; 24(1): 12-19, 2022 01 04.
Article in English | MEDLINE | ID: mdl-34279613

ABSTRACT

AIMS: To establish a cardiovascular magnetic resonance (CMR)-based prediction model for complete systolic left ventricular ejection fraction (LVEF) recovery for the distinction of 'arrhythmia-induced' from 'arrhythmia-mediated' cardiomyopathy in patients with atrial tachyarrhythmias. METHODS AND RESULTS: Two hundred and fifty-three tachyarrhythmia patients referred for catheter ablation were enrolled and underwent CMR baseline imaging; patients with a reduced LVEF <50% at baseline and CMR imaging at 3-month follow-up after successful rhythm restoration constituted the final study population (n = 134). CMR at baseline consisted of standard functional cine imaging, determination of extracellular volume, and late gadolinium enhancement (LGE) imaging; follow-up CMR comprised standard functional cine imaging. Left ventricular end-diastolic volume index (LVEDVI) measurements were categorized in 'opposite', 'normal', and 'enlarged'. At follow-up, 80% (107/134) presented with complete LVEF recovery, while in 20% (27/134) persistent LVEF impairment was observed. LVEDVI and LGE were independent predictors of complete LVEF recovery with LGE adding significant incremental value on logistic regression modelling. Model-derived probabilities for complete LVEF recovery in LVEDVI categories of opposite, normal, and enlarged for LGE negativity and positivity were 94%, 85%, and 29% and 77%, 55%, and 8%, respectively. CONCLUSION: CMR-derived assessment of LVEDVI category and LGE allowed for identification of arrhythmia-induced cardiomyopathy with acceptable discriminative performance. Probabilities for complete LVEF recovery for the combination of opposite LVEDVI/LGE negativity and enlarged LVEDVI/LGE positivity were 94% and 8%, respectively. The CMR-based prediction model of complete LVEF recovery can be used to perform upfront stratification in atrial tachyarrhythmia-related LVEF impairment.


Subject(s)
Contrast Media , Gadolinium , Humans , Magnetic Resonance Imaging, Cine , Magnetic Resonance Spectroscopy , Predictive Value of Tests , Stroke Volume , Tachycardia , Ventricular Function, Left
14.
JACC Case Rep ; 3(16): 1756-1759, 2021 Nov 17.
Article in English | MEDLINE | ID: mdl-34825204

ABSTRACT

A 25-year-old male patient with highly symptomatic, monomorphic, premature ventricular contractions presented for repeat ablation after failed endocardial ablation. Three weeks after excessive endocardial and epicardial ablation on the left ventricular summit, the patient was admitted again with tamponade following a pseudoaneurysm on the ablation site. (Level of Difficulty: Advanced.).

15.
J Cardiovasc Magn Reson ; 23(1): 87, 2021 07 08.
Article in English | MEDLINE | ID: mdl-34233708

ABSTRACT

BACKGROUND: Four-dimensional cardiovascular magnetic resonance (CMR) flow assessment (4D flow) allows to derive volumetric quantitative parameters in mitral regurgitation (MR) using retrospective valve tracking. However, prior studies have been conducted in functional MR or in patients with congenital heart disease, thus, data regarding the usefulness of 4D flow CMR in case of a valve pathology like mitral valve prolapse (MVP) are scarce. This study aimed to evaluate the clinical utility of cine-guided valve segmentation of 4D flow CMR in assessment of MR in MVP when compared to standardized routine CMR and transthoracic echocardiography (TTE). METHODS: Six healthy subjects and 54 patients (55 ± 16 years; 47 men) with MVP were studied. TTE severity grading used a multiparametric approach resulting in mild/mild-moderate (n = 12), moderate-severe (n = 12), and severe MR (n = 30). Regurgitant volume (RVol) and regurgitant fraction (RF) were also derived using standard volumetric CMR and 4D flow CMR datasets with direct measurement of regurgitant flow (4DFdirect) and indirect calculation using the formula: mitral valve forward flow - left ventricular outflow tract stroke volume (4DFindirect). RESULTS: There was moderate to strong correlation between methods (r = 0.59-0.84, p < 0.001), but TTE proximal isovelocity surface area (PISA) method showed higher RVol as compared with CMR techniques (PISA vs. CMR, mean difference of 15.8 ml [95% CI 9.9-21.6]; PISA vs. 4DFindirect, 17.2 ml [8.4-25.9]; PISA vs. 4DFdirect, 27.9 ml [19.1-36.8]; p < 0.001). Only indirect CMR methods (CMR vs. 4DFindirect) showed moderate to substantial agreement (Lin's coefficient 0.92-0.97) without significant bias (mean bias 1.05 ± 26 ml [- 50 to 52], p = 0.757). Intra- and inter-observer reliability were good to excellent for all methods (ICC 0.87-0.99), but with numerically lower coefficient of variation for indirect CMR methods (2.5 to 12%). CONCLUSIONS: In the assessment of patients with MR and MVP, cine-guided valve segmentation 4D flow CMR is feasible and comparable to standard CMR, but with lower RVol when TTE is used as reference. 4DFindirect quantification has higher intra- and inter-technique agreement than 4DFdirect quantification and might be used as an adjunctive technique for cross-checking MR quantification in MVP.


Subject(s)
Mitral Valve Insufficiency , Mitral Valve Prolapse , Humans , Magnetic Resonance Imaging, Cine , Magnetic Resonance Spectroscopy , Male , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Prolapse/diagnostic imaging , Predictive Value of Tests , Reproducibility of Results , Retrospective Studies , Severity of Illness Index
16.
Eur Heart J Case Rep ; 5(4): ytab094, 2021 Apr.
Article in English | MEDLINE | ID: mdl-34124545

ABSTRACT

BACKGROUND: Interventricular septal perforation is an extremely rare complication of radiofrequency ablation (RFA), with an incidence of 1%. The most common mechanism is a 'steam pop', which can be described as 'mini-explosions' of gas bubbles. Data for percutaneous repair of cardiac perforations due to RFA are limited. CASE SUMMARY: A 78-year-old female patient was referred to our department for the treatment of two iatrogenic ventricular septal defects (VSDs) following radiofrequency ablation (RFA) of premature ventricular contractions. One week post-ablation, chest pain and progressive dyspnoea occurred. Transthoracic echocardiography detected a VSD, diameter 10 mm. Hence, iatrogenic, RFA-related myocardial injury was considered the most likely cause of VSD, and the patient was referred to our tertiary care centre for surgical repair. Cardiovascular magnetic resonance (CMR) imaging demonstrated border-zone oedema of the VSD only and confirmed the absence of necrotic tissue boundaries, and the patient was deemed suitable for percutaneous device closure. Laevocardiography identified an additional, smaller muscular defect that cannot be explained by analysing the Carto-Map. Both defects could be successfully closed percutaneously using two Amplatzer VSD occluder devices. DISCUSSION: In conclusion, this case demonstrates a successful percutaneous closure of a VSD resulting from RFA using an Amplatzer septal occluder device. CMR might improve tissue characterization of the VSD borders and support the decision if to opt for interventional or surgical closure.

18.
Int J Cardiovasc Imaging ; 37(6): 1947-1959, 2021 Jun.
Article in English | MEDLINE | ID: mdl-33616785

ABSTRACT

Three-dimensional transthoracic echocardiography (3D-TTE) provides a semi-automated proximal isovelocity surface area method (3D-PISA) to obtain quantitative parameters. Data assessing regurgitation severity in mitral valve prolapse (MVP) are scarce, so we assessed the 3D-PISA method compared with 2D-PISA and cardiovascular magnetic resonance (CMR) and the role of an eccentricity index. We evaluated the 3D-PISA method for assessing MR in 54 patients with MVP (57 ± 14 years; 42 men; 12 mild/mild-moderate; 12 moderate-severe; and 30 severe MR). Role of an asymmetric (i.e. eccentricity index ≥ 1.25) flow convergence region (FCR) and inter-modality consistency were then assessed. 3D-PISA derived regurgitant volume (RVol) showed a good correlation with 2D-PISA and CMR derived parameters (r = 0.86 and r = 0.81, respectively). The small mean differences with 2D-PISA derived RVol did not reach statistical significance in overall population (5.7 ± 23 ml, 95% CI - 0.6 to 12; p = 0.08) but differed in those with asymmetric 3D-FCR (n = 21; 2D-PISA: 72 ± 36 ml vs. 3D-PISA: 93 ± 47 ml; p = 0.001). RVol mean values were higher using PISA methods (CMR 57 ± 33 ml; 2D-PISA 73 ± 39 ml; and 3D-PISA 79 ± 45 ml) and an overestimation was observed when CMR was used as reference (2D-PISA vs. CMR: mean difference: 15.8 ml [95% CI 10-22, p < 0.001]; and 3D-PISA vs. CMR: 21.5 ml [95% CI 14-29, p < 0.001]). Intra- and inter-observer reliability was excellent (ICC 0.91-0.99), but with numerically lower coefficient of variation for 3D-PISA (8%-10% vs. 2D-PISA: 12%-16%). 3D-PISA method for assessing regurgitation in MVP may enable analogous evaluation compared to standard 2D-PISA, but with overestimation in case of asymmetric FCR or when CMR is used as reference method.


Subject(s)
Echocardiography, Three-Dimensional , Mitral Valve Insufficiency , Mitral Valve Prolapse , Echocardiography, Doppler, Color , Humans , Male , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/etiology , Mitral Valve Prolapse/diagnostic imaging , Predictive Value of Tests , Reproducibility of Results , Severity of Illness Index
19.
Cardiol J ; 28(4): 558-565, 2021.
Article in English | MEDLINE | ID: mdl-31909472

ABSTRACT

BACKGROUND: To achieve high image quality of cardiovascular magnetic resonance (CMR) pulmonary vein (PV) angiography prior catheter ablation in patients with atrial fibrillation, optimal timing of the angiographic sequence during contrast agent passage is important. The present study identified influential cardiovascular parameters for prediction of contrast agent travel time. METHODS: One hundred six consecutive patients underwent a CMR examination including three-dimensional (3D) contrast-enhanced PV angiography with real-time bolus tracking prior to catheter ablation. Correct scan timing was characterized by relative signal enhancement measurements in the pulmonary artery, left atrium (LA), and ascending aorta. Furthermore, left- and right-ventricular function, left- and right-atrial dimensions, presence of mitral or tricuspid insufficiencies, and main pulmonary artery diameter were determined. RESULTS: The highest relative signal enhancement in LA demonstrated optimal scan timing. Contrast agent travel time showed wide variability (range: 12-42 s; mean: 18 ± 4 s). On univariate analysis, most cardiovascular parameters correlated with contrast agent travel time while on multivariate analysis left- and right-ventricular function remained the only independent predictors, but overall a poor fit to the data (adjusted R2, 27.5%) was found. CONCLUSIONS: Contrast agent travel time was mainly influenced by left- and right-ventricular function but prediction models poorly fitted the data. Thus, 3D PV angiography prior to PV ablation procedures necessitates real-time assessment, with visual determination of individual contrast agent passage time to ensure consistently high CMR image quality.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Heart Atria/diagnostic imaging , Heart Atria/surgery , Humans , Imaging, Three-Dimensional , Magnetic Resonance Angiography , Magnetic Resonance Spectroscopy , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery
20.
J Cardiovasc Magn Reson ; 22(1): 32, 2020 05 11.
Article in English | MEDLINE | ID: mdl-32389126

ABSTRACT

BACKGROUND: Data on the usefulness of cardiovascular magnetic resonance (CMR) imaging for clinical decision making in patients with an implanted cardioverter defibrillator (ICD) are scarce. The present study determined the impact of CMR imaging on diagnostic stratification and treatment decisions in ICD patients presenting with electrical instability or progressive heart failure symptoms. METHODS: 212 consecutive ICD patients underwent 1.5 T CMR combining diagnostic imaging modules tailored to the individual clinical indication (ventricular function assessment, myocardial tissue characterization, adenosine stress-perfusion, 3D-contrast-enhanced angiography); four CMR examinations (4/212, 2%) were excluded due to non-diagnostic CMR image quality. The resultant change in diagnosis or clinical management was determined in the overall population and compared between ICD patients for primary (115/208, 55%) or secondary prevention (93/208, 45%). Referral indication consisted of documented ventricular tachycardia, inadequate device therapy or progressive heart failure symptoms. RESULTS: Overall, CMR imaging data changed diagnosis in 40% (83/208) with a significant difference between primary versus secondary prevention ICD patients (37/115, 32% versus 46/93, 49%, respectively; p = 0.01). The information gain from CMR led to an overall change in treatment in 21% (43/208) with a similar distribution in primary versus secondary prevention ICD patients (25/115,22% versus 18/93,19%, p = 0.67). The effect on treatment change was highest in patients initially scheduled for ventricular tachycardia ablation procedure (18/141, 13%) with revision of the treatment plan to medical therapy or coronary revascularization. CONCLUSIONS: CMR imaging in ICD patients presenting with electrical instability or worsening heart failure symptoms provided diagnostic or management-changing information in a considerable proportion (40% and 21%, respectively).


Subject(s)
Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable , Electric Countershock/instrumentation , Heart Failure/therapy , Magnetic Resonance Imaging, Cine , Tachycardia, Ventricular/therapy , Aged , Catheter Ablation , Clinical Decision-Making , Disease Progression , Female , Heart Failure/diagnostic imaging , Heart Failure/physiopathology , Humans , Male , Middle Aged , Predictive Value of Tests , Primary Prevention , Secondary Prevention , Tachycardia, Ventricular/diagnostic imaging , Tachycardia, Ventricular/physiopathology , Time Factors , Treatment Outcome , Ventricular Function, Left
SELECTION OF CITATIONS
SEARCH DETAIL
...