1.
Biomed Microdevices ; 15(1): 151-60, 2013 Feb.
Article in English | MEDLINE | ID: mdl-22992979

ABSTRACT

Implantable sensors for continuous glucose monitoring hold great potential for optimal diabetes management. This is often undermined by a variety of issues associated with: (1) negative tissue response; (2) poor sensor performance; and (3) lack of device miniaturization needed to reduce implantation trauma. Herein, we report our initial results towards constructing an implantable device that simultaneously address all three aforementioned issues. In terms of device miniaturization, a highly miniaturized CMOS (complementary metal-oxide-semiconductor) potentiostat and signal processing unit was employed (with a combined area of 0.665 mm(2)). The signal processing unit converts the current generated by a transcutaneous, Clark-type amperometric sensor to output frequency in a linear fashion. The Clark-type amperometric sensor employs stratification of five functional layers to attain a well-balanced mass transfer which in turn yields a linear sensor response from 0 to 25 mM of glucose concentration, well beyond the physiologically observed (2 to 22 mM) range. In addition, it is coated with a thick polyvinyl alcohol (PVA) hydrogel with embedded poly(lactic-co-glycolic acid) (PLGA) microspheres intended to provide continuous, localized delivery of dexamethasone to suppress inflammation and fibrosis. In vivo evaluation in rat model has shown that the transcutaneous sensor system reproducibly tracks repeated glycemic events. Clarke's error grid analysis on the as-obtained glycemic data has indicated that all of the measured glucose readings fell in the desired Zones A & B and none fell in the erroneous Zones C, D and E. Such reproducible operation of the transcutaneous sensor system, together with low power (140 µW) consumption and capability for current-to-frequency conversion renders this a versatile platform for continuous glucose monitoring and other biomedical sensing devices.


Subject(s)
Blood Glucose Self-Monitoring/instrumentation , Glucose/analysis , Miniaturization/instrumentation , Prostheses and Implants , Skin , Animals , Biosensing Techniques , Electrochemistry , Lactic Acid/chemistry , Male , Metals/chemistry , Oxides/chemistry , Polyglycolic Acid/chemistry , Polylactic Acid-Polyglycolic Acid Copolymer , Polyvinyl Alcohol/chemistry , Rats , Rats, Sprague-Dawley , Semiconductors
2.
Sensors (Basel) ; 12(10): 13402-16, 2012 Oct 01.
Article in English | MEDLINE | ID: mdl-23202001

ABSTRACT

The performance of implantable electrochemical glucose sensors is highly dependent on the flux-limiting (glucose, H(2)O(2), O(2)) properties of their outer membranes. A careful understanding of the diffusion profiles of the participating species throughout the sensor architecture (enzyme and membrane layer) plays a crucial role in designing a robust sensor for both in vitro and in vivo operation. This paper reports the results from the mathematical modeling of Clark's first generation amperometric glucose sensor coated with layer-by-layer assembled outer membranes in order to obtain and compare the diffusion profiles of various participating species and their effect on sensor performance. Devices coated with highly glucose permeable (HAs/Fe(3+)) membranes were compared with devices coated with PSS/PDDA membranes, which have an order of magnitude lower permeability. The simulation showed that the low glucose permeable membrane (PSS/PDDA) sensors exhibited a 27% higher amperometric response than the high glucose permeable (HAs/Fe(3+)) sensors. Upon closer inspection of H(2)O(2)diffusion profiles, this non-typical higher response from PSS/PDDA is not due to either a larger glucose flux or comparatively larger O(2) concentrations within the sensor geometry, but rather is attributed to a 48% higher H(2)O(2) concentration in the glucose oxidase enzyme layer of PSS/PDDA coated sensors as compared to HAs/Fe(3+) coated ones. These simulated results corroborate our experimental findings reported previously. The high concentration of H(2)O(2) in the PSS/PDDA coated sensors is due to the low permeability of H(2)O(2) through the PSS/PDDA membrane, which also led to an undesired increase in sensor response time. Additionally, it was found that this phenomenon occurs for all enzyme thicknesses investigated (15, 20 and 25 nm), signifying the need for a holistic approach in designing outer membranes for amperometric biosensors.


Subject(s)
Biosensing Techniques/instrumentation , Coated Materials, Biocompatible/chemistry , Glucose/analysis , Models, Theoretical , Electrodes, Implanted , Humans , Infusion Pumps, Implantable , Insulin Infusion Systems , Membranes, Artificial
3.
J Diabetes Sci Technol ; 4(6): 1540-62, 2010 Nov 01.
Article in English | MEDLINE | ID: mdl-21129353

ABSTRACT

Devices for continuous glucose monitoring (CGM) are currently a major focus of research in the area of diabetes management. It is envisioned that such devices will have the ability to alert a diabetes patient (or the parent or medical care giver of a diabetes patient) of impending hypoglycemic/hyperglycemic events and thereby enable the patient to avoid extreme hypoglycemic/hyperglycemic excursions as well as minimize deviations outside the normal glucose range, thus preventing both life-threatening events and the debilitating complications associated with diabetes. It is anticipated that CGM devices will utilize constant feedback of analytical information from a glucose sensor to activate an insulin delivery pump, thereby ultimately realizing the concept of an artificial pancreas. Depending on whether the CGM device penetrates/breaks the skin and/or the sample is measured extracorporeally, these devices can be categorized as totally invasive, minimally invasive, and noninvasive. In addition, CGM devices are further classified according to the transduction mechanisms used for glucose sensing (i.e., electrochemical, optical, and piezoelectric). However, at present, most of these technologies are plagued by a variety of issues that affect their accuracy and long-term performance. This article presents a critical comparison of existing CGM technologies, highlighting critical issues of device accuracy, foreign body response, calibration, and miniaturization. An outlook on future developments with an emphasis on long-term reliability and performance is also presented.


Subject(s)
Blood Glucose/metabolism , Diabetes Mellitus/diagnosis , Monitoring, Ambulatory , Biomarkers/blood , Diabetes Mellitus/blood , Diabetes Mellitus/drug therapy , Equipment Design , Forecasting , Humans , Insulin Infusion Systems , Miniaturization , Monitoring, Ambulatory/instrumentation , Monitoring, Ambulatory/methods , Monitoring, Ambulatory/trends , Predictive Value of Tests , Reproducibility of Results , Signal Processing, Computer-Assisted , Time Factors
4.
Biosens Bioelectron ; 25(7): 1553-65, 2010 Mar 15.
Article in English | MEDLINE | ID: mdl-20042326

ABSTRACT

The development of implantable biosensors for continuous monitoring of metabolites is an area of sustained scientific and technological interests. On the other hand, nanotechnology, a discipline which deals with the properties of materials at the nanoscale, is developing as a potent tool to enhance the performance of these biosensors. This article reviews the current state of implantable biosensors, highlighting the synergy between nanotechnology and sensor performance. Emphasis is placed on the electrochemical method of detection in light of its widespread usage and substantial nanotechnology based improvements in various aspects of electrochemical biosensor performance. Finally, issues regarding toxicity and biocompatibility of nanomaterials, along with future prospects for the application of nanotechnology in implantable biosensors, are discussed.


Subject(s)
Biosensing Techniques/instrumentation , Biosensing Techniques/trends , Nanotechnology/instrumentation , Nanotechnology/trends , Prostheses and Implants/trends , Transducers/trends , Equipment Design/trends , Forecasting , Systems Integration
5.
J Diabetes Sci Technol ; 3(4): 863-74, 2009 Jul 01.
Article in English | MEDLINE | ID: mdl-20144336

ABSTRACT

BACKGROUND: High linearities, sensitivities, and low oxygen dependence constitute prime requisites for electrochemical glucose sensors. However, for implantable sensors the need to control tissue inflammation requires the use outer membranes that permit inward analyte diffusion while continuously releasing anti-inflammatory drugs and other tissue response-modifying (TRM) agents. We have shown previously that while outer membranes based on layer-by-layer (LBL) assembly enhance linearity, poly(vinyl alcohol)(PVA) hydrogels loaded with TRM-containing microspheres enable a significant reduction in tissue inflammation. This article discusses amperometric performance of glucose sensors coated with stacked LBL/PVA hydrogel outer membranes. METHODS: Sensors were fabricated by immobilizing glucose oxidase enzyme on a 50-microm platinum wire followed by deposition of stacked LBL/PVA hydrogel outer membranes. The sensor response to various glucose concentrations was determined by applying 0.7 V vs an Ag/AgCl reference electrode in phosphate-buffered saline (37 degrees C). Michaelis-Menten analysis was performed to quantify sensor performance in terms of linearity (K(m,glu)(app)) and oxygen dependence (K(m,O(2))(app)/[Glucose]). RESULTS: When overlaid onto LBL-assembled outer membranes, PVA hydrogels improved sensor linearity by 60% from 10 to 16 mM of glucose and resulted in a twofold decrease in oxygen dependence. CONCLUSIONS: Enhancement in the performance of a PVA-coated sensor is attributed to the oxygen-storing capability of PVA hydrogel due to the formation of hydrophobic domains during its freezing and thawing employed to physical cross-link the PVA. Such membranes with the capability to release TRMs continuously while storing oxygen constitute a major improvement over current outer membrane technologies.


Subject(s)
Biosensing Techniques , Glucose/analysis , Hydrogels , Biocompatible Materials , Infusion Pumps, Implantable , Insulin Infusion Systems , Microspheres , Polyvinyl Alcohol/chemistry