ABSTRACT
Extreme heat is a current and growing global health concern. Current heat exposure models include meteorological and human factors that dictate heat stress, comfort, and risk of illness. However, radiation models simplify the human body to a cylinder, while convection ones provide conflicting predictions. To address these issues, we introduce a new method to characterize human exposure to extreme heat with unprecedented detail. We measure heat loads on 35 body surface zones using an outdoor thermal manikin ("ANDI") alongside an ultrasonic anemometer array and integral radiation measurements (IRM). We show that regardless of body orientation, IRM and ANDI agree even under high solar conditions. Further, body parts can be treated as cylinders, even in highly turbulent flow. This geometry-rooted insight yields a whole-body convection correlation that resolves prior conflicts and is valid for diverse indoor and outdoor wind flows. Results will inform decision-making around heat protection, adaptation, and mitigation.
Subject(s)
Extreme Heat , Humans , Manikins , WindABSTRACT
As populations and temperatures of urban areas swell, more people face extreme heat and are at increasing risk of adverse health outcomes. Radiation accounts for much of human heat exposure but is rarely used as heat metric due to a lack of cost-effective and accurate sensors. To this end, we fuse the concepts of a three-globe radiometer-anemometer with a cylindrical human body shape representation, which is more realistic than a spherical representation. Using cost-effective and readily available materials, we fabricated two combinations of three cylinders with varying surface properties. These simple devices measure the convection coefficient and the shortwave and longwave radiative fluxes. We tested the devices in a wind tunnel and at fourteen outdoor sites during July 2023's record-setting heat wave in Tempe, Arizona. The average difference between pedestrian-level mean radiant temperature (MRT) measured using research-grade 3-way net radiometers and the three-cylinder setup was 0.4 ± 3.0 °C ( ± 1 SD). At most, we observed a 10 °C MRT difference on a white roof site with extreme MRT values (70 °C to 80 °C), which will be addressed through discussed design changes to the system. The measured heat transfer coefficient can be used to calculate wind speed below 2 m·s-1; thus, the three cylinders combined also serve as a low-speed anemometer. The novel setup could be used in affordable biometeorological stations and deployed across urban landscapes to build human-relevant heat sensing networks.