Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 44
Filter
1.
J Med Syst ; 44(3): 56, 2020 Jan 24.
Article in English | MEDLINE | ID: mdl-31980955

ABSTRACT

Motion tracking software for assessing laparoscopic surgical proficiency has been proven to be effective in differentiating between expert and novice performances. However, with several indices that can be generated from the software, there is no set threshold that can be used to benchmark performances. The aim of this study was to identify the best possible algorithm that can be used to benchmark expert, intermediate and novice performances for objective evaluation of psychomotor skills. 12 video recordings of various surgeons were collected in a blinded fashion. Data from our previous study of 6 experts and 23 novices was also included in the analysis to determine thresholds for performance. Video recording were analyzed both by the Kinovea 0.8.15 software and a blinded expert observer using the CAT form. Multiple algorithms were tested to accurately identify expert and novice performances. ½ L + [Formula: see text] A + [Formula: see text] J scoring of path length, average movement and jerk index respectively resulted in identifying 23/24 performances. Comparing the algorithm to CAT assessment yielded in a linear regression coefficient R2 of 0.844. The value of motion tracking software in providing objective clinical evaluation and retrospective analysis is evident. Given the prospective use of this tool the algorithm developed in this study proves to be effective in benchmarking performances for psychomotor skills evaluation.


Subject(s)
Algorithms , Cholecystectomy, Laparoscopic/methods , Clinical Competence , Movement/physiology , Software , Task Performance and Analysis , Humans , Video Recording
2.
Surg Endosc ; 34(7): 2947-2953, 2020 07.
Article in English | MEDLINE | ID: mdl-31451918

ABSTRACT

BACKGROUND: Laparoscopic suturing can be technically challenging and requires extensive training to achieve competency. To date no specific and objective assessment method for laparoscopic suturing and knot tying is available that can guide training and monitor performance in these complex surgical skills. In this study we aimed to develop a laparoscopic suturing competency assessment tool (LS-CAT) and assess its inter-observer reliability. METHODS: We developed a bespoke CAT tool for laparoscopic suturing through a structured, mixed methodology approach, overseen by a steering committee with experience in developing surgical assessment tools. A wide Delphi consultation with over twelve experts in laparoscopic surgery guided the development stages of the tool. Following, subjects with different levels of laparoscopic expertise were included to evaluate this tool, using a simulated laparoscopic suturing task which involved placing of two surgical knots. A research assistant video recorded and anonymised each performance. Two blinded expert surgeons assessed the anonymised videos using the developed LS-CAT. The LS-CAT scores of the two experts were compared to assess the inter-observer reliability. Lastly, we compared the subjects' LS-CAT performance scores at the beginning and end of their learning curve. RESULTS: This study evaluated a novel LS-CAT performance tool, comprising of four tasks. Thirty-six complete videos were analysed and evaluated with the LS-CAT, of which the scores demonstrated excellent inter-observer reliability. Cohen's Kappa analysis revealed good to excellent levels of agreement for almost all tasks of both instrument handling and tissue handling (0.87; 0.77; 0.75; 0.86; 0.85, all with p < 0.001). Subjects performed significantly better at the end of their learning curve compared to their first attempt for all LS-CAT items (all with p < 0.001). CONCLUSIONS: We developed the LS-CAT, which is a laparoscopic suturing grading matrix, with excellent inter-rater reliability and to discriminate between experience levels. This LS-CAT has a potential for wider use to objectively assess laparoscopic suturing skills.


Subject(s)
Clinical Competence , Laparoscopy/education , Suture Techniques/education , Humans , Learning Curve , Reproducibility of Results , Surgeons/education , Sutures , Video Recording
3.
J Laparoendosc Adv Surg Tech A ; 29(11): 1419-1426, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31613679

ABSTRACT

Background: The eoSim® laparoscopic augmented reality (AR) simulator has instrument tracking capabilities that may be suitable for implementation in laparoscopic training. The objective is to assess face, content, and construct validity of this simulator for basic laparoscopic skills training. Methods: Participants were divided into three groups: novices (no training), intermediates (<50 laparoscopic procedures), and experts (>50 laparoscopic procedures). Three basic tasks were completed on the simulator: thread transfer (1), cyst dissection (2), and tube ligation (3). A questionnaire was completed on realism, didactic value, and usability of the simulator. Measured outcome parameters were as follows: time, distance, time off screen, average speed, acceleration, and smoothness. Results: Mean ± standard deviation scores on realism were positive (Task 1 or T1; 3.9 ± 0.7, P = .13, T2; 3.7 ± 0.7, P = .07, T3; 3.7 ± 0.07), as well as didactic value (T1; 3.9 ± 0.8, P = .71, T2; 3.9 ± 0.8, P = .31, T3; 4.0 ± 0.8, P = .40). Usability was valued the highest, with mean scores between 3.9 and 4.3 (T1; P = .71, T2; P = .80, T3; P = .85). Scores did not differ significantly between groups. Experts were significantly faster (Task 1; P < .001, Task 2; P = .042, Task 3: P < .001) with higher handling speed for tasks 2 and 3 (Task 1; P = .20, task 2; P = .034, task 3; P = .049). Results for other outcome parameters also indicated experts had better instrument control and efficiency than novices, although these differences did not reach statistical significance. Conclusions: The eoSim laparoscopic AR simulator is regarded as a realistic, accessible, and useful tool for the training of basic laparoscopic skills, with good face validity. Construct validity of the eoSim AR simulator was demonstrated on several core variables, but not all.


Subject(s)
Augmented Reality , Clinical Competence , Laparoscopy/education , Simulation Training/methods , Adult , Cysts/surgery , Dissection , Female , Humans , Male , Middle Aged , Reproducibility of Results , Software , Sterilization, Tubal , Surveys and Questionnaires , Young Adult
4.
Surg Endosc ; 33(11): 3635-3643, 2019 11.
Article in English | MEDLINE | ID: mdl-30671668

ABSTRACT

BACKGROUND: The purpose of this study was to validate the eoSim, an affordable and mobile inanimate laparoscopic simulator with instrument tracking capabilities, regarding face, content and construct validity on complex suturing tasks. METHODS: Participants recruited for this study were novices (no laparoscopic experience), target group for this training (surgical/gynaecologic/urologic residents, > 10 basic and < 20 advanced laparoscopic procedures) and experts (> 20 advanced laparoscopic procedures). Each participant performed the intracorporeal suturing exercise (Task 1), an upside down needle transfer (Task 2, developed for this study) and an anastomosis needle transfer (Task 3). Following, the participants completed a questionnaire regarding their demographics and opinion on the eoSim in terms of realism, didactic value and usability. Measured outcome parameters were time, distance, percentage of instrument tip off-screen, working area, speed, acceleration and smoothness. RESULTS: In total, 104 participants completed the study, of which 60 novices, 31 residents and 13 experts. Face and content validity results showed a mean positive opinion on realism (3.9 Task 1, 3.6 Task 2 and 3.7 Task 3), didactic value (4.0, 3.4 and 3.7, respectively) and usability (4.2. 3.7 and 4.0, respectively). There were no significant differences in these outcomes between the specified expertise groups. Construct validity results showed significant differences between experts, target group or novices for Task 1 in terms of time (means 339, 607 and 1224 s, respectively, p < 0.001) and distance (means 8.1, 15.6 and 21.7 m, respectively, p < 0.001). Task 2 showed significant differences between groups regarding time (p < 0.001), distance (p 0.003), off-screen (p < 0.001) and working area (p < 0.001). Task 3 showed significant differences between groups, after subanalyses, on total number of stitches (p < 0.001), time per stitch (p < 0.001) and distance per stitch (p < 0.001). CONCLUSIONS: The results of this study indicate that the eoSim is a potential meaningful and valuable simulator in the training of suturing tasks.


Subject(s)
Clinical Competence , Computer Simulation , Education, Medical, Graduate/methods , Gynecologic Surgical Procedures/education , Laparoscopy/education , Sutures , Urologic Surgical Procedures/education , Adult , Female , Humans , Netherlands , Reproducibility of Results , Surveys and Questionnaires
5.
Int J Surg ; 53: 137-142, 2018 May.
Article in English | MEDLINE | ID: mdl-29581045

ABSTRACT

INTRODUCTION: There has been a wide uptake in the use of Minimal Invasive Surgery (MIS) globally across different surgical specialties. Whilst evidence exists for a structured training curriculum for basic laparoscopic surgery, there is little agreement on a complete framework for an advanced MIS training curriculum, defining the essential elements of the curriculum including the optimal assessment methods. The aim of this study is to obtain a consensus on the essential elements of a training curriculum for advanced MIS. MATERIALS AND METHODS: A Delphi study was carried out involving 57 international experts in advanced MIS across different surgical specialties. A three round survey was conducted to reach consensus on the essential domains of a curriculum. This included defining the learners, trainers and training centres; curriculum content and competency based assessment. RESULTS: Unanimous agreement was reached for the completion of basic laparoscopic training before entry into advanced training. A trainer should have reached competency in advanced MIS and attended a 'Train the trainer' course. The curriculum should be delivered as modular training, including a multi-modal approach with a structured clinical proctorship programme. Formative assessment was considered as an integral part of learning and should be performed using objective work based assessment tools such as global assessment scale (GAS) forms. Accreditation in advanced MIS can be achieved by objective assessment of technical performance of unedited videos in addition to key clinical performance outcomes. CONCLUSION: A consensus on the framework of an advanced MIS training curriculum has been achieved defining the essential elements of entry criteria, selection of trainers and training units and curriculum content. Multimodal learning, clinical proctorship programme and competency based assessment are integral parts of the curriculum.


Subject(s)
Curriculum , Internship and Residency , Laparoscopy/education , Specialties, Surgical/education , Clinical Competence , Consensus , Delphi Technique , Humans , Surveys and Questionnaires
6.
Surg Endosc ; 32(6): 2994-2999, 2018 06.
Article in English | MEDLINE | ID: mdl-29340824

ABSTRACT

BACKGROUND: The use of motion tracking has been proved to provide an objective assessment in surgical skills training. Current systems, however, require the use of additional equipment or specialised laparoscopic instruments and cameras to extract the data. The aim of this study was to determine the possibility of using a software-based solution to extract the data. METHODS: 6 expert and 23 novice participants performed a basic laparoscopic cholecystectomy procedure in the operating room. The recorded videos were analysed using Kinovea 0.8.15 and the following parameters calculated the path length, average instrument movement and number of sudden or extreme movements. RESULTS: The analysed data showed that experts had significantly shorter path length (median 127 cm vs. 187 cm, p = 0.01), smaller average movements (median 0.40 cm vs. 0.32 cm, p = 0.002) and fewer sudden movements (median 14.00 vs. 21.61, p = 0.001) than their novice counterparts. CONCLUSION: The use of software-based video motion tracking of laparoscopic cholecystectomy is a simple and viable method enabling objective assessment of surgical performance. It provides clear discrimination between expert and novice performance.


Subject(s)
Cholecystectomy, Laparoscopic/education , Clinical Competence , Software , Video Recording , Humans
7.
J Surg Educ ; 75(2): 527-533, 2018.
Article in English | MEDLINE | ID: mdl-28822819

ABSTRACT

OBJECTIVE: To establish whether a systematized approach to self-assessment in a laparoscopic surgical skills course improves accordance between expert- and self-assessment. DESIGN: A systematic training course in self-assessment using Competency Assessment Tool was introduced into the normal course of evaluation within a Laparoscopic Surgical Skills training course for the test group (n = 30). Differences between these and a control group (n = 30) who did not receive the additional training were assessed. SETTING: Catharina Hospital, Eindhoven, The Netherlands (n = 27), and GSL Medical College, Rajahmundry, India (n = 33). PARTICIPANTS: Sixty postgraduate year 2 and 3 surgical residents who attended the 2-day Laparoscopic Surgical Skills grade 1 level 1 curriculum were invited to participate. RESULTS: The test group (n = 30) showed better accordance between expert- and self-assessment (difference of 1.5, standard deviation [SD] = 0.2 versus 3.83, SD = 0.6, p = 0.009) as well as half the number (7 versus 14) of cases of overreporting. Furthermore, the test group also showed higher overall mean performance (mean = 38.1, SD = 0.7 versus mean = 31.8, SD = 1.0, p < 0.001) than the control group (n = 30). The systematic approach to self-assessment can be viewed as responsible for this and can be seen as "reflection-before-practice" within the framework of reflective practice as defined by Donald Schon. CONCLUSION: Our results suggest that "reflection-before-practice" in implementing self-assessment is an important step in the development of surgical skills, yielding both better understanding of one's strengths and weaknesses and also improving overall performance.


Subject(s)
Cholecystectomy, Laparoscopic/education , Clinical Competence , Education, Medical, Graduate/methods , Internship and Residency/methods , Laparoscopy/education , Self-Assessment , Adult , Curriculum , Female , Humans , India , Male , Netherlands , Task Performance and Analysis
8.
Surg Endosc ; 31(6): 2451-2456, 2017 06.
Article in English | MEDLINE | ID: mdl-27655377

ABSTRACT

BACKGROUND: The concept of self-assessment has been widely acclaimed for its role in the professional development cycle and self-regulation. In the field of medical education, self-assessment has been most used to evaluate the cognitive knowledge of students. The complexity of training and evaluation in laparoscopic surgery has previously acted as a barrier in determining the benefits self-assessment has to offer in comparison with other fields of medical education. METHODS: Thirty-five surgical residents who attended the 2-day Laparoscopic Surgical Skills Grade 1 Level 1 curriculum were invited to participate from The Netherlands, India and Romania. The competency assessment tool (CAT) for laparoscopic cholecystectomy was used for self- and expert-assessment and the resulting distributions assessed. RESULTS: A comparison between the expert- and self-assessed aggregates of scores from the CAT agreed with previous studies. Uniquely to this study, the aggregates of individual sub-categories-'use of instruments'; 'tissue handling'; and errors 'within the component tasks' and the 'end product' from both self- and expert-assessments-were investigated. There was strong positive correlation (r s > 0.5; p < 0.001) between the expert- and self-assessment in all categories with only the 'tissue handling' having a weaker correlation (r s = 0.3; p = 0.04). The distribution of the mean of the differences between self-assessment and expert-assessment suggested no significant difference between the scores of experts and the residents in all categories except the 'end product' evaluation where the difference was significant (W = 119, p = 0.03). CONCLUSION: Self-assessment using the CAT form gives results that are consistently not different from expert-assessment when assessing one's proficiency in surgical skills. Areas where there was less agreement could be explained by variations in the level of training and understanding of the assessment criteria.


Subject(s)
Cholecystectomy, Laparoscopic/education , Clinical Competence , Internship and Residency , Self-Assessment , Female , Humans , India , Male , Netherlands , Romania
9.
Surg Endosc ; 31(6): 2607-2615, 2017 06.
Article in English | MEDLINE | ID: mdl-27734203

ABSTRACT

BACKGROUND: Laparoscopic surgery for colon cancer is associated with improved recovery and similar cancer outcomes at 3 and 5 years in comparison with open surgery. However, long-term survival rates have rarely been reported. Here, we present survival and recurrence rates of the Dutch patients included in the COlon cancer Laparoscopic or Open Resection (COLOR) trial at 10-year follow-up. METHODS: Between March 1997 and March 2003, patients with non-metastatic colon cancer were recruited by 29 hospitals in eight countries and randomised to either laparoscopic or open surgery. Main inclusion criterion for the COLOR trial was solitary adenocarcinoma of the left or right colon. The primary outcome was disease-free survival at 3 years, and secondary outcomes included overall survival and recurrence. The 10-year follow-up data of all Dutch patients were collected. Analysis was by intention-to-treat. The trial was registered at ClinicalTrials.gov (NCT00387842). RESULTS: In total, 1248 patients were randomised, of which 329 were Dutch. Fifty-eight Dutch patients were excluded and 15 were lost to follow-up, leaving 256 patients for 10-year analysis. Median follow-up was 112 months. Disease-free survival rates were 45.2 % in the laparoscopic group and 43.2 % in the open group (difference 2.0 %; 95 % confidence interval (CI) -10.3 to 14.3; p = 0.96). Overall survival rates were 48.4 and 46.7 %, respectively (difference 1.7 %; 95 % CI -10.6 to 14.0; p = 0.83). Stage-specific analysis revealed similar survival rates for both groups. Sixty-two patients were diagnosed with recurrent disease, accounting for 29.4 % in the laparoscopic group and 28.2 % in the open group (difference 1.2 %; 95 % CI -11.1 to 13.5; p = 0.73). Seven patients had port- or wound-site recurrences (laparoscopic n = 3 vs. open n = 4). CONCLUSIONS: Laparoscopic surgery for non-metastatic colon cancer is associated with similar rates of disease-free survival, overall survival and recurrences as open surgery at 10-year follow-up.


Subject(s)
Adenocarcinoma/surgery , Colonic Neoplasms/surgery , Neoplasm Recurrence, Local/surgery , Adenocarcinoma/mortality , Aged , Aged, 80 and over , Colonic Neoplasms/mortality , Disease-Free Survival , Ethnicity , Female , Humans , Laparoscopy , Male , Middle Aged , Neoplasm Recurrence, Local/mortality , Netherlands , Survival Rate
10.
Surg Technol Int ; 28: 111-6, 2016 Apr.
Article in English | MEDLINE | ID: mdl-27175810

ABSTRACT

BACKGROUND: The sleeve gastrectomy is being performed increasingly as a primary procedure for the treatment of morbid obesity. A minimally invasive approach is currently applied to the procedure. The two major steps are dissection and stapling. For dissection, several tools have been developed. The goal of this study was to compare the efficiency and the ergonomics of two ultrasonic devices during the sleeve gastrectomy. MATERIALS AND METHODS: Thirty patients were randomised for the use of a cordless Sonicision™ (Covidien, Mansfield, MA) or a cord-containing HARMONIC ACE®+ (Ethicon Endo-Surgery Inc., Cincinnati, OH) during dissection. Both devices were assessed for objective and subjective measures. RESULTS: There was no significant difference in duration of the procedures. The assembly and installation time of the Sonicision™ were significantly shorter; however, the dismantle time was not. No difference in plume formation or dissection failures was found between the devices. Scrub nurses scored the Sonicision™ significantly clearer and easier in use and more reliable. The surgeons, however, did not find one of the devices easier in use, more reliable or precise, but they did report better manoeuvrability of the Sonicision™. CONCLUSION: In comparison to the wired HARMONIC ACE®+, during sleeve gastrectomy, the cordless Sonicision™ was considered easier to use, faster during assembling and installation, and more reliable with better manoeuvrability. Surgeons scored both devices equally effective. Both ultrasonic devices can be used easily and safely for a sleeve gastrectomy.


Subject(s)
Dissection/instrumentation , Electric Power Supplies , Gastrectomy/instrumentation , Minimally Invasive Surgical Procedures/instrumentation , Ultrasonic Surgical Procedures/instrumentation , Adult , Attitude of Health Personnel , Equipment Design , Equipment Failure Analysis , Ergonomics/instrumentation , Female , Humans , Male , Operative Time , Treatment Outcome
11.
Surg Technol Int ; 27: 123-8, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26680415

ABSTRACT

The sleeve gastrectomy has been accepted as a primary bariatric procedure. One of the most feared complications is staple line leakage. It is important to use the right staple sizes to minimize the risk of leak. Knowledge of gastric thickness is important. The goal of this study was to measure the thickness of the gastric wall after elimination of the gastric folds in the mucosa. An electronic thickness gauge was developed that measured the anterior and posterior wall of the fresh stomach specimen together at 5 points at a pressure based on the finger pressure necessary to flatten the gastric folds. Thirty-three fresh specimens were measured. The mean compression pressure was 714 grams, and no difference was found between the 5 measure points. There was a significant difference in stomach wall thickness. The gastric antrum was more than 1 mm thicker than the fundus. No difference was found between BMI groups <40 Kg/m2, 40-50 Kg/m2, or >50 Kg/m2. No bleeding occurred, leakage occurred in 1 case. There is a significant difference in thickness of the stomach wall between the gastric fundus and the antrum. A pressure 2.5 times lower than applied in prior studies was necessary to achieve full tissue compression. Choosing thinner staple sizes for the gastric fundus might be the optimal technique for compression. However, there are several additional factors that influence the risk of staple line leaks.


Subject(s)
Gastrectomy/instrumentation , Gastrectomy/methods , Stomach/physiology , Adult , Equipment Design , Female , Humans , Male , Middle Aged , Postoperative Complications , Prospective Studies
12.
Surg Technol Int ; 24: 19-25, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24526423

ABSTRACT

In recent years, many efforts have been made to reduce the trauma of surgical access further by the use of single-incision laparoscopic surgery (SILS). The Ergo-Lap (ergonomic laparoscopic) simulator was taken to the 20th International Congress of the European Association for Endoscopic Surgery (EAES) in 2012 in Brussels, Belgium. During the congress, the simulator was assessed by 13 general surgeons with different SILS experience using a standardized questionnaire to determine the usability of the Ergo-Lap simulator training for basic SILS skills. Eleven of the 13 participants rated the simulator as an attractive simulator (attractive here means arousing interest of the trainees). For the aspects of training in an ergonomic way, 12 of 13 participants rated it as good to excellent because the work space and task panel location can be adjusted according to the length of instruments. Also, 92% (12 of 13) thought the Ergo-Lap simulator was useful for practicing basic SPLS skills. And 85% (11 of 13) thought it was very easy to use. For SILS skills training, this in~xpensive and portable Ergo-Lap simulator offers a feasible training opportunity to help trainees practice their SILS skills under ergonomic conditions.


Subject(s)
Ergonomics/instrumentation , Laparoscopy/education , Laparoscopy/instrumentation , Surgeons/education , Surgeons/statistics & numerical data , Adult , Computer Simulation , Humans , Male , Middle Aged
13.
J Surg Educ ; 71(1): 65-72, 2014.
Article in English | MEDLINE | ID: mdl-24411426

ABSTRACT

OBJECTIVE: Laparoscopic skills can be improved effectively through laparoscopic simulation. The purpose of this study was to verify the face and content validity of a new portable Ergonomic Laparoscopic Skills simulator (Ergo-Lap simulator) and assess the construct validity of the Ergo-Lap simulator in 4 basic skills tasks. DESIGN: Four tasks were evaluated: 2 different translocation exercises (a basic bimanual exercise and a challenging single-handed exercise), an exercise involving tissue manipulation under tension, and a needle-handling exercise. Task performance was analyzed according to speed and accuracy. The participants rated the usability and didactic value of each task and the Ergo-Lap simulator along a 5-point Likert scale. SETTING: Institutional academic medical center with its affiliated general surgery residency. PARTICIPANTS: Forty-six participants were allotted into 2 groups: a Novice group (n = 26, <10 clinical laparoscopic procedures) and an Experienced group (n = 20, >50 clinical laparoscopic procedures). RESULTS: The Experienced group completed all tasks in less time than the Novice group did (p < 0.001, Mann-Whitney U test). The Experienced group also completed tasks 1, 2, and 4 with fewer errors than the Novice group did (p < 0.05). Of the Novice participants, 96% considered that the present Ergo-Lap simulator could encourage more frequent practice of laparoscopic skills. In addition, 92% would like to purchase this simulator. All of the experienced participants confirmed that the Ergo-Lap simulator was easy to use and useful for practicing basic laparoscopic skills in an ergonomic manner. Most (95%) of these respondents would recommend this simulator to other surgical trainees. CONCLUSIONS: This Ergo-Lap simulator with multiple tasks was rated as a useful training tool that can distinguish between various levels of laparoscopic expertise. The Ergo-Lap simulator is also an inexpensive alternative, which surgical trainees could use to update their skills in the skills laboratory, at home, or in the office.


Subject(s)
Ergonomics , Laparoscopy/education , Teaching Materials , Humans , Reproducibility of Results
14.
Surg Endosc ; 28(5): 1545-54, 2014 May.
Article in English | MEDLINE | ID: mdl-24399519

ABSTRACT

BACKGROUND: Minimal access surgery and, lately, single-incision laparoscopic procedures are challenging and demanding with regard to the skills of the surgeon performing the procedures. This article presents the results of an investigation of the performance and attention focus of 21 medical interns and surgical residents training in an immersive context. That is, training 'in situation', representing more realistically the demands imposed on the surgeons during minimal access surgery. METHODS: Twenty-one medical interns and surgical residents participated in simulation trainings in an integrated operating room for laparoscopic surgery. Various physiological measures of body heat expenditure were gathered as indicators of mental strain and attention focus. RESULTS: The results of the Mann-Whitney test indicated that participants with a poor performance in the two laparoscopic cholecystectomy cases had a significantly (U = 3, p = 0.038) higher heat flux at the start of the procedure (mean 107.08, standard deviation [SD] 24.34) than those who excelled in the two cases (mean 62.64, SD 23.41). Also, the average frontal head temperature of the participants who failed at the task was significantly lower (mean 33.27, SD 0.52) than those who performed well (mean 33.92, SD 0.27). CONCLUSIONS: Surgeons cannot operate in a bubble; thus, they should not be trained in one. Combining heat flux and frontal head temperature could be a good measure of deep involvement and attentional focus during performance of simulated surgical tasks.


Subject(s)
Attention/physiology , Cognition/physiology , Education, Medical, Continuing/methods , Hot Temperature/adverse effects , Internship and Residency , Laparoscopy/education , Operating Rooms , Adult , Body Temperature/physiology , Clinical Competence , Computer Simulation , Female , Humans , Laparoscopy/psychology , Male , Workload , Young Adult
15.
Surg Innov ; 21(3): 297-302, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24172167

ABSTRACT

BACKGROUND: Surgery for locally advanced and recurrent rectal carcinoma can be associated with major blood loss. OBJECTIVE: We developed a promising technique using a hemostatic balloon to stop uncontrollable bleeding. DESIGN: Models were developed using pelvic magnetic resonance imaging scans, and these models were tested in a cadaveric study. Eventually a model was tested in a clinical setting. The Hemostatic Balloon Device was placed in patients in whom during surgery uncontrollable bleeding from the venous presacral plexus occurred. SETTINGS: A tertiary referral hospital for locally advanced and recurrent rectal cancer. PATIENTS: Patients receiving multimodality treatment for primary or recurrent locally advanced rectal carcinomas. MAIN OUTCOME MEASURES: First the developed prototypes were tested in a cadaveric study where the developing pressure on the pelvic wall was measured. Second, the Hemostatic Balloon Device was placed in patients in whom during surgery uncontrollable bleeding from the venous presacral plexus occurred. RESULTS: The balloon was used in 9 patients. Median volume of blood loss was 7500 mL. In 8 patients treatment with the hemostatic balloon was successful. In 1 patient the balloon was dislocated cranially and the pelvis was packed with surgical gauzes. LIMITATIONS: These first results are promising but further research is needed to evaluate how effective the balloon is in controlling massive bleeding during rectal cancer surgery. Future perspectives include a possibly thinner silicon rubber that can be stretched more easily with a lower inflated volume. DISCUSSION: The hemostatic balloon is a new and promising technique for accomplishing hemostasis with controllable pressure on the pelvic cavity wall and can be removed without the need for a second laparotomy.


Subject(s)
Hemostasis, Surgical/instrumentation , Hemostasis, Surgical/methods , Rectal Neoplasms/surgery , Aged , Aged, 80 and over , Blood Loss, Surgical/prevention & control , Cohort Studies , Equipment Design , Female , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Organ Sparing Treatments
16.
Minim Invasive Ther Allied Technol ; 22(6): 337-45, 2013 Dec.
Article in English | MEDLINE | ID: mdl-23992382

ABSTRACT

OBJECTIVE: The cost of laparoscopic simulators restricts the wide use of simulation for training of basic psychomotor skills. This paper describes the scientifically-based development of an inexpensive and portable Ergonomic Laparoscopic Skills (Ergo-Lap) simulator with multiple tasks. MATERIAL AND METHODS: The design of this Ergo-Lap simulator and related training task panel was based on scientific research regarding the representative skills and the ergonomic guidelines for laparoscopic surgery. A user-centred design approach was followed. Fifty-three surgical participants with variable laparoscopic experience (14 medical students, 27 surgeons in training, and 12 experienced laparoscopic surgeons) performed several tasks on the prototype and gave their feedback by filling out a 5-point scale Likert scale questionnaire. RESULTS: The results of the usability evaluation showed that the participants regarded the Ergo-Lap simulator as a useful device to practice the basic and advanced skills effectively. Forty-three of the 53 participants indicated they would like to purchase this simulator since it is easy to use and challenges their laparoscopic skills. CONCLUSIONS: For laparoscopic skills training, this inexpensive Ergo-Lap simulator with diverse task choices offers a simple training opportunity for trainees who want to practice laparoscopic skills at home or at the office.


Subject(s)
Clinical Competence , Computer Simulation , Ergonomics/methods , Laparoscopy/education , Computer Simulation/economics , Education, Medical, Continuing/economics , Education, Medical, Continuing/methods , Equipment Design , Ergonomics/economics , Humans , Practice Guidelines as Topic , Psychomotor Performance , Students, Medical , Surveys and Questionnaires , User-Computer Interface
17.
Wideochir Inne Tech Maloinwazyjne ; 7(3): 188-92, 2012 Aug.
Article in English | MEDLINE | ID: mdl-23256024

ABSTRACT

INTRODUCTION: New training models are needed to maintain safety and quality of surgical performance. A simulated setting using virtual reality, synthetic, and/or organic models should precede traditional supervised training in the operating room. AIM: The aim of the paper is to describe the Laparoscopic Surgical Skills (LSS) programme and to provide information about preliminary evaluation of Grade I Level 1 courses, including overall quality, applicability of the course content in practice and the balance between theory and hands-on training modules, by participating trainees. MATERIAL AND METHODS: During 5 accredited LSS Grade I Level 1 courses held in Eindhoven (the Netherlands), Kosice (Slovak Republic), and Lisbon (Portugal) between April 2011 and January 2012, demographic data and pre-course surgical experience in laparoscopic surgery of the participants were recorded. The final course evaluation form was completed by each participant after the course (anonymous) to evaluate course progress, course materials, assessment, staff, location and overall impression of the course on a 1-10 scale to obtain feedback information. RESULTS: Forty-seven surgeons of 5 different nationalities were enrolled in an LSS Grade I Level 1 programme. Most participants were first or second year residents (n = 25), but also already established surgeons took part (n = 6). The mean age of the participants was 31.2 years (SD = 2.86), the male/female ratio was 32/15, and previous experience with laparoscopic surgery was limited. Overall impression of the course was rated with 8.7 points (SD = 0.78). The applicability of the course content in practice and the balance between theory and hands-on training were also rated very well - mean 8.8 (SD = 1.01) and 8.1 points (SD = 0.80) respectively. CONCLUSIONS: Laparoscopic Surgical Skills Grade I Level 1 courses are evaluated as well balanced, with content applicable in clinical practice, meeting the expectations of individual participants. International interest in the programme suggests that LSS might become the future European standard in surgical education in laparoscopic surgery. Further conclusions concerning success of the programme may be drawn after the completion of clinical assessment of enrolled participants.

18.
Surg Endosc ; 26(8): 2172-8, 2012 Aug.
Article in English | MEDLINE | ID: mdl-22350237

ABSTRACT

INTRODUCTION: Even though literature provides compelling evidence of the value of simulators for training of basic laparoscopic skills, the best way to incorporate them into a surgical curriculum is unclear. This study compares the training outcome of single modality training with multimodality training of basic laparoscopic skills. METHODS: Thirty-six medical students without laparoscopic experience performed six training sessions of 45 min each, one per day, in which four different basic tasks were trained. Participants in the single-modality group (S) (n = 18) practiced solely on a virtual reality (VR) simulator. Participants in the multimodality group (M) (n = 18) practiced on the same VR simulator (2x), a box trainer (2x), and an augmented reality simulator (2x). All participants performed a pre-test and post-test on the VR simulator (the four basic tasks + one additional basic task). Halfway through the training protocol, both groups performed a salpingectomy on the VR simulator as interim test. RESULTS: Both groups improved their performance significantly (Wilcoxon signed-rank, P < 0.05). The performances of group S and group M in the additional basic task and the salpingectomy did not differ significantly (Mann-Whitney U test, P > 0.05). Group S performed the four basic tasks in the post-test on the VR faster than group M (P ≤ 0.05), which can be explained by the fact that they were much more familiar with these tasks. CONCLUSIONS: Training of basic laparoscopic tasks on single or multiple modalities does not result in different training outcome. Both training methods seem appropriate for the attainment of basic laparoscopic skills in future curricula.


Subject(s)
Clinical Competence/standards , Computer Simulation , General Surgery/education , Internship and Residency , Laparoscopy/education , User-Computer Interface , Humans , Psychomotor Performance , Time Factors
19.
World J Surg ; 36(5): 939-44, 2012 May.
Article in English | MEDLINE | ID: mdl-22354488

ABSTRACT

INTRODUCTION: During the past years, there has been increasing interest in simulation-based training of technical skills especially in laparoscopy. The purpose of this study was to compare the performances of novice and experienced laparoscopic surgeons on a LESS simulator. METHODS: The study recruited 20 surgeons classified into two groups: group NS consisted of ten residents without any laparoscopic experience, and group ES consisted of ten surgeons with experience in conventional laparoscopy (performed >90 laparoscopic cholecystectomies) but without any experience in LESS surgery. Both groups completed a mini-trainee course that included four repetitions of a standardized task of circle pattern cutting (CIRCLE). Time, path length, and economy of movement were measured and compared. RESULTS: Group ES presented significantly better time scores than group NS in all four repetitions. Economy of movement did not differ significantly between the two groups, whereas path length was shorter for beginners at the forth effort. Moreover, group ES failed to improve path length and economy of movement scores, whereas group NS improved their performance significantly in these parameters. CONCLUSIONS: It seems that previous laparoscopic experience in conventional laparoscopy may not necessarily be an advantage in all parameters of LESS surgery and the learning process can be longer than expected even for experienced surgeons.


Subject(s)
Clinical Competence , General Surgery/education , Internship and Residency , Laparoscopy/education , Adult , Computer Simulation , Female , Humans , Laparoscopy/methods , Male , Manikins
20.
Appl Ergon ; 43(3): 548-53, 2012 May.
Article in English | MEDLINE | ID: mdl-21893312

ABSTRACT

This paper evaluates the effect of ergonomic factors on task performance and trainee posture during laparoscopic surgery training. Twenty subjects without laparoscopic experience were allotted into 2 groups. Group 1 was trained under the optimal ergonomic simulation setting according to current ergonomic guidelines (Condition A). Group 2 was trained under non-optimal ergonomic simulation setting that can often be observed during training in a skills lab (Condition B). Posture analysis showed that the subjects held a much more neutral posture under Condition A than under Condition B (p<0.001). The subjects had less joint excursion and experienced less discomfort in their neck, shoulders, and arms under Condition A. Significant difference in task performance between Conditions A and B (p<0.05) was found. This study shows that the optimal ergonomic simulation setting leads to better task performance. In addition, no significant differences of task performance, for Groups 1 and 2 using the same test setting were found. However, better performance was observed for Group 1. It can be concluded that the optimal and non-optimal training setting have different learning effects on trainees' skill learning.


Subject(s)
General Surgery/education , Laparoscopy/education , Adult , Ergonomics , Female , Humans , Male , Muscle Fatigue , Posture , Task Performance and Analysis , Upper Extremity/physiology , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...