Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Ann Surg ; 273(5): 997-1003, 2021 05 01.
Article in English | MEDLINE | ID: mdl-30973389

ABSTRACT

OBJECTIVE: The objective of this study was to evaluate the outcome of endovascular aortic arch repair for chronic dissection with a custom-made branched endograft. BACKGROUND: Acute type A aortic dissections are often treated with prosthetic replacement of the ascending aorta. During follow-up, repair of an aneurysmal evolution of the false lumen distal to the ascending prosthesis can be a challenge both for the surgeon and the patient. METHODS: We conducted a multicenter, retrospective study of consecutive patients from 14 vascular units treated with a custom-made, inner-branched device (Cook Medical, Bloomington, IN) for chronic aortic arch dissection. Rates of in-hospital mortality and stroke, technical success, early and late complications, reinterventions, and mortality during follow-up were evaluated. RESULTS: Seventy consecutive patients were treated between 2011 and 2018. All patients were considered unfit for conventional surgery. In-hospital combined mortality and stroke rate was 4% (n = 3), including 1 minor stroke, 1 major stroke causing death, and 1 death following multiorgan failure. Technical success rate was 94.3%. Twelve (17.1%) patients required early reinterventions: 8 for vascular access complication, 2 for endoleak correction, and 2 for pericardial effusion drainage. Median follow-up was 301 (138-642) days. During follow-up, 20 (29%) patients underwent secondary interventions: 9 endoleak corrections, 1 open repair for prosthetic kink, and 10 distal extensions of the graft to the thoracic or thoracoabdominal aorta. Eight patients (11%) died during follow-up because of nonaortic-related cause in 7 cases. CONCLUSIONS: Endovascular treatment of aortic arch chronic dissections with a branched endograft is associated with low mortality and stroke rates but has a high reintervention rate. Further follow-up is required to confirm the benefits of this novel approach.


Subject(s)
Aorta, Thoracic/surgery , Aortic Aneurysm, Thoracic/surgery , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation/methods , Endovascular Procedures/methods , Aortic Dissection/diagnosis , Aortic Dissection/mortality , Aorta, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/diagnosis , Aortic Aneurysm, Thoracic/mortality , Chronic Disease , Computed Tomography Angiography , Female , Follow-Up Studies , Global Health , Hospital Mortality/trends , Humans , Male , Middle Aged , Prosthesis Design , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...