Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
RSC Adv ; 12(15): 9058-9068, 2022 Mar 21.
Article in English | MEDLINE | ID: mdl-35424891

ABSTRACT

In the current paper, we produce a new metal-organic framework (MOF) based on Zr metal, [Zr-UiO-66-PDC-SO3H]FeCl4, via an anion exchange method, which is fully characterized by FT-IR, SEM with elemental mapping and EDX, FE-SEM and TEM. Furthermore, the use of [Zr-UiO-66-PDC-SO3H]FeCl4 as a porous catalyst was examined for the one-pot synthesis of novel dihydrobenzo[g]pyrimido[4,5-b]quinoline derivatives by reaction of 6-amino-1,3-dimethylpyrimidine-2,4(1H,3H)-dione, 2-hydroxynaphthalene-1,4-dione and various aldehydes at 100 °C with good to excellent yields.

2.
Emerg (Tehran) ; 6(1): e29, 2018.
Article in English | MEDLINE | ID: mdl-30009231

ABSTRACT

Traumatic pulmonary pseudocyst is a rare complication of chest trauma that has been poorly documented and usually resolves without specific treatment. Here, we present a case of pulmonary pseudocyst in a child with chest trauma without obvious symptoms. It is important to consider this diagnosis in patients with chest trauma to avoid unnecessary invasive procedures.

3.
Tanaffos ; 14(4): 252-6, 2015.
Article in English | MEDLINE | ID: mdl-27114727

ABSTRACT

BACKGROUND: Tracheal stenosis, which has received more emphasis recently, is a common post intubation complication and may develop due to different reasons. One important reason is the endotracheal tube cuff pressure. Therefore, this study sought to examine the accuracy of diagnostic test for palpation and minimal occlusive volume techniques to measure the endotracheal tube cuff pressure. MATERIALS AND METHODS: In this cross sectional study, the accuracy of diagnostic tests for palpation and minimal occlusive volume techniques to measure the endotracheal tube cuff pressure was assessed in 101 patients aged over 18 years who had undergone open heart surgery and post-surgical mechanical ventilation in the ICU. RESULTS: In the palpation technique, the cuff pressure of 27 patients (26.7%) was reported to be out of the permissible range and for the rest of them (74 patients, 73.3%) it was within the permissible range. Then, the cuff pressure was checked by the standard method using a manometer and after comparing the results it was found that the cuff pressure of 92 patients (91.1%) was not in the permissible range and only nine patients (8.9%) had a cuff pressure within the permissible range (20-30 cm H2O). In minimal occlusive volume method compared with the standard method, 22 patients (21.7%) had cuff pressure within the permissible range of 20-30 cm H2O, and 79 of them (78.2%) had cuff pressure out of the permissible range and higher than the upper limit. CONCLUSION: This study recommends that the best way to measure the endotracheal tube cuff pressure is to use a cuff manometer, and when it is not available, the minimal occlusive volume would be a better alternative compared to the palpation technique to keep the cuff pressure within a proper range to avoid tracheotomy complications such as tracheal stenosis.

SELECTION OF CITATIONS
SEARCH DETAIL
...