Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 29
Filter
Add more filters










Publication year range
1.
Acta Cir Bras ; 27(10): 671-80, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23033127

ABSTRACT

PURPOSE: To evaluate, in large abdominal wall defects surgically shaped in rats, if a synthetic polypropylene nonwoven prosthesis could be used as a therapeutic option to conventional polypropylene mesh. METHODS: Twenty four (24) Wistar rats were enrolled into three groups. Group 1 (Simulation group) with an abdominal wall defect of 3 X 3 left untreated and Groups 2 and 3, respectively treated with a conventional polypropylene mesh and a polypropylene nonwoven (NWV) prosthesis to cover the breach. At the 45th postoperatively day, adhesion (area and strength) and vascularization of Groups 2 and 3 were evaluated. The histological preparations with Hematoxylin-Eosin, Tricromium of Masson, Pricrosirius red and polarization with birefringence, and also the structural analysis of the prostheses carried on by Thermogravimetry and Differential Scanning Calorimetry were also assessed. RESULTS: There were no significant differences between the Groups 2 and 3. CONCLUSION: In rats, the polypropylene nonwoven prosthesis showed to be safe and has to be considered as an alternative to conventional mesh manufactured by weaving in the treatment of great defects of the abdominal wall.


Subject(s)
Abdominal Wall/surgery , Biocompatible Materials/therapeutic use , Hernia, Ventral/surgery , Polypropylenes/therapeutic use , Prostheses and Implants , Surgical Mesh , Animals , Disease Models, Animal , Female , Materials Testing , Prosthesis Implantation/methods , Rats , Rats, Wistar , Tissue Adhesions , Treatment Outcome
2.
Acta cir. bras ; 27(10): 671-680, Oct. 2012. ilus, tab
Article in English | LILACS | ID: lil-650555

ABSTRACT

PURPOSE: To evaluate, in large abdominal wall defects surgically shaped in rats, if a synthetic polypropylene nonwoven prosthesis could be used as a therapeutic option to conventional polypropylene mesh. METHODS: Twenty four (24) Wistar rats were enrolled into three groups. Group 1 (Simulation group) with an abdominal wall defect of 3 X 3 left untreated and Groups 2 and 3, respectively treated with a conventional polypropylene mesh and a polypropylene nonwoven (NWV) prosthesis to cover the breach. At the 45th postoperatively day, adhesion (area and strength) and vascularization of Groups 2 and 3 were evaluated. The histological preparations with Hematoxylin-Eosin, Tricromium of Masson, Pricrosirius red and polarization with birefringence, and also the structural analysis of the prostheses carried on by Thermogravimetry and Differential Scanning Calorimetry were also assessed. RESULTS: There were no significant differences between the Groups 2 and 3. CONCLUSION: In rats, the polypropylene nonwoven prosthesis showed to be safe and has to be considered as an alternative to conventional mesh manufactured by weaving in the treatment of great defects of the abdominal wall.


OBJETIVO: Avaliar, em grandes defeitos da parede abdominal produzidos cirurgicamente em ratos, se uma prótese sintética de polipropileno sem tecelagem poderia ser utilizada como alternativa terapêutica às telas convencionais de polipropileno. MÉTODOS: Vinte e quatro ratos foram distribuídos em três grupos numericamente iguais. Grupo 1 (Simulação), no qual um defeito de 3 x 3 cm foi constituído na parede abdominal sem tratamento. Uma tela convencional de polipropileno e uma tela de polipropileno sem tecelagem foram colocadas para cobrir o defeito, nos grupos 2 e 3 , respectivamente. No 45º dia de pós-operatório foram avaliadas a área e a força das aderências, além da vascularização. Também foram analisados os preparados histológicos com Hematoxilina-eosina, Tricrômio de Masson e Picrosirius com polarização e birrefringência, além de efetuada análise estrutural da prótese mediante Termogavimetria e Colorimetria Exploratória Diferencial. RESULTADOS: Não houve diferença significante entre os grupos 2 e 3. CONCLUSÃO: Em ratos, a tela de polipropileno sem tecelagem mostrou ser segura e deve ser considerada como uma alternativa à tela convencional manufaturada por tecelagem, no tratamento dos grandes defeitos da parede abdominal.


Subject(s)
Animals , Female , Rats , Abdominal Wall/surgery , Biocompatible Materials/therapeutic use , Hernia, Ventral/surgery , Prostheses and Implants , Polypropylenes/therapeutic use , Surgical Mesh , Disease Models, Animal , Materials Testing , Prosthesis Implantation/methods , Rats, Wistar , Tissue Adhesions , Treatment Outcome
3.
Intensive Care Med ; 38(3): 499-508, 2012 Mar.
Article in English | MEDLINE | ID: mdl-22234736

ABSTRACT

PURPOSE: We hypothesized that: (1) intraabdominal hypertension increases pulmonary inflammatory and fibrogenic responses in acute lung injury (ALI); (2) in the presence of intraabdominal hypertension, higher tidal volume reduces lung damage in extrapulmonary ALI, but not in pulmonary ALI. METHODS: Wistar rats were randomly allocated to receive Escherichia coli lipopolysaccharide intratracheally (pulmonary ALI) or intraperitoneally (extrapulmonary ALI). After 24 h, animals were randomized into subgroups without or with intraabdominal hypertension (15 mmHg) and ventilated with positive end expiratory pressure = 5 cmH(2)O and tidal volume of 6 or 10 ml/kg during 1 h. Lung and chest wall mechanics, arterial blood gases, lung and distal organ histology, and interleukin (IL)-1ß, IL-6, caspase-3 and type III procollagen (PCIII) mRNA expressions in lung tissue were analyzed. RESULTS: With intraabdominal hypertension, (1) chest-wall static elastance increased, and PCIII, IL-1ß, IL-6, and caspase-3 expressions were more pronounced than in animals with normal intraabdominal pressure in both ALI groups; (2) in extrapulmonary ALI, higher tidal volume was associated with decreased atelectasis, and lower IL-6 and caspase-3 expressions; (3) in pulmonary ALI, higher tidal volume led to higher IL-6 expression; and (4) in pulmonary ALI, liver, kidney, and villi cell apoptosis was increased, but not affected by tidal volume. CONCLUSIONS: Intraabdominal hypertension increased inflammation and fibrogenesis in the lung independent of ALI etiology. In extrapulmonary ALI associated with intraabdominal hypertension, higher tidal volume improved lung morphometry with lower inflammation in lung tissue. Conversely, in pulmonary ALI associated with intraabdominal hypertension, higher tidal volume increased IL-6 expression.


Subject(s)
Acute Lung Injury/immunology , Intra-Abdominal Hypertension/immunology , Pulmonary Fibrosis/etiology , Tidal Volume/physiology , Acute Lung Injury/pathology , Analysis of Variance , Animals , Apoptosis/drug effects , Collagen Type III , Cytokines/immunology , Escherichia coli , Infusions, Parenteral , Intra-Abdominal Hypertension/complications , Intubation, Intratracheal , Lipopolysaccharides/administration & dosage , Positive-Pressure Respiration/methods , Random Allocation , Rats , Rats, Wistar
4.
Acta Cir Bras ; 22(3): 229-33, 2007.
Article in English | MEDLINE | ID: mdl-17546297

ABSTRACT

PURPOSE: The difficulty to anesthetize small laboratory animals with vaporizer prompted us to go in search of new materials, and create new techniques. The improved equipment of anesthesia we looked for should be low cost, practical, versatile, and its management serve ethical, teaching, and research purposes. METHODS: The new components of the equipment were: the vaporizer, the unidirectional valve, the glass cylinder filled with water, the flow guidance y-shape tube, the flow regulators, the mask modifications, and another free airway for emergency occurrence. A test was done with 30 Wistar rats, Rattus norvegicus albinus, divided into three groups with 10 rats for each one. Groups 1, 2 and 3 were anesthetized with Ether, Halothane and Sevoflurane respectively, using the new gadget. The anesthetic induction time, the breathing rhythm alteration during an anesthesia pre-established time (10 minutes), and the recovery time were observed. RESULTS: The equipment enabled an easy handling, and fulfilled a larger safeness and stability during the induction and anesthetic management. The test showed it was possible to make use of several anesthetic agents. CONCLUSION: The device is effective, and turns the anesthesia procedure into a very easy practice with low-cost. It should be recommended for experimental surgery, teaching and research.


Subject(s)
Anesthesia, Inhalation/veterinary , Anesthetics, Inhalation/administration & dosage , Anesthesia, Inhalation/instrumentation , Anesthesia, Inhalation/standards , Animals , Animals, Laboratory/surgery , Equipment Design , Rats , Rats, Wistar
5.
Acta cir. bras ; 22(3): 229-233, May-June 2007. tab, ilus
Article in English | LILACS | ID: lil-452206

ABSTRACT

PURPOSE: The difficulty to anesthetize small laboratory animals with vaporizer prompted us to go in search of new materials, and create new techniques. The improved equipment of anesthesia we looked for should be low cost, practical, versatile, and its management serve ethical, teaching, and research purposes. METHODS: The new components of the equipment were: the vaporizer, the unidirectional valve, the glass cylinder filled with water, the flow guidance y-shape tube, the flow regulators, the mask modifications, and another free airway for emergency occurrence. A test was done with 30 Wistar rats, Rattus norvegicus albinus, divided into three groups with 10 rats for each one. Groups 1, 2 and 3 were anesthetized with Ether, Halothane and Sevoflurane respectively, using the new gadget. The anesthetic induction time, the breathing rhythm alteration during an anesthesia pre-established time (10 minutes), and the recovery time were observed. RESULTS: The equipment enabled an easy handling, and fulfilled a larger safeness and stability during the induction and anesthetic management. The test showed it was possible to make use of several anesthetic agents. CONCLUSION: The device is effective, and turns the anesthesia procedure into a very easy practice with low-cost. It should be recommended for experimental surgery, teaching and research.


OBJETIVOS: As dificuldades evidenciadas no uso de vaporizadores para anestesia em animais de pequeno porte motivaram o aperfeiçoamento e a criação de novos componentes técnicos visando a construção de um aparelho de anestesia de baixo custo, prático e versátil no manuseio e que atenda aos preceitos éticos do ensino e da pesquisa. MÉTODOS: Utilizaram-se 30 ratos da linhagem Wistar, Rattus norvegicus albinus, distribuídos em três grupos. Grupo 1,2 e 3 (n=10, cada), compreenderam o uso do novo aparelho aduzido, respectivamente, do Éter; Halotano e Sevoflurano. Foram verificados o tempo de indução anestésica, as alterações do ritmo ventilatório durante o tempo de manutenção anestésica (pré-estabelecido em 10 min) e o tempo de recuperação anestésica. O aparelho foi construído com dispositivos técnicos novos sobressaindo: o vaporizador, a válvula unidirecional na campânula, o cilindro de vidro com água, o tubo direcionador de fluxo em forma de Y, os reguladores de fluxo, as modificações na máscara e a entrada de ar, independente, para situações emergenciais. RESULTADOS: O aparelho permitiu um fácil manuseio e propiciou uma maior segurança e estabilidade na indução e manutenção anestésicas possibilitando, inclusive, a utilização de vários agentes anestésicos. CONCLUSÃO: O aparelho demonstrou ser útil para anestesia em cirurgia experimental, facilitando a realização dos procedimentos de pesquisa e de ensino de forma mais prática, eficiente, segura, e com baixo custo.


Subject(s)
Animals , Rats , Anesthesia, Inhalation/veterinary , Anesthetics, Inhalation/administration & dosage , Anesthesia, Inhalation/instrumentation , Anesthesia, Inhalation/standards , Animals, Laboratory/surgery , Equipment Design , Rats, Wistar
6.
Acta Cir Bras ; 22(1): 57-62, 2007.
Article in English | MEDLINE | ID: mdl-17293952

ABSTRACT

PURPOSE: To test the use of intraluminal protection in colonic anastomosis without intestinal cleansing. The intraluminal liner was fashioned from porcine submucosa preserved in glycerin and then fixed 10 cm anteriorly to the anastomotic site. This technique was compared with the one used in termino-terminal colonic anastomosis without intraluminal protection. METHODS: Twenty-eight dogs were divided into two groups of fourteen animals each. Clinical and histopathological tests were performed on the fourth and twenty-first postoperative days. RESULTS: The morbidity and mortality rates were higher in animals that did not receive the intraluminal liner. Histopathological examinations in animals in which the intraluminal liner was used showed better healing, characterized by milder inflammation and increased amount of collagen. CONCLUSION: It can be concluded that the use of intraluminal protection decreases complication rates in colonic anastomosis and promotes better healing.


Subject(s)
Colon/surgery , Glycerol/therapeutic use , Intestinal Mucosa/transplantation , Anastomosis, Surgical/adverse effects , Anastomosis, Surgical/methods , Anastomosis, Surgical/mortality , Animals , Collagen , Dogs , Female , Inflammation , Models, Animal , Surgical Wound Dehiscence/etiology , Swine , Wound Healing
7.
Acta cir. bras ; 22(1): 57-62, Jan.-Feb. 2007. ilus
Article in English | LILACS | ID: lil-440734

ABSTRACT

PURPOSE: To test the use of intraluminal protection in colonic anastomosis without intestinal cleansing. The intraluminal liner was fashioned from porcine submucosa preserved in glycerin and then fixed 10 cm anteriorly to the anastomotic site. This technique was compared with the one used in termino-terminal colonic anastomosis without intraluminal protection. METHODS: Twenty-eight dogs were divided into two groups of fourteen animals each. Clinical and histopathological tests were performed on the fourth and twenty-first postoperative days. RESULTS: The morbidity and mortality rates were higher in animals that did not receive the intraluminal liner. Histopathological examinations in animals in which the intraluminal liner was used showed better healing, characterized by milder inflammation and increased amount of collagen. CONCLUSION: It can be concluded that the use of intraluminal protection decreases complication rates in colonic anastomosis and promotes better healing.


OBJETIVO: Testar o uso da proteção intraluminal na anastomose colônica sem preparo intestinal. O protetor intraluminal usado foi confeccionado a partir da submucosa de suíno conservada em glicerina, e fixado a 10 cm cranialmente ao sítio anastomótico. Essa técnica foi comparada com a técnica de anastomose colônica término-terminal sem uso do protetor intraluminal. MÉTODOS: Foram utilizados 28 cães divididos em dois grupos de 14 animais cada. A avaliação foi através de exames clínicos e histopatológicos. A avaliação anatomo-patológica foi realizada no quarto e vigésimo primeiro dias de pós-operatório. RESULTADOS: Um maior número de casos de morbi-mortalidade foi observado nos animais operados sem o protetor intraluminal. O exame histopatológico dos animais nos quais foram usados os protetores intraluminais mostrou melhor cicatrização, caracterizada por processo inflamatório mais discreto e maior quantidade de colágeno. CONCLUSÃO: O uso do protetor diminui o número de complicações em anastomoses de cólon e melhora a cicatrização.


Subject(s)
Animals , Female , Dogs , Anastomosis, Surgical/methods , Colon/surgery , Glycerol/therapeutic use , Intestinal Mucosa/transplantation , Anastomosis, Surgical/adverse effects , Anastomosis, Surgical/mortality , Collagen , Inflammation , Models, Animal , Postoperative Complications , Swine , Surgical Wound Dehiscence/etiology , Wound Healing
8.
Acta Cir Bras ; 21(6): 416-21, 2006.
Article in Portuguese | MEDLINE | ID: mdl-17160255

ABSTRACT

PURPOSE: To verify the development of blood vessels between the greater omentum and the liver in the presence of distinct liver blood intake blockages. METHODS: Two hundred and eighty conventional male Wistar rats were used, divided into 5 groups: control (n=35), laparotomy (n=35); hepatic artery ligature (n=70), ligature of the right-hand branch of the portal vein (n=70); and ligature of both blood vessels (n=70). The last three groups were divided into two subgroups each (n=35), according to the presence or absence of the transposition of the greater omentum onto the right hepatic lobe. The postoperative periods were 1, 3, 7, 15, 30, 60 and 90 days. At the end of each period, the greater omentum and right hepatic lobe were collected for histopathological examination. The presence of blood vessels between the referred tissues was verified by the administration of Indian ink as a marker of vascular lumen. RESULTS: Macroscopic and microscopic observation and the dye marker demonstrated the distribution of blood vessels between the greater omentum and liver tissues. CONCLUSION: The greater omentum was capable of developing blood vessels when fixed to the parenchyma of the liver after the suppression of hepatic blood flow.


Subject(s)
Hepatic Artery/surgery , Liver/blood supply , Neovascularization, Physiologic/physiology , Omentum/blood supply , Animals , Ligation , Liver/surgery , Male , Models, Animal , Omentum/surgery , Portal Vein , Postoperative Period , Rats , Rats, Wistar , Regional Blood Flow/physiology , Vascular Endothelial Growth Factors
9.
Acta cir. bras ; 21(6): 416-421, Nov.-Dec. 2006. ilus
Article in English | LILACS | ID: lil-440749

ABSTRACT

PURPOSE: To verify the development of blood vessels between the greater omentum and the liver in the presence of distinct liver blood intake blockages. METHODS: Two hundred and eighty conventional male Wistar rats were used, divided into 5 groups: control (n=35), laparotomy (n=35); hepatic artery ligature (n=70), ligature of the right-hand branch of the portal vein (n=70); and ligature of both blood vessels (n=70). The last three groups were divided into two subgroups each (n=35), according to the presence or absence of the transposition of the greater omentum onto the right hepatic lobe. The postoperative periods were 1, 3, 7, 15, 30, 60 and 90 days. At the end of each period, the greater omentum and right hepatic lobe were collected for histopathological examination. The presence of blood vessels between the referred tissues was verified by the administration of Indian ink as a marker of vascular lumen. RESULTS: Macroscopic and microscopic observation and the dye marker demonstrated the distribution of blood vessels between the greater omentum and liver tissues. CONCLUSION: The greater omentum was capable of developing blood vessels when fixed to the parenchyma of the liver after the suppression of hepatic blood flow.


OBJETIVO: Verificar o desenvolvimento de vasos sanguíneos entre o omento maior e o fígado em presença de diferentes bloqueios do aporte sanguíneo hepático. MÉTODOS: Foram utilizados 280 ratos machos, Wistar, convencional, divididos em 5 grupos: controle (n = 35), com laparotomia (n = 35), com ligadura da artéria hepática própria (n = 70), com ligadura do ramo direito da veia porta (n = 70) e com ligadura de ambos vasos sanguíneos (n = 70). Os três últimos grupos foram divididos em dois subgrupos (n = 35), de acordo com a transposição ou não do omento maior no lobo direito do fígado. Os períodos de pós-operatório foram de 1, 3, 7, 15, 30, 60 e 90 dias. Em cada período foram coletados o omento maior e o lobo direito do fígado para exame histopatológico. Presença de vasos sanguíneos entre os referidos tecidos foi verificada pela administração da tinta nanquim como marcador de lúmen vascular. RESULTADOS: As observações macroscópicas, microscópicas e do marcador tintorial demonstraram a distribuição dos vasos sanguíneos entre o omento maior transposto e o tecido hepático. CONCLUSÃO: O omento maior foi capaz de desenvolver vasos sanguíneos quando fixado junto ao parênquima do fígado, após supressão do fluxo sanguíneo hepático.


Subject(s)
Animals , Male , Rats , Hepatic Artery/surgery , Liver/blood supply , Neovascularization, Physiologic/physiology , Omentum/blood supply , Liver/surgery , Models, Animal , Omentum/surgery , Portal Vein , Postoperative Period , Rats, Wistar , Regional Blood Flow/physiology , Vascular Endothelial Growth Factors
10.
Rev. Col. Bras. Cir ; 33(6): 375-379, nov.-dez. 2006. tab, ilus
Article in Portuguese | LILACS | ID: lil-442051

ABSTRACT

OBJETIVO: Analisar a aplicabilidade da anestesia local da região inguinal no tratamento da hérnia inguinal. MÉTODO: Foram estudados os dados de 1560 pacientes submetidos ao tratamento operatório para cura de hérnia inguinal, entre maio de 1996 e dezembro de 2003, pela técnica de Lichtenstein, sob anestesia local da região inguinal associada à sedação. Foram analisados so seguintes dados: idade,sexo,índice de massa corporal, número de recidivas, as intercorrências pré e pós-operatórias, tempo de permanência hospitalar. Os tipos de hérnia foram classificados segundo Nyhus. RESULTADOS: Todas as operações foram concluídas sob a anestesia local e sedação não sendo necessário nenhuma complementação. As complicações pós-operatórias ocorreram em 7,16 por cento dos pacientes, nenhum deles necessitou de reinternação. CONCLUSÕES: A anestesia loco-regional da região inguinal na totalidade dos casos produziu conforto para os pacientes e boas condições de operabilidade para os cirurgiões.


BACKGROUND: This study aimed at showing the feasibility of local-regional anesthesia in inguinal hernia repair using the technique of Lichtenstein. METHODS: 1560 patients were operated between May 1996 and December 2003. They were submitted to 1560 surgeries by means of the Lichtenstein technique, operated under local-regional anesthesia in inguinal region. Age, gender, Nyhus classification, and body mass index were analyzed. RESULTS: The post-operative complications had occurred in 7,16 percent of the patients. Hospitalization average were 6:00 hours. CONCLUSION: We concluded that local-regional anesthesia in the inguinal region provides the same level of comfort for patients as well as for surgeons with the advantage of imposing shorter hospital stay.

11.
World J Surg ; 29(12): 1623-9, 2005 Dec.
Article in English | MEDLINE | ID: mdl-16317486

ABSTRACT

There is still controversy about the immunologic function of autotransplanted splenic tissue. In this study, splenic autotransplantation was performed in the abdominal cavity of mice, and the plaque-forming cell (PFC) assay was used to investigate the frequency of antibody-forming cells in response to sheep red blood cell (SRBC) immunization. BALB/c mice were divided into four groups according to the location of the autogenous graft: intraomental (IO), free peritoneal splenosis (FPS), retroperitoneal (RP), and nongrafted control (CT). Thirty days after surgery the mice were immunized intraperitoneally with SRBCs, and 4 days later splenic immunoglobulin M anti-SRBC-secreting cells were determined by counting the number of PFCs. All the immunized mice showed increased numbers of PFCs that were about 2 logs higher than those in the the nonimmunized controls (P < 0.005). The frequencies of anti-SRBC-producing cells in the tissues grafted in various sites of the abdominal cavity (IO, FPS, RP), in the normal spleen from nonoperated controls (CT), or in the sham-operated control group (SCT) were not notably different (5582 +/- 2475 PFC/10(7) cells for IO; 4849 +/- 1856 for FPS; 6604 +/- 2903 for RP; 5940 +/- 5029 for CT; and 6172 +/- 2203 for SCT). Similar histology with small architectural variations was observed in all implants; less white pulp was involved, and there was more congestion in the red pulp, with extensive sinusoids and reticular fiber proliferation. This study shows that the T cell-dependent antibody response in implanted splenic tissues is as efficient as in the intact spleen, with no difference between the graft sites studied. This immune response does not depend on the slight architectural variations observed in the splenic implants.


Subject(s)
Antibody Formation/physiology , Antibody-Producing Cells/physiology , Peritoneal Cavity/surgery , Spleen/immunology , Spleen/transplantation , Splenosis/immunology , Animals , Cell Count , Female , Hemolytic Plaque Technique , Mice , Mice, Inbred BALB C , Peritoneal Cavity/pathology , Spleen/pathology , Splenosis/pathology , Transplantation, Autologous
12.
Rev. bras. ciênc. vet ; 12(1/3): 84-88, jan.-dez. 2005. tab, graf
Article in Portuguese | LILACS | ID: lil-435912

ABSTRACT

O presente estudo visa comparar os fios de ácido poliglicólico e de poliglactina 910 em ileocistoplastia em cães. Utilizaram-se 24 cadelas, SRD (sem raça definida), adultas, pesando em média 15kg, divididos em dois grupos iguais, os quais foram submetidos a ileocistoplastia. No grupo A empregou-se o fio de poliglactina 910 e no B o fio de ácido poliglicólico. Os animais foram acompanhados até o 422 dia de pós-operatório, sendo que no 72, 142, 212, 282, 352 e 422 dois animais de cada grupo foram necropsiados para retirada da bexiga visando análise histopatológica da linha de sutura. Estipulou-se escores de O a 3 para reação inflamatória e absorção e de 1 a 3 para fibrose (cicatrização). Esses dados foram submetidos atratamento estatístico (teste x2 - Qui-quadrado) onde a = 0,05. Nos animais do grupo A, do 72 ao 422 dia observou-se reação inflamatória compatível com o período, enquanto os cães do grupo B, além da reação inflamatória, demonstravam também presença de supuração até o 352 dia (p<0,05). Os cães do grupo A apresentaram sinais progressivos de fibrose, a partir do 72 dia, enquanto os cães do grupo B só vieram a apresentar tais sinais após 21 dias. No 212 dia os cães do grupo B demonstraram sinais de início do processo de hidrólise, e no grupo A estes sinais só foram evidenciados no 282 dia. Os cães do grupo B apresentaram sinais de calcificação na linha de sutura a partir do 212 dia, fato não observado em todo período nos animais do grupo A. Houve diferença significativa entre os fios utilizados no grupo A e no grupo B, no que se refere a reação inflamatória, grau de fibrose e calcificação na linha de sutura, caracterizando o fio de poliglactina 910 como mais indicado para enterocistoplastia em cães


Subject(s)
Dogs/surgery , Ileum , Polyglactin 910 , Polyglycolic Acid , Sutures , Transplantation, Autologous/veterinary , Urinary Bladder , General Surgery , Veterinary Medicine
13.
Acta Cir Bras ; 20 Suppl 1: 34-41, 2005.
Article in Portuguese | MEDLINE | ID: mdl-16186971

ABSTRACT

PURPOSE: To determine the usefulness of different radiological methods in the diagnoses of wooden foreign bodies (FB). METHODS: Eleven adult chickens were used. Each thigh received a puncture wound and in one of them a wooden splinter was introduced and left in place while in the contralateral it was introduced and removed (control group). After 7 days the animals where killed and the legs removed to be analyzed with conventional radiography (CR), ultrasonography (US), magnetic resonance and computed tomography. The results were viewed by 2 independent senior radiologists. RESULTS: Sensitivity was: CR--13.6%; US--63.6%; MR--59.1%; and CT--72.7%, with specificity of 100%, 100%, 95.5%, and 95.5%, respectively. The positive predictive value for CR and US was 100%, 95% for CT 95% and 93.8% for MR. CT had a negative predictive value of 78.3%, while US, MR, and CR had 73.7%, 70.1%, and 53.7%, respectively. The accuracy for CT was 84.1%, followed by US--81.8%, RM--77.3%, and CR--56.8%. Inflammatory reaction was histologically demonstrated in all thighs containing FB. CONCLUSION: CR showed a poor performance to detect wooden FB in chickens, while US and CT seem to be the best option, followed by RM.


Subject(s)
Foreign Bodies/diagnosis , Models, Animal , Thigh/injuries , Wood , Wounds, Stab/diagnosis , Animals , Chickens , Foreign Bodies/diagnostic imaging , Foreign-Body Reaction/pathology , Magnetic Resonance Imaging , Reproducibility of Results , Sensitivity and Specificity , Soft Tissue Injuries/diagnosis , Soft Tissue Injuries/diagnostic imaging , Statistics, Nonparametric , Thigh/diagnostic imaging , Tomography, X-Ray Computed , Ultrasonography , Wounds, Stab/diagnostic imaging
14.
Rev. Col. Bras. Cir ; 32(4): 183-187, jul.-ago. 2005.
Article in Portuguese | LILACS | ID: lil-417998

ABSTRACT

OBJETIVOS: A videocirurgia com tecnologia robótica é um avanço médico e tecnológico recente, que tem no conceito de cirurgia-solo (sem auxiliares) uma das aplicações práticas que podem permitir maior controle e precisão. Este estudo prospectivo foi desenhado para avaliar a curva de aprendizado da cirurgia-solo com o AESOP 3000 para colecistectomia laparoscópica, avaliando resultados e aplicações desta nova técnica. MÉTODO: Quinze pacientes foram submetidos à cirurgia vídeo-laparoscópica com auxílio de tecnologia robótica, utilizando a câmera com comando de voz AESOP 3000 e um braço mecânico fixo, permitindo a realização dos procedimentos sob o conceito de cirurgia-solo. A câmera posicionada no trocarte umbilical, foi ajustada para receber comando de voz através do transmissor HERMES, permitindo também a gravação de posições-chave. Um braço mecânico foi ligado à mesa cirúrgica para retração fixa de órgãos quando necessário. RESULTADOS: As cirurgias transcorreram sem anormalidades, sem necessidade de conversão, sendo necessária a retirada do AESOP para realização de câmera manual em um caso. O tempo operatório foi aumentado para permitir o tempo de ajuste do aparelho que foi, em média, de 21,9 min. Não foram documentadas complicações locais ou sistêmicas pós-operatórias. Quanto ao tempo de internação, a maioria dos pacientes recebeu alta em 24-48hs (86,7 por cento). O grau de satisfação subjetiva da equipe com o auxiliar robótico foi de 3,94, em um máximo de 5,0. CONCLUSÕES: As potenciais vantagens do AESOP 3000 e dos sistemas de telecirurgia podem ser vislumbradas nesta avaliação inicial. A curva de aprendizado é simples e permitiu a realização das cirurgias por residentes em treinamento. Apesar de maior tempo operatório que o procedimento laparoscópico padrão, a assistência robótica mostrou maior precisão e estabilidade de câmera, sendo um passo inicial para a realização de videocirurgia robótica à distância.

15.
J. bras. med ; 88(1/2): 38-40, jan.- fev. 2005.
Article in Portuguese | LILACS | ID: lil-561178

ABSTRACT

O trauma duodenal representa uma lesão de difícil diagnóstico, que traz consigo altas taxas de morbimortalidade quando provoca feridas complexas. O tratamento atual consagrado das lesões duodenais graves consiste em procedimentos cirúrgicos extensos. Uma nova abordagem está sendo estudada com novos materiais, como as colas sintéticas, para que se possa reduzir o tempo operatório, as complicações e para que possa ser aplicada em lesões associadas com resultados pelo menos similares aos dos tratamentos clássicos.


Duodenal trauma causes a lesion of difficult diagnosis associated with high rates of morbimortality when injuries...


Subject(s)
Humans , Animals , Cattle , Duodenum/injuries , Abdominal Injuries/surgery , Abdominal Injuries/complications , Abdominal Injuries/etiology , Abdominal Injuries/physiopathology , Abdominal Injuries/therapy , Tissue Adhesives/therapeutic use
16.
Rev. bras. ciênc. vet ; 12(1-3): 1-3, 2005.
Article in Portuguese | LILACS-Express | LILACS, VETINDEX | ID: biblio-1491290

ABSTRACT

O presente estudo visa comparar os fios de ácido poliglicólico e de poliglactina 910 em ileocistoplastia em cães. Utilizaramse24 cadelas, SRD (sem raça definida), adultas, pesando em média 15kg, divididos em dois grupos iguais, os quais foramsubmetidos a ileocistoplastia. No grupo A empregou-se o fio de poliglactina 910 e no B o fio de ácido poliglicólico. Os animaisforam acompanhados até o 42o dia de pós-operatório, sendo que no 7o, 14o, 21o, 28o, 35o e 42o dois animais de cada grupoforam necropsiados para retirada da bexiga visando análise histopatológica da linha de sutura. Estipulou-se escores de 0 a 3para reação inflamatória e absorção e de 1 a 3 para fibrose (cicatrização). Esses dados foram submetidos atratamentoestatístico (teste x2 Qui-quadrado) onde a = 0,05. Nos animais do grupo A, do 7o ao 42o dia observou-se reação inflamatóriacompatível com o período, enquanto os cães do grupo B, além da reação inflamatória, demonstravam também presença desupuração até o 35o dia (p 0,05). Os cães do grupo A apresentaram sinais progressivos de fibrose, a partir do 7o dia, enquantoos cães do grupo B só vieram a apresentar tais sinais após 21 dias. No 21o dia os cães do grupo B demonstraram sinais deinício do processo de hidrólise, e no grupo A estes sinais só foram evidenciados no 28o dia. Os cães do grupo B apresentaramsinais de calcificação na linha de sutura a partir do 21o

17.
Acta cir. bras ; 20(supl.1): 34-41, 2005.
Article in Portuguese | LILACS | ID: lil-414636

ABSTRACT

Avaliar diferentes métodos radiológicos no diagnóstico de corpos estranhos (CEs) de madeira. MÉTODOS: Foram utilizados 11 frangos adultos. Realizou-se lesão perfurante, em cada sobrecoxa do animal. Em um dos lados, foi introduzida e deixada uma farpa de madeira e, na sobrecoxa contralateral, esse mesmo objeto foi introduzido e retirado (Grupo Controle). Após sete dias, os animais foram mortos e tiveram seus membros retirados para avaliação por radiografia simples (RS), ultra-sonografia (US), tomografia computadorizada (TC) e ressonância magnética (RM). Cada exame foi avaliado, independentemente, por dois radiologistas experientes. RESULTADOS: A sensibilidade foi 13,6 por cento para RS, 63,3 por cento para US, 59,1 por cento para RM e 72,7 por cento para TC, com especificidades de 100 por cento, 100 por cento, 95,5 por cento e 95,5 por cento, respectivamente. O valor preditivo positivo foi de 100 por cento para RS e US, de 95 por cento para TC e de 93,8 por cento para RM, enquanto o valor preditivo negativo foi de 53,7 por cento, 73,7 por cento, 78,3 por cento e 70,1 por cento, respectivamente. A acurácia foi de 84,1 por cento, para TC, de 81,8 por cento para US, de 77,3 por cento para RM e de 56,8 por cento para RS. Comprovou-se, histologicamente, presença de reação inflamatória em todas as sobrecoxas que continham CE. CONCLUSÃO: RS apresenta pequena utilidade na detecção radiológica de CE de madeira em frango, devendo-se optar pelo emprego de US e TC, seguido por RM.


Subject(s)
Animals , Foreign Bodies/diagnosis , Models, Animal , Thigh/injuries , Wood , Wounds, Stab/diagnosis , Chickens , Foreign Bodies , Foreign Bodies , Foreign-Body Reaction/pathology , Magnetic Resonance Imaging , Reproducibility of Results , Sensitivity and Specificity , Statistics, Nonparametric , Soft Tissue Injuries/diagnosis , Soft Tissue Injuries , Soft Tissue Injuries , Tomography, X-Ray Computed , Thigh , Thigh , Wounds, Stab , Wounds, Stab
18.
Article in Portuguese | LILACS-Express | LILACS, VETINDEX | ID: biblio-1456144

ABSTRACT

PURPOSE: To determine the usefulness of different radiological methods in the diagnoses of wooden foreign bodies (FB). METHODS: Eleven adult chickens were used. Each thigh received a puncture wound and in one of them a wooden splinter was introduced and left in place while in the contralateral it was introduced and removed (control group). After 7 days the animals where killed and the legs removed to be analyzed with conventional radiography (CR), ultrasonography (US), magnetic resonance and computed tomography. The results were viewed by 2 independent senior radiologists. RESULTS: Sensitivity was: CR - 13.6%; US - 63.6%; MR - 59.1%; and CT - 72.7%, with specificity of 100%, 100%, 95.5%, and 95.5%, respectively. The positive predictive value for CR and US was 100%, 95% for CT 95% and 93.8% for MR. CT had a negative predictive value of 78.3%, while US, MR, and CR had 73.7%, 70.1%, and 53.7%, respectively. The accuracy for CT was 84.1%, followed by US - 81.8%, RM - 77.3%, and CR - 56.8%. Inflammatory reaction was histologically demonstrated in all thighs containing FB. CONCLUSION: CR showed a poor performance to detect wooden FB in chickens, while US and CT seem to be the best option, followed by RM.


Avaliar diferentes métodos radiológicos no diagnóstico de corpos estranhos (CEs) de madeira. MÉTODOS: Foram utilizados 11 frangos adultos. Realizou-se lesão perfurante, em cada sobrecoxa do animal. Em um dos lados, foi introduzida e deixada uma farpa de madeira e, na sobrecoxa contralateral, esse mesmo objeto foi introduzido e retirado (Grupo Controle). Após sete dias, os animais foram mortos e tiveram seus membros retirados para avaliação por radiografia simples (RS), ultra-sonografia (US), tomografia computadorizada (TC) e ressonância magnética (RM). Cada exame foi avaliado, independentemente, por dois radiologistas experientes. RESULTADOS: A sensibilidade foi 13,6% para RS, 63,3% para US, 59,1% para RM e 72,7% para TC, com especificidades de 100%, 100%, 95,5% e 95,5%, respectivamente. O valor preditivo positivo foi de 100% para RS e US, de 95% para TC e de 93,8% para RM, enquanto o valor preditivo negativo foi de 53,7%, 73,7%, 78,3% e 70,1%, respectivamente. A acurácia foi de 84,1%, para TC, de 81,8% para US, de 77,3% para RM e de 56,8% para RS. Comprovou-se, histologicamente, presença de reação inflamatória em todas as sobrecoxas que continham CE. CONCLUSÃO: RS apresenta pequena utilidade na detecção radiológica de CE de madeira em frango, devendo-se optar pelo emprego de US e TC, seguido por RM.

20.
Rev. bras. ginecol. obstet ; 23(6): 365-jul. 2001. ilus, tab
Article in Portuguese | LILACS | ID: lil-331486

ABSTRACT

Objetivo: comparar o grau de aderências no ovário de acordo com diferentes tipos de fechamento do córtex ovariano. Métodos: quinze coelhos foram distribuídos aleatoriamente em três grupos, de acordo com o tipo de fechamento do córtex ovariano, sendo utilizados a diatermia bipolar, a poliglactina 910 5-0 e o categute simples 5-0. Após 2 semanas os animais foram sacrificados e o grau de aderências do ovário direito foi avaliado segundo a classificação de Diamond. O ovário esquerdo, não incisado, serviu de controle. Na análise estatística foram empregados a análise de variância (ANOVA), o teste de Scheffé e o teste t de Student. Resultados: as médias dos escores de aderência para o grupo bipolar, poliglactina e categute simples foram 0,7, 1,5 e 2,0, respectivamente. A análise de variância detectou diferença significativa (p=0,02) entre os três grupos. Usando-se o teste de Scheffé para a comparação dos grupos dois a dois, encontrou-se uma diferença significativa apenas entre o grupo bipolar e o grupo do categute simples. Comparando-se o grupo em que se usaram suturas (independente do material empregado) com o grupo bipolar verificou-se uma diferença estatisticamente significativa (p=0,01) entre as médias dos escores de aderência do ovário direito (1,8 e 0,7, respectivamente). Conclusões: os resultados obtidos no presente estudo estão de acordo com os dados da literatura, indicando que o fechamento por segunda intenção do córtex ovariano é mais vantajoso, em relação à formação de aderências, que o fechamento como uso de suturas.


Subject(s)
Animals , Female , Rabbits , Ovary , Infertility , Peritoneum
SELECTION OF CITATIONS
SEARCH DETAIL
...