Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Int J Angiol ; 33(1): 29-35, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38352642

ABSTRACT

Objectives Few studies have evaluated the outcomes of whole blood microplegia in adult cardiac surgery. Our novel protocol includes removing the crystalloid portion and using the Quest Myocardial Protection System (MPS) for the delivery of del Nido additives in whole blood. This study sought to compare early and late clinical outcomes of whole blood del Nido microplegia (BDN) versus cold blood cardioplegia (CBC) following adult cardiac surgery. Materials and Methods A total of 361 patients who underwent cardiac surgery using BDN were compared with a contemporaneous control group of 934 patients receiving CBC. Propensity matching yielded 289 BDN and 289 CBC patients. Chi-square analysis and Fisher's exact test were performed to compare preoperative, operative, and postoperative characteristics on the matched data. Primary outcome was operative mortality, and secondary outcomes included clinical outcomes such as stroke, cardiac arrest, and intra-aortic balloon pump use. The Kaplan-Meier method was used to compare actuarial survival between the two groups using a log-rank test. Results After matching, preoperative characteristics and surgery type were similar between groups. Cardioplegia type did not affect the primary end point of operative mortality. The rate of postoperative intra-aortic balloon pump was lower in BDN patients compared with CBC patients (0 vs. 2%; p = 0.01). There was no difference in late survival. Conclusion Our novel protocol BDN was comparable with CBC, with similar clinical outcomes and no difference in operative mortality or actuarial survival. Further studies should evaluate the long-term outcomes of this technique.

2.
Thorac Cardiovasc Surg ; 69(5): 437-444, 2021 Aug.
Article in English | MEDLINE | ID: mdl-32252113

ABSTRACT

BACKGROUND: Numerous studies have documented the safety of alternatives access (AA) transcatheter aortic valve replacement (TAVR) for patients who are not candidates for transfemoral or surgical approach. There is a scarcity of studies relating use of AA TAVR in nonagenarian patients, a high-risk, frail group. Our study sought to investigate the clinical outcomes of nonagenarians who underwent AA TAVR for aortic stenosis, with comparison of nonagenarians age ≥90 years with patients age <90 years. METHODS: A cohort study of 171 consecutive patients undergoing AA TAVR (transapical [TA, n = 101, 59%], transaxillary [TAX, n = 56, 33%], transaortic [TAO, n = 11, 6%], and transcarotid [TC, n = 3, 2%]) from 2012 to 2019 was analyzed. Baseline, operative, and postoperative characteristics, as well as actuarial survival outcomes, were compared. RESULTS: AA TAVR patients had decreased aortic valve gradients with no difference detected in nonagenarians and younger patients. Operative mortality was 8% (n = 14; nine TA, three TAO, and two TAX). Compared to younger patients, significantly more nonagenarians were recorded to have new onset atrial fibrillation (7 vs. 5%, p < 0.01*). No significant difference in mortality or postoperative complications, such as stroke, pacemaker requirements, was detected. Actuarial survival at 1 and 5 years was 86 versus 87% (nonagenarians vs younger patients) and 36 versus 22%, respectively, with log-rank = 0.97. CONCLUSION: AA TAVR in nonagenarian patients who are not candidates for transfemoral approach can be efficaciously performed with comparable clinical outcomes to younger patients, age <90 years. Furthermore, some access sites should be avoided when possible; notably TA was associated with increased mortality, stroke, and new onset atrial fibrillation.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Cardiac Catheterization , Catheterization, Peripheral , Transcatheter Aortic Valve Replacement , Age Factors , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Cardiac Catheterization/adverse effects , Cardiac Catheterization/mortality , Catheterization, Peripheral/adverse effects , Catheterization, Peripheral/mortality , Databases, Factual , Female , Humans , Male , Middle Aged , Postoperative Complications/etiology , Recovery of Function , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome
3.
Tex Heart Inst J ; 47(2): 108-116, 2020 04 01.
Article in English | MEDLINE | ID: mdl-32603472

ABSTRACT

Warm blood cardioplegia has been an established cardioplegic method since the 1990s, yet it remains controversial in regard to myocardial protection. This review will describe the physiologic and technical concepts behind warm blood cardioplegia, as well as outline the current basic and clinical research that evaluates its usefulness. Controversies regarding this technique will also be reviewed. A long history of experimental data indicates that warm blood cardioplegia is safe and effective and thus suitable myocardial protection during cardiopulmonary bypass surgeries.


Subject(s)
Cardiac Surgical Procedures , Heart Arrest, Induced/methods , Intraoperative Care/methods , Myocardial Reperfusion Injury/prevention & control , Humans
4.
Thorac Cardiovasc Surg ; 68(8): 752-754, 2020 12.
Article in English | MEDLINE | ID: mdl-31539921

ABSTRACT

Sternal instability after cardiac surgery can lead to poor bony healing, as well as deep sternal wound infections and mediastinitis. Rigid plate fixation is associated with greater stability and fewer complications compared with wire cerclage, however, rigid plate fixation alone lacks posterior stability of the sternum and may be less effective in morbidly obese or osteoporotic patients. This article describes a surgical technique of combined rigid plate fixation and wire cerclage that provides 360-degree stabilization for sternotomies in high-risk patients. We employed this technique in 40 patients with no incidence of deep sternal wound infection.


Subject(s)
Bone Plates , Bone Wires , Cardiac Surgical Procedures , Fracture Fixation, Internal/instrumentation , Sternotomy , Sternum/surgery , Cardiac Surgical Procedures/adverse effects , Fracture Fixation, Internal/adverse effects , Humans , Mediastinitis/microbiology , Mediastinitis/prevention & control , Prosthesis Design , Risk Assessment , Risk Factors , Sternotomy/adverse effects , Sternum/diagnostic imaging , Surgical Wound Infection/microbiology , Surgical Wound Infection/prevention & control , Treatment Outcome
5.
J Card Surg ; 35(1): 21-27, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31794084

ABSTRACT

OBJECTIVES: Stroke is a devastating complication of transcatheter aortic valve replacement (TAVR). Many studies have investigated risk factors for postoperative stroke, but reliable predictors are not yet well-established. The objective of this study was to further characterize the predictors and outcomes of stroke after TAVR. METHODS: This is a retrospective cohort study of 1022 patients who underwent TAVR at a single institution between 2012 and 2018. Multivariable logistic regression analysis was used to identify independent predictors of postoperative stroke and Kaplan-Meier method to compare 1-year survival in patients with and without postoperative stroke. RESULTS: Postoperatively, 36 patients experienced a stroke (3.5%) with most developing multiple (63.9%, N = 23), and often bilateral infarcts (50.0%, N = 18). Stroke patients more commonly had peripheral arterial disease (P = .032) and carotid stenosis (P = .013) and were less likely to receive predeployment balloon aortic valvuloplasty (P = .005). Alternative access approach (odds ratio [OR], 2.322; 95% confidence interval [CI]: 1.067-5.054) and history of transient ischemic attack (OR, 2.373; 95% CI: 1.026-5.489) were identified as independent predictors of postoperative stroke. Stroke patients more frequently developed postoperative complications, including prolonged ventilation (P < .001), major vascular complications (P < .001), and new-onset dialysis (P < .001). Operative mortality was greater in stroke patients (19.4% vs 3.7%; P < .001), and 1-year Kaplan-Meier estimates revealed worsened survival (log-rank P = .002). CONCLUSIONS: Alternative access approach and a history of transient ischemic attack emerged as independent predictors of postoperative stroke. Patients with stroke suffered more complications and had worse survival, underscoring the importance of characterizing the stroke risk in these patients.


Subject(s)
Postoperative Complications/etiology , Stroke , Transcatheter Aortic Valve Replacement , Cohort Studies , Forecasting , Humans , Ischemic Attack, Transient , Logistic Models , Postoperative Complications/epidemiology , Retrospective Studies , Stroke/epidemiology , Stroke/etiology
6.
J Card Surg ; 35(2): 360-366, 2020 Feb.
Article in English | MEDLINE | ID: mdl-31794109

ABSTRACT

BACKGROUND: Patient-prosthesis mismatch (PPM) has been shown to be associated with adverse outcomes after surgical aortic valve replacement. There is limited data on its risk and impact after transcatheter aortic valve replacement (TAVR), especially with the newer generation heart valves. OBJECTIVES: The objective of this study is to investigate the incidence, predictors, and clinical outcomes of PPM after TAVR. METHODS: This is a retrospective study of 991 consecutive patients who underwent TAVR procedure at a tertiary referral center, between April 2012 and February 2019. Patients were stratified by the presence or absence of PPM, defined as an effective orifice area/body surface area ratio ≤0.85 cm2 /m2 . Multivariable logistic regression analysis was used to determine independent predictors of PPM. Kaplan-Meier survival estimates were used to determine overall 5-year survival. RESULTS: PPM was encountered in 27.6% of patients. In multivariable analysis, age less than 70 years (P = .062), body mass index (BMI) more than 30 (P = .0057), history of atrial fibrillation (P = .0004), black race (P = .0078), and Sapien 3 sizes 20 and 23 mm (P < .0001)emerged as independent predictors of PPM. Sapien 3 valve size 20/23 mm was associated with higher risk of PPM compared to other valve types. Patients with PPM had comparable postoperative outcomes and overall 5-year survival. There was no significant difference in postoperative complications between patient groups. PPM was not associated with worse overall survival (56% for both PPM and no-PPM patients, log-rank P = .80). CONCLUSIONS: Younger age, atrial fibrillation, black race, higher BMI were predictors of PPM. Smaller sizes balloon-expandable valves had a higher risk of PPM.


Subject(s)
Heart Valve Prosthesis/adverse effects , Transcatheter Aortic Valve Replacement/adverse effects , Age Factors , Aged , Aged, 80 and over , Body Mass Index , Female , Forecasting , Humans , Male , Retrospective Studies , Risk , Survival Rate , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome
7.
Catheter Cardiovasc Interv ; 93(6): 1170-1172, 2019 05 01.
Article in English | MEDLINE | ID: mdl-30790421

ABSTRACT

Valve-in-valve transcatheter aortic valve replacement (VIV TAVR) has emerged as a preferable option for high surgical risk patients requiring redo aortic valve replacement. However, VIV TAVR may restrict flow, especially in small native aortic valves. To remedy this, bioprosthetic valve fracture has been utilized to increase the effective orifice area and improve hemodynamics. We present three cases in which bioprosthetic valve fracture was used to increase hemodynamic flow in VIV TAVR procedures.


Subject(s)
Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Bioprosthesis , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Prosthesis Failure , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Female , Heart Valve Prosthesis Implantation/adverse effects , Hemodynamics , Humans , Male , Prosthesis Design , Recovery of Function , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...