Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Pediatr Res ; 63(6): 691-6, 2008 Jun.
Article in English | MEDLINE | ID: mdl-18520333

ABSTRACT

Our goal was to study the feasibility of continuous noninvasive finger blood pressure (BP) monitoring in very young children, aged 0-4 y. To achieve this, we designed a set of small-sized finger cuffs based on the assessment of finger circumference. Finger arterial BP measured by a volume clamp device (Finapres technology) was compared with simultaneously measured intra-arterial BP in 15 very young children (median age, 5 mo; range, 0-48), admitted to the intensive care unit for vital monitoring. The finger cuff-derived BP waveforms showed good resemblance with the invasive arterial waveforms (mean root-mean-square error, 3 mm Hg). The correlation coefficient between both methods was 0.79 +/- 0.19 systolic and 0.74 +/- 0.24 diastolic. The correlation coefficient of beat-to-beat changes between both methods was 0.82 +/- 0.18 and 0.75 +/- 0.21, respectively. Three measurements were related to measurement errors (loose cuff application; wrong set-point). Excluding these erroneous measurements resulted in clinically acceptable measurement bias (-3.8 mm Hg) and 95% limits of agreement (-10.4 to + 2.8 mm Hg) of mean BP values. We conclude that continuous finger BP measurement is feasible in very young children. However, cuff application is critical, and the current set-point algorithm needs to be revised in very young children.


Subject(s)
Blood Pressure Determination/methods , Blood Pressure , Fingers/blood supply , Algorithms , Arteries/physiopathology , Blood Pressure Determination/instrumentation , Blood Pressure Monitors , Child, Preschool , Critical Care , Equipment Design , Feasibility Studies , Humans , Infant , Infant, Newborn , Miniaturization , Netherlands , Reproducibility of Results
2.
Am J Cardiol ; 101(11): 1657-62, 2008 Jun 01.
Article in English | MEDLINE | ID: mdl-18489947

ABSTRACT

After Fontan operation, patients are limited in increasing cardiac output and in exercise capacity. This has been related to impaired preload or other factors leading to decreased global ventricular performance with stress. To study these factors, the stress responses of functionally univentricular hearts were assessed at rest and during low-dose dobutamine stress using cardiovascular magnetic resonance imaging. Thirty-two patients after Fontan completion at young age were included (27 with total cavopulmonary connection, 5 with atriopulmonary connection; mean age 13.3 years, range 7.5 to 22.2; 23 male patients; median follow-up after Fontan operation 8.1 years, range 5.2 to 17.8). A multiphase short-axis stack of 10 to 12 contiguous slices of the systemic ventricle was obtained at rest and during low-dose dobutamine stress cardiovascular magnetic resonance imaging (maximum 7.5 microg/kg/min). With stress-testing, heart rate, ejection fraction, and cardiac index increased adequately (p <0.001). There was an abnormal decrease in end-diastolic volume and an adequate decrease in end-systolic volume (p <0.001). Stroke volume did not change with stress testing (p = 0.15). At rest, dominant left ventricles had higher ejection fractions than dominant right ventricles (p = 0.01), but this difference disappeared with stress testing. In conclusion, a functionally univentricular heart after Fontan completion at young age has an adequate increase in ejection fraction with beta-adrenergic stimulation. However, as a result of impaired preload with stress, cardiac output can be increased only by increasing heart rate.


Subject(s)
Dobutamine/administration & dosage , Echocardiography, Stress/methods , Fontan Procedure/methods , Heart Defects, Congenital/surgery , Heart Ventricles/abnormalities , Magnetic Resonance Imaging/methods , Myocardial Contraction/physiology , Adolescent , Adult , Cardiotonic Agents/administration & dosage , Child , Cross-Sectional Studies , Dose-Response Relationship, Drug , Female , Follow-Up Studies , Heart Defects, Congenital/diagnosis , Heart Defects, Congenital/physiopathology , Heart Rate/physiology , Heart Ventricles/diagnostic imaging , Heart Ventricles/physiopathology , Humans , Injections, Intravenous , Male , Prognosis , Reproducibility of Results , Retrospective Studies , Severity of Illness Index
SELECTION OF CITATIONS
SEARCH DETAIL
...