Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 24
Filter
1.
Diagnostics (Basel) ; 14(7)2024 Mar 28.
Article in English | MEDLINE | ID: mdl-38611626

ABSTRACT

This review briefly introduces readers to an area where glycomics meets modern oncodiagnostics with a focus on the analysis of sialic acid (Neu5Ac)-terminated structures. We present the biochemical perspective of aberrant sialylation during tumourigenesis and its significance, as well as an analytical perspective on the detection of these structures using different approaches for diagnostic and therapeutic purposes. We also provide a comparison to other established liquid biopsy approaches, and we mathematically define an early-stage cancer based on the overall prognosis and effect of these approaches on the patient's quality of life. Finally, some barriers including regulations and quality of clinical validations data are discussed, and a perspective and major challenges in this area are summarised.

2.
PLoS One ; 19(3): e0300430, 2024.
Article in English | MEDLINE | ID: mdl-38498504

ABSTRACT

The glycoprofiling of two proteins, the free form of the prostate-specific antigen (fPSA) and zinc-α-2-glycoprotein (ZA2G), was assessed to determine their suitability as prostate cancer (PCa) biomarkers. The glycoprofiling of proteins was performed by analysing changes in the glycan composition on fPSA and ZA2G using lectins (proteins that recognise glycans, i.e. complex carbohydrates). The specific glycoprofiling of the proteins was performed using magnetic beads (MBs) modified with horseradish peroxidase (HRP) and antibodies that selectively enriched fPSA or ZA2G from human serum samples. Subsequently, the antibody-captured glycoproteins were incubated on lectin-coated ELISA plates. In addition, a novel glycoprotein standard (GPS) was used to normalise the assay. The glycoprofiling of fPSA and ZA2G was performed in human serum samples obtained from men undergoing a prostate biopsy after an elevated serum PSA, and prostate cancer patients with or without prior therapy. The results are presented in the form of an ROC (Receiver Operating Curve). A DCA (Decision Curve Analysis) to evaluate the clinical performance and net benefit of fPSA glycan-based biomarkers was also performed. While the glycoprofiling of ZA2G showed little promise as a potential PCa biomarker, the glycoprofiling of fPSA would appear to have significant clinical potential. Hence, the GIA (Glycobiopsy ImmunoAssay) test integrates the glycoprofiling of fPSA (i.e. two glycan forms of fPSA). The GIA test could be used for early diagnoses of PCa (AUC = 0.83; n = 559 samples) with a potential for use in therapy-monitoring (AUC = 0.90; n = 176 samples). Moreover, the analysis of a subset of serum samples (n = 215) revealed that the GIA test (AUC = 0.81) outperformed the PHI (Prostate Health Index) test (AUC = 0.69) in discriminating between men with prostate cancer and those with benign serum PSA elevation.


Subject(s)
Prostate-Specific Antigen , Prostatic Neoplasms , Male , Humans , Biomarkers, Tumor , Prostate/pathology , ROC Curve , Early Detection of Cancer , Prostatic Neoplasms/pathology , Glycoproteins , Polysaccharides
3.
Sensors (Basel) ; 24(4)2024 Feb 08.
Article in English | MEDLINE | ID: mdl-38400284

ABSTRACT

Prostate cancer (PCa) is the second most common cancer. In this paper, the isolation and properties of exosomes as potential novel liquid biopsy markers for early PCa liquid biopsy diagnosis are investigated using two prostate human cell lines, i.e., benign (control) cell line RWPE1 and carcinoma cell line 22Rv1. Exosomes produced by both cell lines are characterised by various methods including nanoparticle-tracking analysis, dynamic light scattering, scanning electron microscopy and atomic force microscopy. In addition, surface plasmon resonance (SPR) is used to study three different receptors on the exosomal surface (CD63, CD81 and prostate-specific membrane antigen-PMSA), implementing monoclonal antibodies and identifying the type of glycans present on the surface of exosomes using lectins (glycan-recognising proteins). Electrochemical analysis is used to understand the interfacial properties of exosomes. The results indicate that cancerous exosomes are smaller, are produced at higher concentrations, and exhibit more nega tive zeta potential than the control exosomes. The SPR experiments confirm that negatively charged α-2,3- and α-2,6-sialic acid-containing glycans are found in greater abundance on carcinoma exosomes, whereas bisecting and branched glycans are more abundant in the control exosomes. The SPR results also show that a sandwich antibody/exosomes/lectins configuration could be constructed for effective glycoprofiling of exosomes as a novel liquid biopsy marker.


Subject(s)
Carcinoma , Exosomes , Male , Humans , Exosomes/chemistry , Liquid Biopsy , Carcinoma/metabolism , Carcinoma/pathology , Lectins/analysis , Lectins/metabolism , Polysaccharides/analysis , Polysaccharides/metabolism
4.
Sensors (Basel) ; 23(12)2023 Jun 06.
Article in English | MEDLINE | ID: mdl-37420529

ABSTRACT

Protein-carbohydrate interactions happen to be a crucial facet of biology, discharging a myriad of functions. Microarrays have become a premier choice to discern the selectivity, sensitivity and breadth of these interactions in a high-throughput manner. The precise recognition of target glycan ligands among the plethora of others is central for any glycan-targeting probe being tested by microarray analyses. Ever since the introduction of the microarray as an elemental tool for high-throughput glycoprofiling, numerous distinct array platforms possessing different customizations and assemblies have been developed. Accompanying these customizations are various factors ushering variances across array platforms. In this primer, we investigate the influence of various extrinsic factors, namely printing parameters, incubation procedures, analyses and array storage conditions on the protein-carbohydrate interactions and evaluate these factors for the optimal performance of microarray glycomics analysis. We hereby propose a 4D approach (Design-Dispense-Detect-Deduce) to minimize the effect of these extrinsic factors on glycomics microarray analyses and thereby streamline cross-platform analyses and comparisons. This work will aid in optimizing microarray analyses for glycomics, minimize cross-platform disparities and bolster the further development of this technology.


Subject(s)
Body Fluids , Glycomics , Glycomics/methods , Microarray Analysis/methods , Polysaccharides , Ligands
5.
J Funct Biomater ; 14(3)2023 Mar 17.
Article in English | MEDLINE | ID: mdl-36976085

ABSTRACT

Screen-printing technology is a game changer in many fields including electrochemical biosensing. Two-dimensional nanomaterial MXene Ti3C2Tx was integrated as a nanoplatform to immobilise enzyme sarcosine oxidase (SOx) onto the interface of screen-printed carbon electrodes (SPCEs). A miniaturised, portable, and cost-effective nanobiosensor was constructed using chitosan as a biocompatible glue for the ultrasensitive detection of prostate cancer biomarker sarcosine. The fabricated device was characterised with energy-dispersive X-ray spectroscopy (EDX), electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). Sarcosine was detected indirectly via the amperometric detection of H2O2 formed during enzymatic reaction. The nanobiosensor could detect sarcosine down to 7.0 nM with a maximal peak current output at 4.10 ± 0.35 × 10-5 A using only 100 µL of a sample per measurement. The assay run in 100 µL of an electrolyte showed the first linear calibration curve in a concentration window of up to 5 µM with a slope of 2.86 µA·µM-1, and the second linear calibration curve in the range of 5-50 µM with a slope of 0.32 ± 0.01 µA·µM-1 (R2 = 0.992). The device provided a high recovery index of 92.5% when measuring an analyte spiked into artificial urine, and could be used for detection of sarcosine in urine for at least a period of 5 weeks after the preparation.

6.
Biomed Pharmacother ; 151: 113093, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35576661

ABSTRACT

Exosomes are considered to be a rich source of biomarkers, hence in this article we examine the best procedure for their isolation. We examine several isolation procedures, exosome storage conditions and other conditions affecting exosome production by prostate cell lines. We selected four different commercially available kits based on different principles to achieve exosome isolation, the best being magnetic-based. In addition, we found storage at - 20 °C to be good for storing isolated exosomes and that exosomes were produced from the cancerous prostate cell line 22Rv1 in much greater amounts than the non-cancerous prostate cell line RWPE1. We also found differences in the response of both cell lines in the production of exosomes as a result of stress, i.e. exposure to hydrogen peroxide and starvation. The effect of Triton X-100 on exosome lysis was examined using two different surfactant concentrations by analysis of the exosome count and change in the exosome size. The final part of the article details the advantages of the use of a 2D biochip prepared in-house over a commercially available 3D biochip for monitoring the interaction of exosomes via its surface receptors (CD63) with an immobilised ligand (anti-CD63 antibodies) using surface plasmon resonance. The final experiment shows the potential of lectin fluorescent microarrays for the analysis of glycans present in lysed exosomes.


Subject(s)
Exosomes , Prostatic Neoplasms , Biomarkers/metabolism , Cell Line , Exosomes/metabolism , Humans , Male , Microarray Analysis , Prostatic Neoplasms/metabolism
7.
Cancer Med ; 11(4): 968-982, 2022 02.
Article in English | MEDLINE | ID: mdl-35044085

ABSTRACT

BACKGROUND: Testicular cancer (TC) is the most frequent type of cancer among young men aged between 15 and 34 years. TC is treated using cisplatin, but 3%-5% of TC patients fail to respond to cisplatin, with a very bad to fatal prognosis. Accordingly, it is most important to quickly and readily identify those TC patients who are resistant to cisplatin treatment. METHODS: This study seeks to investigate changes in the glycosylation associated with cisplatin resistance to TC cell lines. RESULTS: A specific glycoprofiling of human chorionic gonadotropin (hCG) was analysed in three TC cell lines and one cell line of female origin. A typical calibration curve for hCG glycoprofiling showed a dynamic range up to 50 ng/ml, with a limit of detection of 0.3 ng/ml and assay reproducibility represented by relative standard deviation of 3.0%. Changes in the glycan signatures on hCG were analysed in cisplatin-sensitive cell lines and in their cisplatin-resistant sub-lines using an enzyme-linked lectin assay (ELLA) protocol. An immobilised antibody was applied to a selective capture of hCG from a cytoplasmic fraction of cell lysates with final incubation using a lectin from a panel of 17 lectins. CONCLUSION: The results suggest that one particular lectin Dolichos biflorus agglutinin (DBA) can selectively discriminate sensitive TC cell lines from resistant TC cell lines. Moreover, there are additional lectins which can provide useful information about the strength of cisplatin resistance.


Subject(s)
Cisplatin , Testicular Neoplasms , Adolescent , Adult , Cell Line , Chorionic Gonadotropin/metabolism , Cisplatin/pharmacology , Drug Resistance, Neoplasm , Female , Humans , Lectins , Male , Neoplasms, Germ Cell and Embryonal , Polysaccharides/pharmacology , Reproducibility of Results , Testicular Neoplasms/drug therapy , Testicular Neoplasms/metabolism , Young Adult
8.
Front Oncol ; 11: 735338, 2021.
Article in English | MEDLINE | ID: mdl-34956866

ABSTRACT

Colorectal cancer (CRC) is one of the most common types of cancer among men and women worldwide. Efforts are currently underway to find novel and more cancer-specific biomarkers that could be detected in a non-invasive way. The analysis of aberrant glycosylation of serum glycoproteins is a way to discover novel diagnostic and prognostic CRC biomarkers. The present study investigated a whole-serum glycome with a panel of 16 different lectins in search for age-independent and CRC-specific glycomarkers using receiver operating characteristic (ROC) curve analyses and glycan heat matrices. Glycosylation changes present in the whole serum were identified, which could lead to the discovery of novel biomarkers for CRC diagnostics. In particular, the change in the bisecting glycans (recognized by Phaseolus vulgaris erythroagglutinin) had the highest discrimination potential for CRC diagnostics in combination with human L selectin providing area under the ROC curve (AUC) of 0.989 (95% CI 0.950-1.000), specificity of 1.000, sensitivity of 0.900, and accuracy of 0.960. We also implemented novel tools for identification of lectins with strong discrimination power.

9.
Bioorg Med Chem ; 39: 116156, 2021 06 01.
Article in English | MEDLINE | ID: mdl-33894508

ABSTRACT

Prostate cancer (PCa) is one of the most common cancer types among men and also acommon cause of death globally. With an increasing incidence, there is aneed for low-cost, reliable biomarkers present in samples, which could be provided non-invasively (without a need to perform prostate biopsy). Glycosylation changes of free-PSA (fPSA) are considered cancer-specific, while the level of different PSA forms can increase under other than cancerous conditions. In the present study, we investigated the role ofN,N-diacetyllactosamine (LacdiNAc) epitope of fPSA (i.e. glycoprofile of fPSA or gPSA) in combination with total-PSA (tPSA), prostate volume, and tPSA density (tPSA level divided by prostate volume i.e. PSAd) as biomarkers for monitoring of PCa development and progression in 105 men. Furthermore, we applied an genetic (evolutionary) algorithm to identify any suspicious individuals in abenign cohort having benign prostatic hyperplasia (BPH). We identified 3 suspicious men originally diagnosed with BPH using gPSA analysis. In thefollow-up we found out that two men should not be considered as BPH patients since multiparametric magnetic resonance imaging (mpMRI) identified one man with clinically significant PCa via Prostate Imaging - Reporting and Data System (PI RADS v2 = 4) and the second man was with High-gradeprostatic intraepithelial neoplasia (HG PIN), commonly described as apre-cancerous stage. Moreover, in the study we described for the first time that changed LacdiNAc on PSA can be applied to identify prostatitis patients and most importantly this is the first study suggesting that changed glycosylation on PSA can be applied to identify castration-resistant prostate cancer (CRPCa) patients.


Subject(s)
Biomarkers, Tumor/blood , Lactose/analogs & derivatives , Prostate-Specific Antigen/blood , Prostatic Hyperplasia/diagnosis , Prostatic Neoplasms, Castration-Resistant/diagnosis , Aged , Cohort Studies , Diagnosis, Differential , Early Detection of Cancer , Enzyme-Linked Immunosorbent Assay , Humans , Lactose/blood , Male , Middle Aged
10.
Processes (Basel) ; 8(5): 580, 2020 May.
Article in English | MEDLINE | ID: mdl-33304843

ABSTRACT

Two-dimensional layered nanomaterial Ti3C2TX (a member of the MXene family) was used to immobilise enzyme sarcosine oxidase to fabricate a nanostructured biosensor. The device was applied for detection of sarcosine, a potential prostate cancer biomarker, in urine for the first time. The morphology and structures of MXene have been characterised by atomic force microscopy (AFM) and scanning electron microscopy (SEM). Electrochemical measurements, SEM and AFM analysis revealed that MXene interfaced with chitosan is an excellent support for enzyme immobilisation to fabricate a sensitive biosensor exhibiting a low detection limit of 18 nM and a linear range up to 7.8 µM. The proposed biosensing method also provides a short response time of 2 s and high recovery index of 102.6% for detection of sarcosine spiked into urine sample in a clinically relevant range.

11.
Cancers (Basel) ; 12(10)2020 Oct 15.
Article in English | MEDLINE | ID: mdl-33076457

ABSTRACT

BACKGROUND: To compare the clinical performance of a new PCa serum biomarker based on fPSA glycoprofiling to fPSA% and PHI. METHODS: Serum samples from men who underwent prostate biopsy due to increased PSA were used. A comparison between two equal groups (with histologically confirmed PCa or benign, non-cancer condition) was used for the clinical validation of a new glycan-based PCa oncomarker. SPSS and R software packages were used for the multiparametric analyses of the receiver operating curve (ROC) and for genetic algorithm metaheuristics. RESULTS: When comparing the non-cancer and PCa cohorts, the combination of four fPSA glycoforms with two clinical parameters (PGI, prostate glycan index (PGI)) showed an area under receiver operating curve (AUC) value of 0.821 (95% CI 0.754-0.890). AUC values were 0.517 for PSA, 0.683 for fPSA%, and 0.737 for PHI. A glycan analysis was also applied to discriminate low-grade tumors (GS = 6) from significant tumors (GS ≥ 7). CONCLUSIONS: Compared to PSA on its own, or fPSA% and the PHI, PGI showed improved discrimination between presence and absence of PCa and in predicting clinically significant PCa. In addition, the use of PGI would help practitioners avoid 63.5% of unnecessary biopsies, while the use of fPSA% and PHI would help avoid 17.5% and 33.3% of biopsies, respectively, while missing four significant tumors (9.5%).

12.
Glycoconj J ; 37(6): 703-711, 2020 12.
Article in English | MEDLINE | ID: mdl-33119808

ABSTRACT

This is the first work focused on glycoprofiling of whole N- and O- glycome using lectins in an array format applied for analysis of serum samples from healthy individuals, benign prostate hyperplasia (BPH) patients, and prostate cancer (PCa) patients. Lectin microarray was prepared using traditional lectins with the incorporation of 2 recombinant bacterial lectins and 3 human lectins (17 lectins in total). Clinical validation of glycans as biomarkers was done in two studies: discrimination of healthy individuals with BPH patients vs. PCa patients (C vs. PCa) and discrimination of healthy individuals vs. BPH and PCa patients (H vs. PCond). Single lectins (17 lectins) and a combination of two lectins (136 binary lectin combinations) were applied in the clinical validation of glycan biomarkers providing 153 AUC values from ROC curves for both studies (C vs. PCa and H vs. PCond). Potential N- and O-glycans as biomarkers were identified and possible carriers of these glycans are shortly discussed.


Subject(s)
Biomarkers, Tumor/blood , Glycoproteins/blood , Lectins/blood , Prostatic Neoplasms/blood , Glycoproteins/genetics , Glycosylation , Humans , Lectins/genetics , Male , Microarray Analysis , Middle Aged , Polysaccharides/blood , Polysaccharides/genetics , Prostatic Neoplasms/genetics , Prostatic Neoplasms/pathology
13.
MethodsX ; 6: 1999-2012, 2019.
Article in English | MEDLINE | ID: mdl-31667097

ABSTRACT

The article describes preparation, characterization and further modification of hybrid magnetic particles (Au nanoshells with a magnetic core (MPs@silica@Au)) by zwitterionic molecules bearing diazonium functional groups. Such hybrid magnetic particles modified by zwitterionic molecules exhibit the following features: •Responsiveness towards external magnetic field applicable for various enrichment strategies due to magnetic core;•Golden outer layer exhibiting free surface plasmons could be used for grafting of zwitterionic molecules via diazonium functionality;•Zwitterionic interface on such particles provides resistivity towards non-specific protein binding; and at the same time such interface was applied for immobilization of antibodies against prostate specific antigen (PSA) applied for selective enrichment of PSA from serum samples with subsequent electrochemical assays. The approach presented here using hybrid magnetic particles can be easily applied for immobilization of antibodies using a highly robust surface patterning protocols i.e. by formation of a self-assembled monolayer with delivery of functional groups on the outer surface of magnetic particles. Hybrid magnetic particles with immobilized antibodies are applied for highly efficient and quick separation of protein of interest i.e. PSA from complex sample. Finally, hybrid magnetic particles with "fished-out" protein molecules could be incubated with lectins to form a sandwich configuration for glycoprofiling of PSA.

14.
Diagnostics (Basel) ; 9(4)2019 Oct 22.
Article in English | MEDLINE | ID: mdl-31652641

ABSTRACT

The U.S. Preventive Services Task Force does not recommend routine screening for testicular cancer (TC) in asymptomatic men, essentially because serological testicular cancer (TC) biomarkers are not reliable. The main reason is that two of the most important TC biomarkers, α-fetoprotein (AFP) and human chorionic gonadotropin (hCG), are not produced solely due to TC. Moreover, up to 40% of patients with TC do not have elevated serological biomarkers, which is why serial imaging with CT is the chief means of monitoring progress. On the other hand, exposure to radiation can lead to an increased risk of secondary malignancies. This review provides the first comprehensive account of the applicability of protein glycoprofiling as a promising biomarker for TC with applications in disease diagnostics, monitoring and recurrence evaluation. The review first deals with the description and classification of TC. Secondly, the limitations of current TC biomarkers such as hCG, AFP and lactate dehydrogenase are provided together with an extensive overview of the glycosylation of hCG and AFP related to TC. The final part of the review summarises the potential of glycan changes on either hCG and AFP as TC biomarkers for diagnostics and prognostics purposes, and for disease recurrence evaluation. Finally, an analysis of glycans in serum and tissues as TC biomarkers is also provided.

15.
Interface Focus ; 9(2): 20180077, 2019 Apr 06.
Article in English | MEDLINE | ID: mdl-30842876

ABSTRACT

The initial part of this review details the controversy behind the use of a serological level of prostate-specific antigen (PSA) for the diagnostics of prostate cancer (PCa). Novel biomarkers are in demand for PCa diagnostics, outperforming traditional PSA tests. The review provides a detailed and comprehensive summary that PSA glycoprofiling can effectively solve this problem, thereby considerably reducing the number of unnecessary biopsies. In addition, PSA glycoprofiling can serve as a prognostic PCa biomarker to identify PCa patients with an aggressive form of PCa, avoiding unnecessary further treatments which are significantly life altering (incontinence or impotence).

16.
Biosens Bioelectron ; 131: 24-29, 2019 Apr 15.
Article in English | MEDLINE | ID: mdl-30798249

ABSTRACT

In this paper several advances were implemented for glycoprofiling of prostate specific antigen (PSA), what can be applied for better prostate cancer (PCa) diagnostics in the future: 1) application of Au nanoshells with a magnetic core (MP@silica@Au); 2) use of surface plasmons of Au nanoshells with a magnetic core for spontaneous immobilization of zwitterionic molecules via diazonium salt grafting; 3) a double anti-fouling strategy with integration of zwitterionic molecules on Au surface and on MP@silica@Au particles was implemented to resist non-specific protein binding; 4) application of anti-PSA antibody modified Au nanoshells with a magnetic core for enrichment of PSA from a complex matrix of a human serum; 5) direct incubation of anti-PSA modified MP@silica@Au with affinity bound PSA to the lectin modified electrode surface. The electrochemical impedance spectroscopy (EIS) signal was enhanced 43 times integrating Au nanoshells with a magnetic core compared to the biosensor without them. This proof-of-concept study shows that the biosensor could detect PSA down to 1.2 fM and at the same time to glycoprofile such low PSA concentration using a lectin patterned biosensor device. The biosensor offers a recovery index of 108%, when serum sample was spiked with a physiological concentration of PSA (3.5 ng mL-1).


Subject(s)
Biosensing Techniques , Dielectric Spectroscopy/methods , Prostate-Specific Antigen/isolation & purification , Prostatic Neoplasms/diagnosis , Antibodies, Immobilized/chemistry , Antibodies, Immobilized/immunology , Gold/chemistry , Humans , Male , Nanoshells/chemistry , Prostate/pathology , Prostate-Specific Antigen/chemistry , Prostatic Neoplasms/pathology
17.
Expert Rev Proteomics ; 16(1): 65-76, 2019 01.
Article in English | MEDLINE | ID: mdl-30451032

ABSTRACT

Introduction: Prostate cancer (PCa) is a life-threatening disease affecting millions of men. The current best PCa biomarker (level of prostate-specific antigen in serum) lacks specificity for PCa diagnostics and this is why novel PCa biomarkers in addition to the conventional ones based on biomolecules such as DNA, RNA and proteins need to be identified. Areas covered: This review details the potential of glycans-based biomarkers to become diagnostic, prognostic, predictive and therapeutic PCa biomarkers with a brief description of the innovative approaches applied to glycan analysis to date. Finally, the review covers the possibility to use exosomes as a rich source of glycans for future innovative and advanced diagnostics of PCa. The review covers updates in the field since 2016. Expert commentary: The summary provided in this review paper suggests that glycan-based biomarkers can offer high-assay accuracy not only for diagnostic purposes but also for monitoring/surveillance of the PCa disease.


Subject(s)
Glycomics/methods , Prostatic Neoplasms/metabolism , Biomarkers, Tumor/metabolism , Exosomes/metabolism , Humans , Lectins/metabolism , Male , Polysaccharides/metabolism
18.
J Fluoresc ; 28(6): 1333-1340, 2018 Nov.
Article in English | MEDLINE | ID: mdl-30218295

ABSTRACT

A novel copolymer poly(thiophene-2,5-diyl-2,5-di-n-octyloxycarbonyl-1,4-phenylene), denoted as P33, is introduced as potential material for photovoltaics, polymer light-emitting diodes, and/or organic transistors. P33 dissolved in chloroform is investigated by steady-state absorption, linear/non-linear fluorescence spectroscopies and time-resolved fluorescence spectroscopy. Molar extinction coefficient, fluorescence quantum yield, and singlet fluorescence lifetime of P33 are determined to be 18,315 M-1 cm-1, 0.4, and 810 ps, respectively. The P33 fluorescence fast components of decay times are 1.2 ps, 2.0 ps, and 0.5 ps for increasing wavelengths of 480 nm, 500 nm, and 520 nm, respectively. The fast component is attributed to a transport of nearly instantaneously formed excitons to localized states known as downhill energy transfer. Additionally multi-photon excited fluorescence is observed for pumping with wavelengths of 800 nm and 1200 nm. Two-photon absorption cross-section is determined to be 6.9 GM. These spectroscopic studies provide basic fluorescence characteristics of the novel thiophene copolymer P33.

19.
Clin Chim Acta ; 481: 49-55, 2018 Jun.
Article in English | MEDLINE | ID: mdl-29486148

ABSTRACT

In this study, one hundred serum samples from healthy people and patients with rheumatoid arthritis (RA) were analyzed. Standard immunoassays for detection of 10 different RA markers and analysis of glycan markers on antibodies in 10 different assay formats with several lectins were applied for each serum sample. A dataset containing 2000 data points was data mined using artificial neural networks (ANN). We identified key RA markers, which can discriminate between healthy people and seropositive RA patients (serum containing autoantibodies) with accuracy of 83.3%. Combination of RA markers with glycan analysis provided much better discrimination accuracy of 92.5%. Immunoassays completely failed to identify seronegative RA patients (serum not containing autoantibodies), while glycan analysis correctly identified 43.8% of these patients. Further, we revealed other critical parameters for successful glycan analysis such as type of a sample, format of analysis and orientation of captured antibodies for glycan analysis.


Subject(s)
Arthritis, Rheumatoid/blood , Artificial Intelligence , Glycomics , Polysaccharides/blood , Rheumatoid Factor/blood , Autoantibodies/blood , Biomarkers/blood , Female , Humans , Male , Middle Aged
20.
Chemphyschem ; 16(11): 2466-73, 2015 Aug 03.
Article in English | MEDLINE | ID: mdl-26033679

ABSTRACT

The solvation and confinement of coumarin C153 within supramolecular host/guest complexes based on ß-cyclodextrin (ß-CD) and 6-deoxy-6-thio-ß-cyclodextrin (ß-CD-SH) in water are studied by fluorescence spectroscopy. For ß-CD/C153, the 1:1 complex is proposed, and for ß-CD-SH/C153 both the 1:1 and 2:1 complexes are believed to be formed. The 2:1 ß-CD-SH/C153 complex has an association constant of 4.2×10(5) M(-1) and a C153 population of 82 %, which are interestingly high values, indicating that the proposed ß-CD-SH dimers structure are connected by covalent disulfide bonds; this is supported by mass spectrometry. Solvation related to fast hydrogen-bond rearrangement as a part of fluorescence relaxation is determined by the ultrafast components of time-resolved spectroscopy to be 3 and 7 ps for the 1:1 ß-CD/C153 and 2:1 ß-CD-SH/C153 complexes, respectively.

SELECTION OF CITATIONS
SEARCH DETAIL
...