Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
1.
Clin Nucl Med ; 48(12): 1064-1065, 2023 Dec 01.
Article in English | MEDLINE | ID: mdl-37934704

ABSTRACT

ABSTRACT: 68Ga-PSMA-11 (68Ga-prostate-specific membrane antigen-11) PET/CT continues to have a great clinical value for staging in prostate cancer. Lymph nodes and bone are the most typical metastatic sites of prostate cancer, whereas liver metastases are rare and usually show focally increased tracer uptake in 68Ga-PSMA-11 PET/CT. Here, we present an 88-year-old man with histologically proven metastatic castration-resistant prostate cancer and extensive PSMA-negative liver metastases identified by 68Ga-PSMA-11 PET/CT. This finding is remarkable because the decreased liver uptake of 68Ga-PSMA-11 may resemble a primary hepatic tumor.


Subject(s)
Liver Neoplasms , Prostatic Neoplasms , Male , Humans , Aged, 80 and over , Positron Emission Tomography Computed Tomography , Gallium Radioisotopes , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/pathology , Liver Neoplasms/diagnostic imaging , Edetic Acid
2.
Eur J Radiol ; 165: 110931, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37399666

ABSTRACT

PURPOSE: To investigate whether CT texture analysis allows differentiation between adenocarcinomas, squamous cell carcinomas, carcinoids, small cell lung cancers and organizing pneumonia and between carcinomas and neuroendocrine tumors. METHOD: This retrospective study included patients 133 patients (30 patients with organizing pneumonia, 30 patients with adenocarcinoma, 30 patients with squamous cell carcinoma, 23 patients with small cell lung cancer, 20 patients with carcinoid), who underwent CT-guided biopsy of the lung and had a corresponding histopathologic diagnosis. Pulmonary lesions were segmented in consensus by two radiologists with and without a threshold of -50HU in three dimensions. Groupwise comparisons were performed to assess for differences between all five above-listed entities and between carcinomas and neuroendocrine tumors. RESULTS: Pairwise comparisons of the five entities revealed 53 statistically significant texture features when using no HU-threshold and 6 statistically significant features with a threshold of -50HU. The largest AUC (0.818 [95%CI 0.706-0.930]) was found for the feature wavelet-HHH_glszm_SmallAreaEmphasis for discrimination of carcinoid from the other entities when using no HU-threshold. In differentiating neuroendocrine tumors from carcinomas, 173 parameters proved statistically significant when using no HU threshold versus 52 parameters when using a -50HU-threshold. The largest AUC (0.810 [95%CI 0.728-0,893]) was found for the parameter original_glcm_Correlation for discrimination of neuroendocrine tumors from carcinomas when using no HU-threshold. CONCLUSIONS: CT texture analysis revealed features that differed significantly between malignant pulmonary lesions and organizing pneumonia and between carcinomas and neuroendocrine tumors of the lung. Applying a HU-threshold for segmentation substantially influenced the results of texture analysis.


Subject(s)
Adenocarcinoma , Carcinoid Tumor , Carcinoma, Neuroendocrine , Carcinoma, Squamous Cell , Lung Neoplasms , Neuroendocrine Tumors , Organizing Pneumonia , Pneumonia , Humans , Neuroendocrine Tumors/diagnostic imaging , Neuroendocrine Tumors/pathology , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/pathology , Retrospective Studies , Lung/pathology , Adenocarcinoma/pathology , Carcinoid Tumor/pathology , Carcinoma, Squamous Cell/pathology , Tomography, X-Ray Computed/methods , Carcinoma, Neuroendocrine/pathology , Cell Differentiation
3.
Eur Radiol ; 33(5): 3064-3071, 2023 May.
Article in English | MEDLINE | ID: mdl-36947188

ABSTRACT

OBJECTIVE: Reproducibility problems are a known limitation of radiomics. The segmentation of the target lesion plays a critical role in texture analysis variability. This study's aim was to compare the interobserver reliability of manual 2D vs. 3D lung lesion segmentation with and without pre-definition of the volume using a threshold of - 50 HU. METHODS: Seventy-five patients with histopathologically proven lung lesions (15 patients each with adenocarcinoma, squamous cell carcinoma, small cell lung cancer, carcinoid, and organizing pneumonia) who underwent an unenhanced CT scan of the chest were included. Three radiologists independently segmented each lesion manually in 3D and 2D with and without pre-segmentation volume definition by a HU threshold, and shape parameters and original, Laplacian of Gaussian-filtered, and wavelet-based texture features were derived. To assess interobserver reliability and identify the most robust texture features, intraclass correlation coefficients (ICCs) for different segmentation settings were calculated. RESULTS: Shape parameters had high reliability (64-79% had excellent and good ICCs). Texture features had weak reliability levels, with the highest ICCs (38% excellent or good) found for original features in 3D segmentation without the use of a HU threshold. A small proportion (4.3-11.5%) of texture features had excellent or good ICC values at all segmentation settings. CONCLUSION: Interobserver reliability of texture features from CT scans of a heterogeneous collection of manually segmented lung lesions was low with a small proportion of features demonstrating high reliability independent of the segmentation settings. These results indicate a limited applicability of texture analysis and the need to define robust texture features in patients with lung lesions. KEY POINTS: • Our study showed a low reproducibility of texture features when 3 radiologists independently segmented lung lesions in CT images, which highlights a serious limitation of texture analysis. • Interobserver reliability of texture features was low regardless of whether the lesion was segmented in 2D and 3D with or without a HU threshold. • In contrast to texture features, shape parameters showed a high interobserver reliability when lesions were segmented in 2D vs. 3D with and without a HU threshold of - 50.


Subject(s)
Adenocarcinoma , Lung Neoplasms , Humans , Reproducibility of Results , Adenocarcinoma/diagnostic imaging , Tomography, X-Ray Computed/methods , Lung Neoplasms/diagnostic imaging , Lung/diagnostic imaging
5.
Abdom Radiol (NY) ; 47(12): 4151-4159, 2022 12.
Article in English | MEDLINE | ID: mdl-36104481

ABSTRACT

PURPOSE: To evaluate the utility of non-contrast-enhanced CT texture analysis (CTTA) for predicting the histopathological differentiation of pancreatic ductal adenocarcinomas (PDAC) and to compare non-contrast-enhanced CTTA texture features between primary PDAC and hepatic metastases of PDAC. METHODS: This retrospective study included 120 patients with histopathologically confirmed PDAC. Sixty-five patients underwent CT-guided biopsy of primary PDAC, while 55 patients underwent CT-guided biopsy of hepatic PDAC metastasis. All lesions were segmented in non-contrast-enhanced CT scans for CTTA based on histogram analysis, co-occurrence matrix, and run-length matrix. Statistical analysis was conducted for 372 texture features using Mann-Whitney U test, Bonferroni-Holm correction, and receiver operating characteristic (ROC) analysis. A p value < 0.05 was considered statistically significant. RESULTS: Three features were identified that differed significantly between histopathological G2 and G3 primary tumors. Of these, "low gray-level zone emphasis" yielded the largest AUC (0.87 ± 0.04), reaching a sensitivity and specificity of 0.76 and 0.83, respectively, when a cut-off value of 0.482 was applied. Fifty-four features differed significantly between primary and hepatic metastatic PDAC. CONCLUSION: Non-contrast-enhanced CTTA of PDAC identified differences in texture features between primary G2 and G3 tumors that could be used for non-invasive tumor assessment. Extensive differences between the features of primary and metastatic PDAC on CTTA suggest differences in tumor microenvironment.


Subject(s)
Adenocarcinoma , Carcinoma, Pancreatic Ductal , Liver Neoplasms , Pancreatic Neoplasms , Humans , Retrospective Studies , Tomography, X-Ray Computed , Tumor Microenvironment , Pancreatic Neoplasms
6.
J Thorac Imaging ; 37(5): 323-330, 2022 Sep 01.
Article in English | MEDLINE | ID: mdl-35797627

ABSTRACT

PURPOSE: Computed tomography pulmonary angiography (CT-PA) is frequently used in the diagnostic workup of pulmonary embolism (PE), even in highly radiosensitive patient populations. This study aims to assess CT-PA with reduced z -axis coverage (compared with a standard scan range covering the entire lung) for its sensitivity for detecting PE and its potential to reduce the radiation dose. MATERIALS AND METHODS: We retrospectively analyzed 602 consecutive CT-PA scans with definite or possible PE reported. A reduced scan range was defined based on the topogram, where the cranial slice was set at the top of the aortic arch and the caudal slice at the top of the lower hemidiaphragm. Locations of emboli in relation to the reduced scan range were recorded. RESULTS: We included 513 CT-PA scans with definite acute PE in statistical analysis. Patients' median age was 66 (52 to 77) years, 46% were female. Median dose length product was 270.8 (111.3 to 503.9) mGy*cm. Comparing the original and reduced scan ranges, the mean scan length was significantly reduced by 48.0±8.6% (26.8±3.0 vs. 13.9±2.6 cm, P <0.001). Single emboli outside the reduced range in addition to emboli within were found in 15 scans (2.9%), while only 1 scan (0.2%) had an embolus outside the reduced range and none within it. The resulting sensitivity of CT-PA with reduced scan range was 99.81% (95% confidence interval: 98.74%-99.99%) for detecting any PE. CONCLUSION: A reduced scan length in CT-PA, as defined above, would substantially decrease radiation dose while maintaining diagnostic accuracy for detecting PE.


Subject(s)
Angiography , Pulmonary Embolism , Aged , Angiography/methods , Computed Tomography Angiography , Female , Humans , Lung , Male , Pulmonary Embolism/diagnostic imaging , Radiation Dosage , Retrospective Studies , Tomography, X-Ray Computed/methods
9.
J Plast Reconstr Aesthet Surg ; 75(1): 160-172, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34635456

ABSTRACT

BACKGROUND: With the experience-based hypothesis of low donor site morbidity (DSM) for free flaps from the distal femur, this cohort study aimed to evaluate the DSM according to objective and reproducible criteria. METHODS: One hundred and fifty-six patients who had a flap harvest from either the medial or lateral femoral condyle region between 2005 and 2017 were included. A retrospective chart review was performed for all patients. In total, 97 patients were available for a follow-up examination. Outcomes were assessed according to objective (Knee Society Score; Larson Knee Score; OAK Score; 0-100 points), patient-reported (IKDC Score; KOOS Score; 0-100 points), and radiologic criteria (Kellgren and Lawrence Score; MRI Osteoarthritis Knee Score). RESULTS: The median follow-up time was 1529 days (range: 248-4,810). The mean Knee Society Score (94.8 ± 10.1), Larson Knee Score (94.5 ± 10.1), and OAK Score (95.5 ± 6.6) showed nearly unimpaired knee function. The overall patient-reported DSM was low (IKDC Score: 86.7 ± 17.4; KOOS Score: 89.3 ± 17.1). Osteochondral (OC) flaps had a significantly higher DSM, regardless of the donor site. Bone flaps did not show any relevant radiologic morbidity in the Kellgren and Lawrence Score. Besides the procedure-associated cartilage lesions at the OC donor sites, MRI Osteoarthritis Knee Score did not show any significant presence of further knee pathologies in the bilateral MRI Scans. The obvious cartilage lesions did not have a relevant impact on the knee function of most patients. CONCLUSION: The DSM for bone and soft-tissue flaps from the femoral condyle region is negligible. OC flaps are associated with a significantly higher DSM, although a clinically relevant impact on knee function was not evident in the majority of patients.


Subject(s)
Cartilage, Articular , Free Tissue Flaps , Intra-Articular Fractures , Osteoarthritis , Cartilage, Articular/surgery , Cohort Studies , Femur , Free Tissue Flaps/adverse effects , Humans , Knee Joint/surgery , Morbidity , Patient Reported Outcome Measures , Retrospective Studies
10.
Visc Med ; 37(4): 302-314, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34540947

ABSTRACT

INTRODUCTION: Liver transplantation (LT) is today's standard treatment for both end-stage liver disease and tumors; however, suitable grafts for LT are a scarce resource and outcome after LT is highly dependent on its underlying indication. Thus, patients must be carefully selected to optimize the number of life years gained per graft. This comprehensive and systematic review critically reflects the most recently published oncological outcome data after LT in malignancies based on the preoperative radiological findings. METHODS: A systematic literature search was conducted to detect preferentially most recent high-volume series or large database analysis on oncological outcomes after LT for both primary liver cancer and liver metastases between January 1, 2019, and November 14, 2020. A comprehensive review on the radiological assessment of the reviewed liver malignancies is included and its preoperative value for an outcome-driven indication reflected. RESULTS: Twenty most recent high-volume or relevant studies including a total number of 2,521 patients were identified including 4, 4, 4, 4, 3, and 1 publications on oncological outcome after LT for hepatocellular carcinoma, cholangiocellular carcinoma, hepatic epitheloid hemangioendothelioma, hepatoblastoma, and both metastatic neuroendocrine tumors and colorectal cancer, respectively. The overall survival is comparable to patients without tumors if patients with malignancies are well selected for LT; however, this is highly dependent on tumor entity, tumor stage, and both neoadjuvant and concomitant treatment. DISCUSSION/CONCLUSION: LT is a promising option for better survival in patients with malignant liver tumors in selected patients; however, the indication must be critically discussed prior to LT in every single case in the context of organ shortage.

11.
Eur J Radiol ; 141: 109778, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34174486

ABSTRACT

PURPOSE: To assess correlations of lean body weight (LBW) calculated with various formulas, total body weight (TBW), body height (BH), body mass index (BMI), body surface area (BSA) and fat-free mass (FFM) with vascular and parenchymal enhancement in multiphasic CT of the liver. METHOD: Thirty consecutive patients underwent multiphasic CT of the liver using constant iodine dose and flow rate. Contrast enhancement of aorta, portal vein and liver was calculated by measuring mean vascular and parenchymal attenuation in pre-contrast and post-contrast phases. Correlations of TBW, BH, BMI, BSA, FFM, and LBW (calculated with formulas of Boer, Hume, James and Green&Duffull) with enhancement were tested using Spearman's correlation coefficient. The method of Fieller et al. was used to calculate 95 % confidence intervals. A p-value ≤ 0.05 was considered statistically significant. RESULTS: Aortal enhancement correlated strongly with TBW, BSA, LBWBoer and LBWHume and moderately with BH, BMI, FFM, LBWJames and LBWGreen&Duffull. Liver enhancement in the late arterial phase correlated moderately with TBW, FFM, LBWBoer, LBWHume and LBWGreen&Duffull and weakly with BSA. Liver enhancement in the portal venous phase correlated strongly with TBW, BSA, FFM, LBWBoer, LBWHume and LBWGreen&Duffull, whereby overlap of the 95 % CI graphs demonstrated that the differences in the correlation coefficients were not statistically significant. Liver enhancement in the delayed phase correlated moderately with BH but did not correlate significantly with any other parameter. CONCLUSION: Regardless of the form used for calculation, LBW did not correlate statistically significantly stronger than TBW with vascular or parenchymal enhancement of the liver.


Subject(s)
Benchmarking , Contrast Media , Body Weight , Humans , Liver/diagnostic imaging , Tomography, X-Ray Computed
12.
Rofo ; 193(5): 584-585, 2021 May.
Article in German | MEDLINE | ID: mdl-32818971

Subject(s)
Bezoars , Humans , Syndrome
SELECTION OF CITATIONS
SEARCH DETAIL
...