Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
ACS Appl Mater Interfaces ; 16(24): 31473-31479, 2024 Jun 19.
Article in English | MEDLINE | ID: mdl-38850243

ABSTRACT

Scalable micro graphene Hall sensors (µGHSs) hold tremendous potential for highly sensitive and label-free biomagnetic sensing in physiological solutions. To enhance the performance of these devices, it is crucial to optimize frequency-dependent flicker noise to reduce the limit of detection (LOD), but it remains a great challenge due to the large contact resistance at the graphene-metal contact. Here we present a surface modification strategy employing persistent carbene on gold electrodes to reduce the contact resistivity by a factor of 25, greatly diminishing µGHS flicker noise by a factor of 1000 to 3.13 × 10-14 V2/Hz while simultaneously lowering the magnetic LOD SB1/2 to 1440 nT/Hz1/2 at 1 kHz under a 100 µA bias current. To the best of our knowledge, this represents the lowest SB1/2 reported for scalable µGHSs fabricated through wafer-scale photolithography. The reduction in contact noise is attributed to the π-π stacking interaction between the graphene and the benzene rings of persistent carbene, as well as the decrease in the work function of gold as confirmed by Kelvin Probe Force Microscopy. By incorporating a microcoil into the µGHS, we have demonstrated the real-time detection of superparamagnetic nanoparticles (SNPs), achieving a remarkable LOD of ∼528 µg/L. This advancement holds great potential for the label-free detection of magnetic biomarkers, e.g., ferritin, for the early diagnosis of diseases associated with iron overload, such as hereditary hemochromatosis (HHC).

2.
J Microbiol Biotechnol ; 30(8): 1116-1123, 2020 Aug 28.
Article in English | MEDLINE | ID: mdl-32423187

ABSTRACT

Velvet antler (VA) is a historically traditional medicinal supplement and is well known in Asian countries for its pharmaceutical and health benefits. The objectives for this study were to optimize the hot water extraction (HWE) of VA for the Korean VA industry, and to determine the most effective pretreatment method among microwave (MW), ultrasonication (US), and enzymatic (EZ) techniques. Using response surface methodology, optimum extraction temperatures and times were determined by central composite design configuration based on extraction yield and sialic acid content. Various quality parameters of VA extract including yield, soluble solid, protein, and sialic acid contents were also compared with the conjunction of HWE and pretreatment. The yield and sialic acid content of VA extract were determined to be 40% and 0.73 mg/g, respectively, under an optimum temperature of 100°C at 24 h of extraction time. The yields from VA extracts pretreated with MW, US, and EZ were 17.42%, 19.73%, and 29.15%, respectively. Among the tested commercial enzymes, pepsin was the most effective proteolytic enzyme and led to the highest yield (47.65%), soluble solids (4.03 °brix), protein (1.12 mg/ml), and sialic acid (3.04 mg/ml) contents from VA extract.


Subject(s)
Antlers/chemistry , Medicine, Traditional , Water/chemistry , Animals , Complex Mixtures , Deer , Hot Temperature , N-Acetylneuraminic Acid , Republic of Korea , Temperature
3.
Opt Express ; 16(8): 5299-304, 2008 Apr 14.
Article in English | MEDLINE | ID: mdl-18542631

ABSTRACT

We demonstrate a room-temperature operation of the near-infrared femtosecond optical parametric oscillator based on MgO-doped stoichiometric periodically-poled lithium niobate, which is synchronously pumped by a Kerr-lens mode-locked Ti:sapphire laser. Wide tunability in the range from 0.98 microm to 1.50 microm was enabled for a single set of cavity mirrors by incorporating a BK7 window as an output coupler. For the output coupling ratio of 3.7%, the threshold pumping power of 460 mW and the slope power conversion efficiency of 37% were achieved. By controlling dispersion values with intra-cavity prisms, femtosecond pulses as short as 66 fs could be obtained.


Subject(s)
Amplifiers, Electronic , Computer-Aided Design , Lasers , Magnesium Oxide/chemistry , Models, Theoretical , Niobium/chemistry , Oscillometry/instrumentation , Oxides/chemistry , Computer Simulation , Equipment Design , Equipment Failure Analysis , Light , Magnesium Oxide/radiation effects , Niobium/radiation effects , Oxides/radiation effects
SELECTION OF CITATIONS
SEARCH DETAIL
...