Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add more filters










Publication year range
1.
J Biomater Appl ; 33(9): 1232-1241, 2019 04.
Article in English | MEDLINE | ID: mdl-30776991

ABSTRACT

Everolimus inhibits stent restenosis and the WKYMV (fluorescein isothiocyanate) peptide promotes endothelial homing. Dextran is a natural polymer that is widely used as a pharmaceutical agent. The purpose of this study was to develop a double-drug-coated stent using a bidirectional coating system and to examine the surface shape with in vitro experiments. Stent length was 16 mm and strut thickness was 70 µm (Chonnam National University Hospital Tiger stent). Optical and scanning electron microscopy showed good coating without cracks or bubbles. Fluorescein isothiocyanate-peptide was dip-coated on the lumen and the abluminal surface was coated with everolimus and dextran. Stents were coated with dextran, everolimus, or everolimus-dextran. The radial force and flexibility were measured to determine the mechanical properties. Contact angle testing was performed in all groups. Dextran and peptide as hydrophilic substances and everolimus as a hydrophobic substance were each coated on cover glasses (cobalt-chromium). A10 and human umbilical vein endothelial cells were used in the experiments. Water and dimethyl sulfoxide served as a control, and three drug groups were tested: peptide-everolimus, everolimus-dextran, and peptide-everolimus-dextran. Immunocytochemistry was performed to assess cell adhesion. Light intensity was plotted according to the average on nuclear staining. Experiments were conducted using 5-bromo-2'-deoxyuridine to investigate A10 and human umbilical vein endothelial cell proliferation. Cell adhesion and proliferation of peptide-everolimus-dextran were inhibited at A10, and human umbilical vein endothelial cell was found to proliferate with cell adhesion. On conclusion, dextran and peptide-everolimus bidirectional stent is effective in re-endothelialization and inhibition of cell proliferation.


Subject(s)
Dextrans/administration & dosage , Drug-Eluting Stents , Everolimus/administration & dosage , Oligopeptides/administration & dosage , Animals , Cell Adhesion/drug effects , Cell Line , Cell Proliferation/drug effects , Dextrans/chemistry , Dextrans/pharmacology , Drug Delivery Systems , Everolimus/chemistry , Everolimus/pharmacology , Human Umbilical Vein Endothelial Cells , Humans , Hydrophobic and Hydrophilic Interactions , Oligopeptides/chemistry , Oligopeptides/pharmacology , Rats
2.
Mater Sci Eng C Mater Biol Appl ; 91: 615-623, 2018 Oct 01.
Article in English | MEDLINE | ID: mdl-30033294

ABSTRACT

Inflammation and thrombosis are linked to the use of polymer-based drug-eluting stents (DES). The aim of this study was to develop a polymer-free everolimus (EVL)-eluting stent using nitrogen-doped titanium dioxide (N-TiO2) and verify its efficacy by in vitro and in vivo assessment in a porcine coronary model. Various analytical approaches such as scanning electron microscopy and atomic force microscopy, electron spectroscopy, Fourier transform infrared spectrometry and contact angle measurement were employed for the characterization. As a part of biocompatibility assessment, platelet adhesion and smooth muscle cell (SMC) proliferation were examined. Bare metal stent (BMS), N-TiO2 stent, everolimus-eluting N-TiO2 (N-TiO2-EVL) stent, and commercialized EVL-eluting stent (EES) were randomly placed in forty coronary arteries in twenty pigs. After four weeks of implantation, the stents were subjected to histological and quantitative analysis. The N-TiO2 film used in this study was well coated without any cracks or peeling. Surface hydrophilicity (88.8% of angle decrement) could be associated with the decrease in surface roughness post N-TiO2 deposition (37.0%). The platelet adhesion on the N-TiO2 surfaces was less than that on the BMS surface. The proliferation of SMC was suppressed in the N-TiO2-EVL group (30.2%) but not in the BMS group. In the animal study, the percent area restenosis was significantly decreased in the N-TiO2-EVL group compared to that in the BMS group. The results (BMS; 47.0 ±â€¯11.00%, N-TiO2-EVL; 31.7 ±â€¯10.50%, and EES; 29.1 ±â€¯11.21%, n = 10, p < 0.05) were almost at par with those of the commercialized EVL-eluting stent. The introduction of N-TiO2 deposition during fabrication of polymer-free DES may be an efficient accessorial process for preventing in-stent restenosis and thrombosis.


Subject(s)
Drug-Eluting Stents , Everolimus/pharmacology , Nitrogen/chemistry , Polymers/chemistry , Titanium/chemistry , Animals , Cell Proliferation/drug effects , Coronary Restenosis/pathology , Disease Models, Animal , Myocytes, Smooth Muscle/cytology , Myocytes, Smooth Muscle/drug effects , Platelet Adhesiveness/drug effects , Platelet Aggregation/drug effects , Spectroscopy, Fourier Transform Infrared , Surface Properties , Sus scrofa , Tomography, Optical Coherence
3.
J Biomater Appl ; 32(8): 1083-1089, 2018 03.
Article in English | MEDLINE | ID: mdl-29256322

ABSTRACT

The first two authors contributed equally to this study. Bioactivity and cell adhesion properties are major factors for fabricating medical devices such as coronary stents. The aim of this study was to evaluate the advantages of atmospheric-pressure plasma jet in enhancing the biocompatibility and endothelial cell-favorites. The experimental objects were divided into before and after atmospheric-pressure plasma jet treatment with the ratio of nitrogen:argon = 3:1, which is similar to air. The treated surfaces were basically characterized by means of a contact angle analyzer for the activation property on their surfaces. The effect of atmospheric-pressure plasma jet on cellular response was examined by endothelial cell adhesion and XTT analysis. It was difficult to detect any changeable morphology after atmospheric-pressure plasma jet treatment on the surface. The roughness was increased after atmospheric-pressure plasma jet treatment compared to nonatmospheric-pressure plasma jet treatment (86.781 and 7.964 nm, respectively). The X-ray photoelectron spectroscopy results showed that the surface concentration of the C-O groups increased slightly from 6% to 8% after plasma activation. The contact angle dramatically decreased in the atmospheric-pressure plasma jet treated group (22.6 ± 15.26°) compared to the nonatmospheric-pressure plasma jet treated group (72.4 ± 15.26°) ( n = 10, p < 0.05). The effect of the increment in hydrophilicity due to the atmospheric-pressure plasma jet on endothelial cell migration and proliferation was 85.2% ± 12.01% and 34.2% ± 2.68%, respectively, at 7 days, compared to the nonatmospheric-pressure plasma jet treated group (58.2% ± 11.44% in migration, n = 10, p < 0.05). Taken together, the stent surface could easily obtain a hydrophilic property by the atmospheric-pressure plasma jet method. Moreover, the atmospheric-pressure plasma jet might affect re-endothelialization after stenting.


Subject(s)
Biocompatible Materials/chemistry , Endothelial Cells/cytology , Plasma Gases/chemistry , Stents , Atmospheric Pressure , Cell Movement , Cell Proliferation , Human Umbilical Vein Endothelial Cells , Humans , Hydrophobic and Hydrophilic Interactions , Surface Properties
4.
J Biomed Mater Res B Appl Biomater ; 106(4): 1486-1495, 2018 05.
Article in English | MEDLINE | ID: mdl-28691192

ABSTRACT

The aim of this study was to evaluate the effects of bilirubin- and/or everolimus (EVL)-coated stents to prevent arterial neointimal hyperplasia and inflammation in vitro and in vivo. The stents were prepared by spray coating bare metal stents (BMS) with bilirubin and/or EVL. Study groups were divided into (1) BMS, (2) bilirubin-coated stents (BES), (3) commercialized stents (Synergy™; EES), and (4) bilirubin/EVL-coated stents (B-EES). The coating thickness and drug release rates were comparable to previous reports (i.e., <4 µm thickness and 50% drug release in 7 days). Smooth muscle cell migration was inhibited in both EVL-containing groups (20.5 ± 3.80% in EES and 18.4 ± 2.55% in B-EES) compared to the non-EVL-containing groups (78.0 ± 6.41% in BMS and 76.1 ± 4.88% in BES) (n = 10, p < 0.05). Stents were randomly implanted to 40 coronary arteries in 20 pigs and subjected to various analyses after 4 weeks of implantation. As results, the inflammation score was dramatically increased in the EES group (2.1 ± 0.42) compared to that of the other groups (1.5 ± 0.55, 1.3 ± 0.23, and 1.5 ± 0.27 for BMS, BES, and B-EES, respectively, n = 10, p < 0.05). Immunofluorescence analysis revealed that inflammation was prevented in the bilirubin-containing groups (BES and B-EES). However, the percent area of restenosis was decreased in the EVL-containing groups (20.5 ± 4.11% for EES and 18.4 ± 3.61% for B-EES) compared to the non-EVL-containing groups (32.3 ± 6.41% for BMS and 29.6 ± 5.95% for BES, n = 10, p < 0.05). The percent areas of restenosis determined by histopathology, optical coherence tomography, and micro-computed tomography were consistent. In addition, the stent was barely covered in the EES and B-EES groups at 4 weeks postimplantation. These dual drug-coated stents may be especially beneficial to patients who have an increased risk of inflammation. These stents have great potential for use in cardiovascular applications. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 1486-1495, 2018.


Subject(s)
Bilirubin , Coronary Vessels , Drug-Eluting Stents , Graft Occlusion, Vascular , Muscle, Smooth, Vascular/metabolism , Myocytes, Smooth Muscle/metabolism , Animals , Bilirubin/chemistry , Bilirubin/pharmacology , Coronary Vessels/diagnostic imaging , Coronary Vessels/metabolism , Coronary Vessels/surgery , Graft Occlusion, Vascular/diagnostic imaging , Graft Occlusion, Vascular/metabolism , Graft Occlusion, Vascular/prevention & control , Male , Random Allocation , Swine , Tomography, Optical Coherence
5.
J Biomater Appl ; 31(10): 1337-1345, 2017 05.
Article in English | MEDLINE | ID: mdl-28436251

ABSTRACT

The aim of this study was to evaluate the inhibitory effect of sirolimus coating on the occurrence of restenosis and thrombosis with heparinized stents. Heparin and dopamine were conjugated by chemical bonding and anchored on the stent surface by a mussel-inspired adhesion mechanism. Subsequently, sirolimus was coated with poly lactic-glycolic acid on the heparinized stent surface. The heparin was well attached to the surface, and the surface was smooth after sirolimus coating. The smoothness of the surface was maintained after expansion of the stent. The amount of sirolimus released from the stent was 67.3% ± 4.55% within 7 days, followed by continual release up to day 28. The proliferation of smooth muscle cells was successfully arrested (51.3% ± 2.25% at 7 days of culture) by sirolimus released from the stent. Platelet adhesion was clearly prevented in the heparin-coated group (78.0 ± 8.00/1.8 cm2) compared to that in the heparin noncoated group (5.0 ± 1.00/1.8 cm2). Animal studies showed that the heparin and sirolimus-coated stent group had no obvious inflammatory response and no change in the fibrin score compared to those in the other groups. However, restenosis clearly decreased in the heparin and sirolimus-coated group (12.3% ± 3.54%) compared to the bare-metal stent group (27.5% ± 8.52%) and the heparin-coated group (25.3% ± 11.79%). These results suggest that heparinized surface-based sirolimus coating may be a useful approach for the prevention of restenosis and stent thrombosis.


Subject(s)
Coronary Restenosis/prevention & control , Drug-Eluting Stents , Heparin/chemistry , Sirolimus/chemistry , Thrombosis/prevention & control , Animals , Cell Adhesion , Cell Line , Cell Proliferation , Cell Survival , Coated Materials, Biocompatible , Drug Delivery Systems , Drug Liberation , Humans , Iliac Artery/surgery , Kinetics , Platelet Adhesiveness , Rabbits , Rats , Sirolimus/metabolism , Sirolimus/pharmacology , Surface Properties
6.
J Biomed Mater Res A ; 105(1): 301-310, 2017 01.
Article in English | MEDLINE | ID: mdl-27615559

ABSTRACT

The aim of this study was to compare dextran and Poly(l-lactide) (PLLA) polymer stent coatings as mediators for sirolimus (SRL) drug elution in a porcine coronary model. The bare metal stent (BMS) surface was first coated with a layer of SRL and then either dextran (DSS, a natural polymer) or PLA (PSS, a synthetic polymer). The release velocity of SRL was slightly faster in DSS than PSS over the first 7 days (78.5% and 62.3%, respectively, n = 10, p < 0.05) and continued to 28 days in both groups. The contact angle was dramatically decreased in DSS (38.7° ± 1.24) compared to BMS and PSS groups (72.7° ± 5.32 and 81.1º ± 1.70, respectively, n = 10, p < 0.05). Smooth muscle cell migration was arrested in both the DSS and PSS-treated groups compared to that in the nontreated group (4.2% ± 0.31, 5.8% ± 0.60, 80.0% ± 4.4, respectively, n = 10, p < 0.05). In the animal study, there were no significant differences in the injury score, the internal elastic lamina, and the lumen area among the groups. However, percent area stenosis was significantly decreased in the SRL-containing group (27.5% ± 2.52 in DSS and 27.9% ± 3.30 in PSS) compared to BMS (35.9% ± 3.51, p < 0.05). The fibrin score was higher in the PSS (2.9 ± 0.31) than BMS (2.1 ± 0.12) and DSS (2.5 ± 0.66). The inflammation score in the DSS (0.7 ± 0.21) was similar to that in the BMS (0.7 ± 0.12), which was dramatically lower than that PSS (1.5 ± 0.18, p < 0.005). Immunofluorescence analysis revealed that endothelialization was increased and inflammation prevented in the DSS. These results suggest that dextran may be useful for the fabrication of drug eluting stent as an alternative existing synthetic polymer. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 301-310, 2017.


Subject(s)
Dextrans/chemistry , Drug-Eluting Stents , Models, Cardiovascular , Muscle, Smooth, Vascular/metabolism , Myocytes, Smooth Muscle/metabolism , Polyesters/chemistry , Sirolimus , Animals , Cells, Cultured , Male , Muscle, Smooth, Vascular/cytology , Myocytes, Smooth Muscle/cytology , Sirolimus/chemistry , Sirolimus/pharmacology , Swine
7.
J Mater Sci Mater Med ; 27(4): 66, 2016 Apr.
Article in English | MEDLINE | ID: mdl-26886814

ABSTRACT

The aim of this study was to evaluate antiproliferative sirolimus- and antioxidative alpha-lipoic acid (ALA)-eluting stents using biodegradable polymer [poly-L-lactic acid (PLA)] in a porcine coronary overstretch restenosis model. Forty coronary arteries of 20 pigs were randomized into four groups in which the coronary arteries had a bare metal stent (BMS, n = 10), ALA-eluting stent with PLA (AES, n = 10), sirolimus-eluting stent with PLA (SES, n = 10), or sirolimus- and ALA-eluting stent with PLA (SAS, n = 10). A histopathological analysis was performed 28 days after the stenting. The ALA and sirolimus released slowly over 30 days. There were no significant differences between groups in the injury or inflammation score; however, there were significant differences in the percent area of stenosis (56.2 ± 11.78% in BMS vs. 51.5 ± 12.20% in AES vs. 34.7 ± 7.23% in SES vs. 28.7 ± 7.30% in SAS, P < 0.0001) and fibrin score [1.0 (range 1.0-1.0) in BMS vs. 1.0 (range 1.0-1.0) in AES vs. 2.0 (range 2.0-2.0) in SES vs. 2.0 (range 2.0-2.0) in SAS, P < 0.0001] between the four groups. The percent area of stenosis based on micro-computed tomography corresponded with the restenosis rates based on histopathological stenosis in different proportions in the four groups (54.8 ± 7.88% in BMS vs. 50.4 ± 14.87% in AES vs. 34.5 ± 7.22% in SES vs. 28.9 ± 7.22% in SAS, P < 0.05). SAS showed a better neointimal inhibitory effect than BMS, AES, and SES at 1 month after stenting in a porcine coronary restenosis model. Therefore, SAS with PLA can be a useful drug combination for coronary stent coating to suppress neointimal hyperplasia.


Subject(s)
Coronary Restenosis/therapy , Drug-Eluting Stents , Sirolimus/pharmacology , Thioctic Acid/pharmacology , Animals , Fibroblasts , Rats , Sirolimus/chemistry , Swine , Thioctic Acid/chemistry , Treatment Outcome
8.
J Biomater Appl ; 31(1): 36-44, 2016 07.
Article in English | MEDLINE | ID: mdl-26873634

ABSTRACT

Glucocorticoids are powerful anti-inflammatory, immunosuppressive, and anti-proliferative agents. The aim of this study was to evaluate the effectiveness of a prednisolone- (PDScs) and sirolimus-coated stent (SRLcs) in preventing artery vessel neointimal hyperplasia and inflammatory reactions in vitro and in vivo. PDS, a synthetic glucocorticoid, is a derivative of cortisol, which is used to treat a variety of inflammatory and autoimmune conditions. The stents were fabricated with PDS, SRL, or both agents using a layer-by-layer coating system (designated as PDScs, SRLcs, and PDSRLcs, respectively). The surface morphology of the PDScs showed an evenly dispersed and roughened shape, which was smoothened by the SRL coating. Half of the total drug amounts were released within seven days, followed by an additional release, which continued for up to 28 days. The proliferation of smooth muscle cells was inhibited in the SRLcs group (31.5 ± 4.08%), and this effect was enhanced by PDS addition (PDSRLcs, 46.8 ± 8.11%). Consistently, in the animal study, the restenosis rate was inhibited by the SRLcs and PDSRLcs (18.5 ± 6.23% and 14.5 ± 3.55%, respectively). Especially, fibrin expression and inflammation were suppressed in the PDS-containing group (PDScs, 0.6 ± 0.12 and 1.4 ± 0.33; PDSRLcs, 0.7 ± 0.48 and 1.7 ± 0.12, respectively) compared to PDS non-containing groups (BMS, 1.1 ± 0.12, and 1.8 ± 0.55; SRLcs, 1.6 ± 0.32 and 2.0 ± 0.62, respectively). Moreover, re-endothelialization was enhanced in the PDScs group as determined using immunohistochemistry with a cluster of differentiation (CD)-31 antibodies. These results suggest that the inhibitory effect of SRLcs on anti-restenosis can be accelerated by additional coating with PDS, which has promising properties as a bioactive compound with useful anti-inflammatory effects.


Subject(s)
Blood Vessel Prosthesis , Drug Implants/administration & dosage , Drug-Eluting Stents , Graft Occlusion, Vascular/drug therapy , Graft Occlusion, Vascular/prevention & control , Prednisolone/administration & dosage , Sirolimus/administration & dosage , Animals , Anti-Inflammatory Agents/administration & dosage , Diffusion , Drug Combinations , Equipment Failure Analysis , Immunosuppressive Agents/administration & dosage , Male , Prednisolone/chemistry , Prosthesis Design , Rabbits , Treatment Outcome
9.
J Mater Sci Mater Med ; 26(10): 251, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26438653

ABSTRACT

The drug-eluting stent still has limitations such as thrombosis and inflammation. These limitations often occur in the absence of endothelialization. This study investigated the effects of WKYMVm- and sirolimus-coated stents on re-endothelialization and anti-restenosis. The WKYMVm peptide, specially synthesized for homing endothelial colony-forming cells, was coated onto a bare-metal stent with hyaluronic acid through a simple dip-coating method (designated HA-Pep). Thereafter, sirolimus was consecutively coated to onto the HA-Pep (designated Pep/SRL). The cellular response to stents by human umbilical-vein endothelial cells and vascular smooth-muscle cells was examined by XTT assay. Stents were implanted into rabbit iliac arteries, isolated 6 weeks post-implantation, and then subjected to histological analysis. The peptide was well attached to the surface of the stents and the sirolimus coating made the surface smooth. The release pattern for sirolimus was similar to that of commercial sirolimus-coated stents (57.2% within 7 days, with further release for up to 28 days). Endothelial-cell proliferation was enhanced in the HA-Pep group after 7 days of culture (38.2 ± 7.62%, compared with controls). On the other hand, the proliferation of smooth-muscle cells was inhibited in the Pep/SRL group after 7 days of culture (40.7 ± 6.71%, compared with controls). In an animal study, the restenosis rates for the Pep/SRL group (13.5 ± 4.50%) and commercial drug-eluting stents (Xience Prime™; 9.2 ± 7.20%) were lower than those for bare-metal stents (25.2 ± 4.52%) and HA-Pep stents (26.9 ± 3.88%). CD31 staining was incomplete for the bare-metal and Xience Prime™ groups. On the other hand, CD31 staining showed a consecutive linear pattern in the HA-Pep and Pep/SRL groups, suggesting that WKYMVm promotes endothelialization. These results indicate that the WKYMVm coating could promote endothelial healing, and consecutive coatings of WKYMVm and sirolimus onto bare-metal stents have a potential role in re-endothelialization and neointimal suppression.


Subject(s)
Coronary Restenosis/prevention & control , Drug-Eluting Stents , Oligopeptides/administration & dosage , Sirolimus/administration & dosage , Animals , Biocompatible Materials/administration & dosage , Cell Proliferation/drug effects , Cells, Cultured , Coronary Restenosis/pathology , Endothelium, Vascular/drug effects , Endothelium, Vascular/pathology , Human Umbilical Vein Endothelial Cells , Humans , Iliac Artery/drug effects , Iliac Artery/pathology , Iliac Artery/surgery , Male , Materials Testing , Myocytes, Smooth Muscle/drug effects , Myocytes, Smooth Muscle/pathology , Neointima/pathology , Neointima/prevention & control , Rabbits , Rats
10.
J Mater Sci Mater Med ; 26(4): 172, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25804307

ABSTRACT

Chronic total occlusions (CTOs) are common in patients with peripheral arterial disease (PAD). This study aimed to examine the feasibility and reliability of a CTO induced by a thin biodegradable polymer (polyglycolic acid) coated copper stent in a porcine femoral artery. Novel thin biodegradable polymer coated copper stents (9 mm long) were crimped on an angioplasty balloon (4.5 mm diameter × 12 mm length) and inserted into the femoral artery. Histopathologic analysis was performed 35 days after stenting. In five of six stented femoral arteries, severe in-stent restenosis and total occlusion with collateral circulation were observed without adverse effects such as acute stent thrombosis, leg necrosis, or death at 5 weeks. Fibrous tissue deposition, small vascular channels, calcification, and inflammatory cells were observed in hematoxylin-eosin, Carstair's, and von Kossa tissue stains; these characteristics were similar to pathological findings associated with CTOs in humans. The neointima volume measured by micro-computed tomography was 93.9 ± 4.04 % in the stented femoral arteries. CTOs were reliably induced by novel thin biodegradable polymer coated copper stents in porcine femoral arteries. Successful induction of CTOs may provide a practical understanding of their formation and application of an interventional device for CTO treatment.


Subject(s)
Absorbable Implants , Copper/chemistry , Disease Models, Animal , Graft Occlusion, Vascular/pathology , Polyglycolic Acid/chemistry , Stents , Animals , Blood Vessel Prosthesis , Coated Materials, Biocompatible/chemistry , Femoral Artery/pathology , Femoral Artery/physiopathology , Graft Occlusion, Vascular/physiopathology , Swine
SELECTION OF CITATIONS
SEARCH DETAIL
...