Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-24109729

ABSTRACT

To obtain real-time dose information in photon-beam therapy using a clinical linear accelerator, we fabricated a novel Cerenkov fiber-optic dosimeter using two plastic optical fibers without employing a scintillator. In this study, the light intensity and spectrum of Cerenkov radiation induced by a high-energy photon beam were measured as functions of the irradiation angle and the length difference between the two plastic optical fibers in the dosimeter probe. Also, we obtained a percentage depth dose curve for a 6 MV photon beam with a field size of 10 × 10 cm(2) according to the depth of the solid water phantom. Based on the results of this study, it is anticipated that the proposed Cerenkov fiber-optic dosimeter can be developed as a useful dosimeter to accurately obtain dose information prior to conducting radiotherapy.


Subject(s)
Radiotherapy/instrumentation , Feasibility Studies , Fiber Optic Technology , Humans , Optical Fibers , Phantoms, Imaging , Radiometry/instrumentation
2.
Radiat Prot Dosimetry ; 153(3): 294-9, 2013 Mar.
Article in English | MEDLINE | ID: mdl-22764176

ABSTRACT

In this study, a fibre-optic dosemeter (FOD) using an organic scintillator with a diameter of 0.5 mm for photon-beam therapy dosimetry was fabricated. The fabricated dosemeter has many advantages, including water equivalence, high spatial resolution, remote sensing and real-time measurement. The scintillating light generated from an organic-dosemeter probe embedded in a solid-water stack phantom is guided to a photomultiplier tube and an electrometer via 20 m of plastic optical fibre. Using this FOD, the skin dose and the percentage depth dose in the build-up region according to the depths of a solid-water stack phantom are measured with 6- and 15-MV photon-beam energies with field sizes of 10 × 10 and 20 × 20 cm(2), respectively. The results are compared with those measured using conventional dosimetry films. It is expected that the proposed FOD can be effectively used in radiotherapy dosimetry for accurate measurement of the skin dose and the depth dose distribution in the build-up region due to its high spatial resolution.


Subject(s)
Fiber Optic Technology/methods , Photons , Radiometry/instrumentation , Radiometry/methods , Skin/radiation effects , Calibration , Electrons , Equipment Design , Humans , Light , Optical Fibers , Phantoms, Imaging , Radiotherapy/methods , Radiotherapy Dosage , Scintillation Counting
SELECTION OF CITATIONS
SEARCH DETAIL
...