Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Forensic Sci Int ; 98(3): 193-200, 1998 Dec 21.
Article in English | MEDLINE | ID: mdl-9924788

ABSTRACT

This paper describes the results of three collaborative exercises which continues the EDNAP theme to explore whether uniformity of DNA profiling results could be achieved between European laboratories using STRs. In an earlier exercise, complex hypervariable AAAG-repeat STR loci were investigated, but reproducibility was found to be poor because of the variation of techniques used by participating laboratories. In the exercise reported here, an internal allelic ladder composed of ACTBP2 and D11S554 fragments was distributed. This ladder was used to size ACTBP2 analysed by a "singleplex" PCR amplification and D11S554 combined with APOAI1 in a separate "duplex" reaction. Laboratories were asked to test 7 blood stains, one of which was a known control, and to report the results to the co-ordinating laboratory. The exercise demonstrated that ACTBP2 showed good reproducibility between laboratories, whereas further testing would be needed to validate APOAI1 and D11S554 for interlaboratory comparisons. In separate exercises, the simple loci D12S391 and D1S1656 were tested; both of these showed excellent reproducibility between laboratories.


Subject(s)
DNA Fingerprinting/methods , DNA, Satellite/analysis , Immunoglobulin Variable Region/genetics , Minisatellite Repeats/genetics , Alleles , DNA, Satellite/blood , Europe , Humans , International Cooperation , Polymerase Chain Reaction , Reproducibility of Results , Societies, Medical
3.
Forensic Sci Int ; 86(1-2): 25-33, 1997 Apr 18.
Article in English | MEDLINE | ID: mdl-9153779

ABSTRACT

This paper describes a collaborative exercise which was intended to demonstrate whether uniformity of DNA profiling results could be achieved between European laboratories using two complex short tandem repeat (STR) loci. The loci D21S11 and HUMFIBRA (FGA) were chosen because they are commonly used by different European laboratories. D21S11 has approximately 14 common alleles (f > 0.001), whereas HUMFIBRA has 19 common alleles. Laboratories were asked to test seven blood stains, one of which was a known control, and to report the results to the coordinating laboratory. The exercise demonstrated that complex STRs were amenable to standardisation.


Subject(s)
Laboratories/standards , Repetitive Sequences, Nucleic Acid , Alleles , DNA , DNA Primers , Europe , Humans , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...