Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Rapid Commun Mass Spectrom ; 30(1): 143-50, 2016 Jan 15.
Article in English | MEDLINE | ID: mdl-26661981

ABSTRACT

RATIONALE: The doubly labelled water (DLW) method is a stable isotopic technique for measuring total energy expenditure (TEE). Saliva is the easiest sampling fluid for assessing isotopic enrichments, but blood is considered superior because of its rapid exchange with body water. Therefore, we compared a large range of isotopic enrichments in saliva and blood, and related TEE in subjects with their ad libitum total energy intake (TEI). The relevance of these parameters to body weight and fat change over an 8-day interval was also assessed. METHODS: Thirty subjects underwent DLW analysis over either 8 or 14 days, during which time initial and final blood and saliva enrichments were compared. TEI was assessed by dieticians over the 8-day period only. Isotope ratio mass spectrometry was used for the measurement of δ(2)H and δ(18)O values. RESULTS: No discrepancies were observed between sampling fluids over a wide range of enrichments. During the 8-day period, average TEI exceeded TEE by ~5% or less. Using saliva as sampling fluid, TEI and TEI-TEE, but not TEE, were positively correlated to body weight change. TEI-TEE and physical activity EE (AEE), but not TEI, correlated, respectively, positively and negatively to changes in fat mass. CONCLUSIONS: The DLW method in humans can be reliably applied using saliva as sampling fluid. TEI-TEE as well as AEE contributes significantly to changes in fat mass over an 8-day period.


Subject(s)
Deuterium Oxide/analysis , Energy Metabolism/physiology , Saliva/chemistry , Adult , Deuterium/analysis , Humans , Male , Mass Spectrometry , Oxygen Isotopes/analysis
2.
Rapid Commun Mass Spectrom ; 23(7): 999-1019, 2009 Apr.
Article in English | MEDLINE | ID: mdl-19263478

ABSTRACT

Internationally distributed organic and inorganic oxygen isotopic reference materials have been calibrated by six laboratories carrying out more than 5300 measurements using a variety of high-temperature conversion techniques (HTC)a in an evaluation sponsored by the International Union of Pure and Applied Chemistry (IUPAC). To aid in the calibration of these reference materials, which span more than 125 per thousand, an artificially enriched reference water (delta(18)O of +78.91 per thousand) and two barium sulfates (one depleted and one enriched in (18)O) were prepared and calibrated relative to VSMOW2b and SLAP reference waters. These materials were used to calibrate the other isotopic reference materials in this study, which yielded: Reference material delta(18)O and estimated combined uncertainty IAEA-602 benzoic acid+71.28 +/- 0.36 per thousand USGS 35 sodium nitrate+56.81 +/- 0.31 per thousand IAEA-NO-3 potassium nitrate+25.32 +/- 0.29 per thousand IAEA-601 benzoic acid+23.14 +/- 0.19 per thousand IAEA-SO-5 barium sulfate+12.13 +/- 0.33 per thousand NBS 127 barium sulfate+8.59 +/- 0.26 per thousand VSMOW2 water 0 per thousand IAEA-600 caffeine-3.48 +/- 0.53 per thousand IAEA-SO-6 barium sulfate-11.35 +/- 0.31 per thousand USGS 34 potassium nitrate-27.78 +/- 0.37 per thousand SLAP water-55.5 per thousand The seemingly large estimated combined uncertainties arise from differences in instrumentation and methodology and difficulty in accounting for all measurement bias. They are composed of the 3-fold standard errors directly calculated from the measurements and provision for systematic errors discussed in this paper. A primary conclusion of this study is that nitrate samples analyzed for delta(18)O should be analyzed with internationally distributed isotopic nitrates, and likewise for sulfates and organics. Authors reporting relative differences of oxygen-isotope ratios (delta(18)O) of nitrates, sulfates, or organic material should explicitly state in their reports the delta(18)O values of two or more internationally distributed nitrates (USGS 34, IAEA-NO-3, and USGS 35), sulfates (IAEA-SO-5, IAEA-SO-6, and NBS 127), or organic material (IAEA-601 benzoic acid, IAEA-602 benzoic acid, and IAEA-600 caffeine), as appropriate to the material being analyzed, had these reference materials been analyzed with unknowns. This procedure ensures that readers will be able to normalize the delta(18)O values at a later time should it become necessary.The high-temperature reduction technique for analyzing delta(18)O and delta(2)H is not as widely applicable as the well-established combustion technique for carbon and nitrogen stable isotope determination. To obtain the most reliable stable isotope data, materials should be treated in an identical fashion; within the same sequence of analyses, samples should be compared with working reference materials that are as similar in nature and in isotopic composition as feasible.


Subject(s)
Hot Temperature , Laboratories/standards , Mass Spectrometry/methods , Nitrates/chemistry , Oxygen Isotopes/chemistry , Sulfates/chemistry , Calibration , Reference Standards , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...