1.
Radiat Prot Dosimetry ; 148(2): 162-7, 2012 Jan.
Article in English | MEDLINE | ID: mdl-21406429

ABSTRACT

The authors present the results of a year-long survey of the indoor radon concentration levels in the FYR of Macedonia. A total number of 437 dwellings in eight statistical regions were subject to radon concentration measurements by using CR-39 track detectors. The annual mean indoor radon concentration in each measuring site was estimated from the four individual measurements with 3 months duration. The measuring period was from December 2008 to December 2009. The distribution of the results was nearly log-normal. The arithmetic and geometric mean values of the annual mean value of radon concentration were estimated to be 105 ± 84 and 84*/1.9 Bq m(-3), respectively. The annual effective dose due to indoor exposure to radon in the dwellings was estimated to be 2.1*/1.9 mSv y(-1).


Subject(s)
Air Pollution, Indoor/analysis , Air Pollution, Radioactive/analysis , Radiation Monitoring , Radon/analysis , Humans