Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
PLoS One ; 15(1): e0227651, 2020.
Article in English | MEDLINE | ID: mdl-31923919

ABSTRACT

We tested the influence of blood pressure variability on the reproducibility of dynamic cerebral autoregulation (DCA) estimates. Data were analyzed from the 2nd CARNet bootstrap initiative, where mean arterial blood pressure (MABP), cerebral blood flow velocity (CBFV) and end tidal CO2 were measured twice in 75 healthy subjects. DCA was analyzed by 14 different centers with a variety of different analysis methods. Intraclass Correlation (ICC) values increased significantly when subjects with low power spectral density MABP (PSD-MABP) values were removed from the analysis for all gain, phase and autoregulation index (ARI) parameters. Gain in the low frequency band (LF) had the highest ICC, followed by phase LF and gain in the very low frequency band. No significant differences were found between analysis methods for gain parameters, but for phase and ARI parameters, significant differences between the analysis methods were found. Alternatively, the Spearman-Brown prediction formula indicated that prolongation of the measurement duration up to 35 minutes may be needed to achieve good reproducibility for some DCA parameters. We conclude that poor DCA reproducibility (ICC<0.4) can improve to good (ICC > 0.6) values when cases with low PSD-MABP are removed, and probably also when measurement duration is increased.


Subject(s)
Blood Pressure Determination/methods , Cerebrovascular Circulation/physiology , Homeostasis/physiology , Adult , Aged , Arterial Pressure/physiology , Blood Flow Velocity/physiology , Blood Pressure/physiology , Female , Healthy Volunteers , Humans , Male , Middle Aged , Middle Cerebral Artery/physiopathology , Reproducibility of Results
2.
Front Physiol ; 10: 865, 2019.
Article in English | MEDLINE | ID: mdl-31354518

ABSTRACT

Parameters describing dynamic cerebral autoregulation (DCA) have limited reproducibility. In an international, multi-center study, we evaluated the influence of multiple analytical methods on the reproducibility of DCA. Fourteen participating centers analyzed repeated measurements from 75 healthy subjects, consisting of 5 min of spontaneous fluctuations in blood pressure and cerebral blood flow velocity signals, based on their usual methods of analysis. DCA methods were grouped into three broad categories, depending on output types: (1) transfer function analysis (TFA); (2) autoregulation index (ARI); and (3) correlation coefficient. Only TFA gain in the low frequency (LF) band showed good reproducibility in approximately half of the estimates of gain, defined as an intraclass correlation coefficient (ICC) of >0.6. None of the other DCA metrics had good reproducibility. For TFA-like and ARI-like methods, ICCs were lower than values obtained with surrogate data (p < 0.05). For TFA-like methods, ICCs were lower for the very LF band (gain 0.38 ± 0.057, phase 0.17 ± 0.13) than for LF band (gain 0.59 ± 0.078, phase 0.39 ± 0.11, p ≤ 0.001 for both gain and phase). For ARI-like methods, the mean ICC was 0.30 ± 0.12 and for the correlation methods 0.24 ± 0.23. Based on comparisons with ICC estimates obtained from surrogate data, we conclude that physiological variability or non-stationarity is likely to be the main reason for the poor reproducibility of DCA parameters.

3.
Physiol Meas ; 39(12): 125002, 2018 12 07.
Article in English | MEDLINE | ID: mdl-30523976

ABSTRACT

OBJECTIVE: Different methods to calculate dynamic cerebral autoregulation (dCA) parameters are available. However, most of these methods demonstrate poor reproducibility that limit their reliability for clinical use. Inter-centre differences in study protocols, modelling approaches and default parameter settings have all led to a lack of standardisation and comparability between studies. We evaluated reproducibility of dCA parameters by assessing systematic errors in surrogate data resulting from different modelling techniques. APPROACH: Fourteen centres analysed 22 datasets consisting of two repeated physiological blood pressure measurements with surrogate cerebral blood flow velocity signals, generated using Tiecks curves (autoregulation index, ARI 0-9) and added noise. For reproducibility, dCA methods were grouped in three broad categories: 1. Transfer function analysis (TFA)-like output; 2. ARI-like output; 3. Correlation coefficient-like output. For all methods, reproducibility was determined by one-way intraclass correlation coefficient analysis (ICC). MAIN RESULTS: For TFA-like methods the mean (SD; [range]) ICC gain was 0.71 (0.10; [0.49-0.86]) and 0.80 (0.17; [0.36-0.94]) for VLF and LF (p = 0.003) respectively. For phase, ICC values were 0.53 (0.21; [0.09-0.80]) for VLF, and 0.92 (0.13; [0.44-1.00]) for LF (p < 0.001). Finally, ICC for ARI-like methods was equal to 0.84 (0.19; [0.41-0.94]), and for correlation-like methods, ICC was 0.21 (0.21; [0.056-0.35]). SIGNIFICANCE: When applied to realistic surrogate data, free from the additional exogenous influences of physiological variability on cerebral blood flow, most methods of dCA modelling showed ICC values considerably higher than what has been reported for physiological data. This finding suggests that the poor reproducibility reported by previous studies may be mainly due to the inherent physiological variability of cerebral blood flow regulatory mechanisms rather than related to (stationary) random noise and the signal analysis methods.


Subject(s)
Cerebrovascular Circulation , Homeostasis , Aged , Blood Pressure Determination , Female , Humans , Male , Reproducibility of Results
4.
Acta Neurochir Suppl ; 126: 153-157, 2018.
Article in English | MEDLINE | ID: mdl-29492552

ABSTRACT

OBJECTIVE: To devise an appropriate measure of the quality of a magnetic resonance imaging (MRI) signal for the assessment of dynamic cerebral autoregulation, and propose simple strategies to improve its quality. MATERIALS AND METHODS: Magnetic resonance images of 11 healthy subjects were scanned during a transient decrease in arterial blood pressure (BP). Mean signals were extracted from non-overlapping brain regions for each image. An ad-hoc contrast-to-noise ratio (CNR) was used to evaluate the quality of these regional signals. Global mean signals were obtained by averaging the set of regional signals resulting after applying a Hampel filter and discarding a proportion of the lower quality component signals. RESULTS: Significant improvements in CNR values of global mean signals were obtained, whilst maintaining significant correlation with the original ones. A Hampel filter with a small moving window and a low rejection threshold combined with a selection of the 50% component signals seems a recommendable option. CONCLUSIONS: This work has demonstrated the possibility of improving the quality of MRI signals acquired during transient drops in BP. This approach needs validation at a voxel level, which could help to consolidate MRI as a technological alternative to the standard techniques for the study of cerebral autoregulation.


Subject(s)
Arterial Pressure/physiology , Brain/diagnostic imaging , Cerebrovascular Circulation/physiology , Homeostasis/physiology , Magnetic Resonance Imaging/methods , Healthy Volunteers , Humans , Signal-To-Noise Ratio
5.
Acta Neurochir Suppl ; 126: 159-162, 2018.
Article in English | MEDLINE | ID: mdl-29492553

ABSTRACT

OBJECTIVE: We analyzed the performance of linear and nonlinear models to assess dynamic cerebral autoregulation (dCA) from spontaneous variations in healthy subjects and compared it with the use of two known maneuvers to abruptly change arterial blood pressure (BP): thigh cuffs and sit-to-stand. MATERIALS AND METHODS: Cerebral blood flow velocity and BP were measured simultaneously at rest and while the maneuvers were performed in 20 healthy subjects. To analyze the spontaneous variations, we implemented two types of models using support vector machine (SVM): linear and nonlinear finite impulse response models. The classic autoregulation index (ARI) and the more recently proposed model-free ARI (mfARI) were used as measures of dCA. An ANOVA analysis was applied to compare the different methods and the coefficient of variation was calculated to evaluate their variability. RESULTS: There are differences between indexes, but not between models and maneuvers. The mfARI index with the sit-to-stand maneuver shows the least variability. CONCLUSIONS: Support vector machine modeling of spontaneous variation with the mfARI index could be used for the assessment of dCA as an alternative to maneuvers to introduce large BP fluctuations.


Subject(s)
Arterial Pressure/physiology , Blood Flow Velocity/physiology , Cerebrovascular Circulation/physiology , Homeostasis/physiology , Posture/physiology , Adult , Female , Healthy Volunteers , Humans , Linear Models , Male , Middle Cerebral Artery/diagnostic imaging , Nonlinear Dynamics , Support Vector Machine , Ultrasonography, Doppler, Transcranial , Young Adult
6.
J Cereb Blood Flow Metab ; 36(12): 2194-2202, 2016 12.
Article in English | MEDLINE | ID: mdl-26661230

ABSTRACT

Novel MRI-based dynamic cerebral autoregulation (dCA) assessment enables the estimation of both global and spatially discriminated autoregulation index values. Before exploring this technique for the evaluation of focal dCA in acute ischaemic stroke (AIS) patients, it is necessary to compare global dCA estimates made using both TCD and MRI. Both techniques were used to study 11 AIS patients within 48 h of symptom onset, and nine healthy controls. dCA was assessed by the rate of return of CBFV (Rturn) following a sudden drop induced by the thigh cuff manoeuvre. No significant between-hemisphere differences were seen in controls using either the TCD or MRI technique. Inter-hemisphere averaged Rturn values were not different between TCD (1.89 ± 0.67%/s) and MRI (2.07 ± 0.60%/s) either. In patients, there were no differences between the affected and unaffected hemispheres whether assessed by TCD (Rturn 0.67 ± 0.72 vs. 0.98 ± 1.09%/s) or MRI (0.55 ± 1.51 vs. 1.63 ± 0.63%/s). Rturn for both TCD and MRI was impaired in AIS patients compared to controls in both unaffected and affected hemispheres (ANOVA, p = 0.00005). These findings pave the way for wider use of MRI for dCA assessment in health and disease.


Subject(s)
Brain Ischemia/physiopathology , Homeostasis , Magnetic Resonance Imaging/standards , Stroke/physiopathology , Ultrasonography, Doppler, Transcranial/standards , Adult , Blood Flow Velocity , Blood Pressure , Case-Control Studies , Cerebrovascular Circulation , Female , Humans , Magnetic Resonance Imaging/methods , Male , Middle Aged , Ultrasonography, Doppler, Transcranial/methods
7.
Food Res Int ; 85: 51-58, 2016 Jul.
Article in English | MEDLINE | ID: mdl-29544852

ABSTRACT

Passion fruit seeds are currently discarded on the pulp processing but are known for their high piceatannol and scirpusin B contents. Using pressurized liquid extraction (PLE), these highly valuable phenolic compounds were efficiently extracted from defatted passion fruit bagasse (DPFB). PLE was performed using mixtures of ethanol and water (50 to 100% ethanol, w/w) as solvent, temperatures from 50 to 70°C and pressure at 10MPa. The extraction methods were compared in terms of the global yield, total phenolic content (TPC), piceatannol content and the antioxidant capacity of the extracts. The DPFB extracts were also compared with those from non-defatted passion fruit bagasse (nDPFB). Identification and quantification of piceatannol were performed using UHPLC-MS/MS. The results showed that high TPC and piceatannol content were achieved for the extracts obtained from DPFB through PLE at 70°C and using 50 and 75% ethanol as the solvent. The best PLE conditions for TPC (70°C, 75% ethanol) resulted in 55.237mgGAE/g dried and defatted bagasse, whereas PLE at 70°C and 50% ethanol achieved 18.590mg of piceatannol/g dried and defatted bagasse, and such yields were significantly higher than those obtained using conventional extraction techniques. The antioxidant capacity assays showed high correlation with the TPC (r>0.886) and piceatannol (r>0.772). The passion fruit bagasse has therefore proved to be a rich source of piceatannol and PLE showed high efficiency to recover phenolic compounds from defatted passion fruit bagasse.

8.
PLoS One ; 8(4): e62588, 2013.
Article in English | MEDLINE | ID: mdl-23638121

ABSTRACT

A novel method is described for mapping dynamic cerebral blood flow autoregulation to assess autoregulatory efficiency throughout the brain, using magnetic resonance imaging (MRI). Global abnormalities in autoregulation occur in clinical conditions, including stroke and head injury, and are of prognostic significance. However, there is limited information about regional variations. A gradient-echo echo-planar pulse sequence was used to scan the brains of healthy subjects at a rate of 1 scan/second during a transient decrease in arterial blood pressure provoked by a sudden release of pressure in bilateral inflated thigh cuffs. The signal decrease and subsequent recovery were analyzed to provide an index of autoregulatory efficiency (MRARI). MRI time-series were successfully acquired and analyzed in eleven subjects. Autoregulatory efficiency was not uniform throughout the brain: white matter exhibited faster recovery than gray (MRARI = 0.702 vs. 0.672, p = 0.009) and the cerebral cortex exhibited faster recovery than the cerebellum (MRARI = 0.669 vs. 0.645, p = 0.016). However, there was no evidence for differences between different cortical regions. Differences in autoregulatory efficiency between white matter, gray matter and the cerebellum may be a result of differences in vessel density and vasodilation. The techniques described may have practical importance in detecting regional changes in autoregulation consequent to disease.


Subject(s)
Brain/blood supply , Brain/physiology , Magnetic Resonance Imaging/methods , Adult , Aged , Arterial Pressure , Brain/physiopathology , Female , Homeostasis , Humans , Male , Middle Aged
9.
Rev. méd. Chile ; 140(12): 1517-1528, dic. 2012. ilus, tab
Article in Spanish | LILACS | ID: lil-674022

ABSTRACT

Background: Rates ofmorbidity and mortality in Infective Endocarditis (IE) remain high and prognosis in this disease is still difficult and uncertain. Aim: To study IE in Chile in its active phase during inpatient hospital stay and long term survival rates. Material and Methods: Observational prospective national cohort study of 506 consecutive patients included between June 1,1998 and July 31, 2008, from 37 Chilean hospitals (secondary and tertiary centers) nationwide. Results: The main findings were the presence of Rheumatic valve disease in 22.1 % of patients, a history of intravenous drug abuse (IVDA) only in 0.7%, the presence of Staphylo-coccus aureus in 29.2% of blood cultures, negative blood cultures in 33.2%, heart failure in 51.7% and native valve involvement in 86% ofpatients. Echocardiographic diagnosis was achieved in 94% of patients. Hospital mortality was 26.1% and its prognostics factors were persisting infection (Odds ratio (OR) 6.43, Confidence Interval (CI) 1.45-28.33%), failure of medical treatment and no surgical intervention (OR 48.8; CI 6.67-349.9). Five and 10 years survival rates were 75.6 and 48.6%, respectively. The significant prognostic factors for long term mortality, determined by multivariate analysis were the presence of diabetes, Staphylococcus aureus infection, sepsis, heart failure, renal failure and lack of surgical treatment during the IE episode. Conclusions: The microbiologic diagnosis of IE must be urgently improved in Chile. Mortality rates are still high (26.1%) partly because of a high incidence of negative blood cultures and the need for more surgical valve interventions during in-hospital period. Long term prognostic factors for mortality should be identified early to improve outcome.


Subject(s)
Adolescent , Adult , Aged , Aged, 80 and over , Child , Female , Humans , Male , Middle Aged , Young Adult , Endocarditis, Bacterial/mortality , Hospital Mortality/trends , Rheumatic Heart Disease/mortality , Blood Specimen Collection/standards , Cardiac Surgical Procedures/mortality , Cardiac Surgical Procedures/statistics & numerical data , Chile/epidemiology , Endocarditis, Bacterial/diagnosis , Endocarditis, Bacterial/surgery , Epidemiologic Methods , Prognosis , Rheumatic Heart Disease/diagnosis , Rheumatic Heart Disease/surgery , Risk Factors , Survival Rate/trends
10.
Analyst ; 137(11): 2537-40, 2012 Jun 07.
Article in English | MEDLINE | ID: mdl-22349120

ABSTRACT

An exceptionally easy to assemble source for ambient mass spectrometry is described. Based on Venturi easy ambient sonic-spray ionization (V-EASI), the source was further simplified by the use of a can of compressed air which simultaneously provides solution or solvent Venturi self-pumping and continuous, stable and abundant low-noise ion signal via voltage-free sonic-spraying. Further simplification was also attained by the use of inexpensive and readily commercially available parts: a surgical 2-way catheter, an aerosol can of compressed air, a 30 cm long fused-silica capillary and a hypodermic needle. This "Spartan" V-EASI source seems to offer one of the easiest and cheapest ways to make ions for ambient desorption/ionization mass spectrometry analysis of both liquid and solid samples.

11.
Rev Med Chil ; 140(12): 1517-28, 2012 Dec.
Article in Spanish | MEDLINE | ID: mdl-23677223

ABSTRACT

BACKGROUND: Rates of morbidity and mortality in Infective Endocarditis (IE) remain high and prognosis in this disease is still difficult and uncertain. AIM: To study IE in Chile in its active phase during inpatient hospital stay and long term survival rates. MATERIAL AND METHODS: Observational prospective national cohort study of 506 consecutive patients included between June 1,1998 and July 31, 2008, from 37 Chilean hospitals (secondary and tertiary centers) nationwide. RESULTS: The main findings were the presence of Rheumatic valve disease in 22.1 % of patients, a history of intravenous drug abuse (IVDA) only in 0.7%, the presence of Staphylococcus aureus in 29.2% of blood cultures, negative blood cultures in 33.2%, heart failure in 51.7% and native valve involvement in 86% of patients. Echocardiographic diagnosis was achieved in 94% of patients. Hospital mortality was 26.1% and its prognostics factors were persisting infection (Odds ratio (OR) 6.43, Confidence Interval (CI) 1.45-28.33%), failure of medical treatment and no surgical intervention (OR 48.8; CI 6.67-349.9). Five and 10 years survival rates were 75.6 and 48.6%, respectively. The significant prognostic factors for long term mortality, determined by multivariate analysis were the presence of diabetes, Staphylococcus aureus infection, sepsis, heart failure, renal failure and lack of surgical treatment during the IE episode. CONCLUSIONS: The microbiologic diagnosis of IE must be urgently improved in Chile. Mortality rates are still high (26.1%) partly because of a high incidence of negative blood cultures and the need for more surgical valve interventions during in-hospital period. Long term prognostic factors for mortality should be identified early to improve outcome.


Subject(s)
Endocarditis, Bacterial/mortality , Hospital Mortality/trends , Rheumatic Heart Disease/mortality , Adolescent , Adult , Aged , Aged, 80 and over , Blood Specimen Collection/standards , Cardiac Surgical Procedures/mortality , Cardiac Surgical Procedures/statistics & numerical data , Child , Chile/epidemiology , Endocarditis, Bacterial/diagnosis , Endocarditis, Bacterial/surgery , Epidemiologic Methods , Female , Humans , Male , Middle Aged , Prognosis , Rheumatic Heart Disease/diagnosis , Rheumatic Heart Disease/surgery , Risk Factors , Survival Rate/trends , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...