Orthopade ; 30(3): 161-8, 2001 Mar.
Article in German | MEDLINE | ID: mdl-11501007

ABSTRACT

The influence of three alignment parameters of a transtibial prosthesis (sagittal foot position, plantar flexion, mediolateral foot position) on the load and motion of the lower extremity joints was investigated in 13 unilateral transtibial amputees. The aim was to determine whether a correlation exists between static prosthetic alignment and gait pattern that would allow an optimal biomechanical prosthetic alignment. The gait pattern was measured using kinematic, kinetic, and electromyographic methods. Statics was defined using the alignment apparatus L.A.S.A.R. Posture. The electromyogram of the m. vastus lateralis and m. biceps femoris was recorded on both sides. The motion of joints is described by joint angles. External joint moments define the mechanical loads. Alignment has almost no influence on muscle activity and joint mechanics of the contralateral leg. In contrast, prosthetic alignment affects clearly and systematically the load and motion of the knee joint during the stance phase on the ipsilateral side. The sagittal foot position influences the maximal flexion angle in the stance phase. The plantar flexion of the foot affects the temporal structure of knee motion. The mediolateral foot position causes correspondingly different varus and valgus moments acting on the knee. Swing phase motion does not depend on prosthetic alignment. The iEMG of the m. vastus lateralis is reduced. Innervation characteristics of the m. biceps femoris on the prosthetically fitted leg has completely changed. The ischiocrural muscles take over the neuromuscular action of the m. gastrocnemius to compensate for the external knee extension moment during the second part of the stance phase. Prosthetic statics determines if the knee joint is physiologically stressed in a standing posture and during walking. Statics will be correct if the anatomical knee axis of the standing amputee is located about 15 mm posterior to the load line in the sagittal plane. In the frontal plane, the load line touches the lateral patella border and strikes the middle of the foot about 5 cm anterior to the adapter. During walking, attention should be paid to performance of knee flexion in the stance phase.


Subject(s)
Artificial Limbs , Walking , Weight-Bearing , Adult , Aged , Artificial Limbs/standards , Biomechanical Phenomena , Female , Gait , Humans , Male , Middle Aged , Prosthesis Design , Prosthesis Fitting
2.
Prosthet Orthot Int ; 23(3): 231-8, 1999 Dec.
Article in English | MEDLINE | ID: mdl-10890598

ABSTRACT

The influence of sagittal plane prosthetic alignment changes on loads applied to the ispilateral knee was investigated using 5 transtibial amputee subjects. The goal was to determine which prosthetic alignment results in the most energy efficient standing and also minimises stresses on knee structures during standing. The electromyogram, the external mechanical loading of the prosthetic leg and the amputees' posture were recorded for a wide range of prosthetic alignments. The EMG of the vastus lateralis and biceps femoris muscles was measured bilaterally; the EMG of the gastrocnemius muscle was measured only on the contralateral side. The distance between the anatomical knee centre and each individual's load line, as determined by the Otto Bock "L.A.S.A.R. Posture" alignment system, was used as a measure of the mechanical load applied to the knee joint. Prosthetic alignment has almost no influence on muscle activity of the contralateral lower limb during static standing. On the other hand, prosthetic alignment has a significant influence on the load applied to the amputee's ipsilateral knee joint. The external knee moments applied to the knee ligaments and knee muscles on the amputated side change systematically in response to different plantar flexion or dorsiflexion angles of the prosthetic ankle-foot. During standing the extensor muscles stabilise the limb by contracting if the load line is located less than 15 mm anterior to the anatomical knee centre. The biceps femoris muscle appears to have little or no protective function against hyperextension during standing even if large external knee extension moments are caused by excessive plantar flexion. Such extreme alignments significantly increase the stresses on knee ligaments and the posterior knee capsule. When prosthetic sagittal plane alignment is altered, the trans-tibial amputee compensates by balancing the upper part of the body over the centre of pressure of the prosthetic foot. Biomechanically optimal alignment of the trans-tibial prosthesis occurs when the individual load line is approximately 15 mm anterior to the anatomical knee centre, permitting a comfortable, energy efficient standing and minimising the mechanical loading on the knee structures.


Subject(s)
Artificial Limbs , Knee Joint/physiology , Adult , Aged , Biomechanical Phenomena , Electromyography , Humans , Middle Aged , Muscle, Skeletal/physiology