1.
Cardiology ; 2024 May 07.
Article in English | MEDLINE | ID: mdl-38714182

ABSTRACT

INTRODUCTION: This pooled analysis was conducted to assess the clinical safety and performance of the Supra family (Sahajanand Medical Technologies Ltd., Surat, India) of sirolimus-eluting stents (SES) in patients with acute coronary syndromes (ACS) including ST segment elevation myocardial infarction (STEMI) from two real-world all-comers Indian registries at one-year. METHODS: We evaluated 1824 patients with ACS who underwent percutaneous coronary intervention with the Supra family of SES from two real-world Indian registries (891 patients from T-Flex registry and 933 patients from Tetriflex real-world registry). The primary endpoint was the incidence of target lesion failure (TLF) defined as a composite of cardiac death, target vessel myocardial infarction (TV-MI), and target lesion revascularization (TLR) at one-year follow-up. The safety endpoint was stent thrombosis at one-year follow-up. RESULTS: Among a total of 1824 patients with ACS, 689 (37.8%) patients presented with STEMI. In ACS and STEMI groups, 47.6% and 41.8% patients had multi-vessel disease, respectively. Of 2128 lesions in ACS group, 76.7% lesions were type B2/C and 16.2% lesions were totally occluded. In the STEMI group, out of 784 treated lesions, 76.7% were type B2/C lesions and 21.9% were totally occluded. At one-year follow-up, incidence of TLF was 5.3% (cardiac death: 0.9%, TV-MI: 2.5%, TLR: 1.9%) in patients with ACS and 6.2% (cardiac death: 1.4%, TV-MI: 2.1%, TLR: 2.7%) in patients with STEMI. The one-year rate of definite/probable stent thrombosis were 0.3% and 0.7% in patients with ACS and STEMI, respectively. CONCLUSION: This patient-level pooled analysis provides evidence for the safe and effective use of the Supra family of SES in complex patient populations such as ACS and even in STEMI with favourable rates of TLF and stent thrombosis at one-year follow-up.

2.
Vasc Health Risk Manag ; 15: 439-447, 2019.
Article in English | MEDLINE | ID: mdl-31695399

ABSTRACT

BACKGROUND: Although a number of drug-eluting stents have been developed with different design, composition, and polymers, the search for an ideal drug-eluting stent is ongoing. The Tetriflex (Sahajanand Medical Technology, Surat, India) is a newer-generation, ultrathin (60 µm) biodegradable polymer-coated sirolimus-eluting stent (SES) designed with a unique long dual Z-link on a cobalt-chromium alloy. The present registry aimed to evaluate the safety and clinical outcomes of the Tetriflex SES at 6-month post-implantation. METHODS: This was an investigator-initiated, retrospective, multicenter, single-arm, observational registry conducted at five tertiary-care centers in India. A total of 1,269 consecutive patients with coronary artery disease who underwent implantation of at least one Tetriflex SES between March 2017 and March 2018 were included. The primary outcome was considered a composite of cardiac death, myocardial infarction and target-lesion revascularization (TLR) at 6-month follow-up. Stent thrombosis was evaluated as a safety outcome at 6-month follow-up. RESULTS: The mean age of patients was 54.99±10.80 years. Among 1,515 lesions treated with 1,682 Tetriflex SES, 58.3% were type C lesions. Six-month follow-up was done for 1,245 of 1,269 (98.1%) patients. At 6 months, composite events had occurred in 31 (2.5%) patients, consisting of ten (0.8%) cardiac deaths, 16 (1.3%) myocardial infarctions, and five (0.4%) TLRs. Stent thrombosis was observed in seven (0.56%) cases at 6 months. A subgroup analysis between diabetic and nondiabetic patients did not reveal any statistically significant difference for clinical outcomes at 6-month follow-up. CONCLUSION: The results of the current registry outline the safety and effectiveness of the Tetriflex SES in real-world patients, as it displayed favorable clinical outcomes at 6-month follow-up, with low incidence of TLR and stent thrombosis.


Subject(s)
Cardiovascular Agents/administration & dosage , Coated Materials, Biocompatible , Coronary Artery Disease/therapy , Coronary Occlusion/therapy , Drug-Eluting Stents , Percutaneous Coronary Intervention/instrumentation , Sirolimus/administration & dosage , Adult , Cardiovascular Agents/adverse effects , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Coronary Occlusion/diagnostic imaging , Coronary Occlusion/mortality , Coronary Thrombosis/epidemiology , Female , Humans , Incidence , India/epidemiology , Male , Middle Aged , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Prosthesis Design , Registries , Retrospective Studies , Risk Factors , Sirolimus/adverse effects , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...