Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Heart Rhythm ; 2024 Apr 07.
Article in English | MEDLINE | ID: mdl-38588995

ABSTRACT

BACKGROUND: The CONVERGE trial demonstrated that hybrid epicardial and endocardial ablation was more effective than catheter ablation for the treatment of persistent atrial fibrillation (AF) at 1 year. Long-term real-world outcome data are scarce. OBJECTIVE: We described a single-center experience by evaluating the long-term effectiveness and safety of hybrid epicardial-endocardial ablation. METHODS: This is a retrospective single-center study. Patients were followed up to 4 years. The primary end point was the rate of AF recurrence up to 4 years postablation. Secondary end points included reduction in antiarrhythmic therapy use, the effect of the ligament of Marshall removal, epicardial posterior wall, 3-dimensional mapping during epicardial ablation, and left atrial appendage exclusion as adjunct intraoperative interventions for AF recurrence. RESULTS: Of the 170 patients, 86.5% had persistent AF and 13.5% had long-standing persistent AF. AF-free survival was 87.6% at 1 year, 76.9% at 2 years, 70.4% at 3 years, and 59.3% at 4 years. Antiarrhythmic drug use was 87.6% at baseline and reduced to 21%, 20.6%, 18%, and 14.1% at year 1, 2, 3, and 4, respectively (P < .01 for all). Three-dimensional epicardial mapping showed a significant reduction in combined recurrence from 42% to 25% over 4 years of follow-up (P = .023). Ligament of Marshall and left atrial appendage exclusion showed numerical reduction in AF recurrence from 35% to 26% (P = .49) and from 44% to 30% (P = .07). CONCLUSION: The hybrid convergent procedure reduces AF recurrence and the need for antiarrhythmic drugs and, while maintaining a good safety profile, for the treatment of persistent and long-standing persistent AF.

2.
JAMA Netw Open ; 5(7): e2220597, 2022 07 01.
Article in English | MEDLINE | ID: mdl-35797046

ABSTRACT

Importance: Transesophageal echocardiography during percutaneous left atrial appendage closure (LAAO) and transcatheter edge-to-edge mitral valve repair (TEER) require an interventional echocardiographer to stand near the radiation source and patient, the primary source of scatter radiation. Despite previous work demonstrating high radiation exposure for interventional cardiologists performing percutaneous coronary and structural heart interventions, similar data for interventional echocardiographers are lacking. Objective: To assess whether interventional echocardiographers are exposed to greater radiation doses than interventional cardiologists and sonographers during structural heart procedures. Design, Setting, and Participants: In this single-center cross-sectional study, radiation doses were collected from interventional echocardiographers, interventional cardiologists, and sonographers at a quaternary care center during 30 sequential LAAO and 30 sequential TEER procedures from July 1, 2016, to January 31, 2018. Participants and study personnel were blinded to radiation doses through data analysis (January 1, 2020, to October 12, 2021). Exposures: Occupation defined as interventional echocardiographers, interventional cardiologists, and sonographers. Main Outcomes and Measures: Measured personal dose equivalents per case were recorded using real-time radiation dosimeters. Results: A total of 60 (30 TEER and 30 LAAO) procedures were performed in 60 patients (mean [SD] age, 79 [8] years; 32 [53.3%] male) with a high cardiovascular risk factor burden. The median radiation dose per case was higher for interventional echocardiographers (10.6 µSv; IQR, 4.2-22.4 µSv) than for interventional cardiologists (2.1 µSv; IQR, 0.2-8.3 µSv; P < .001). During TEER, interventional echocardiographers received a median radiation dose of 10.5 µSv (IQR, 3.1-20.5 µSv), which was higher than the median radiation dose received by interventional cardiologists (0.9 µSv; IQR, 0.1-12.2 µSv; P < .001). During LAAO procedures, the median radiation dose was 10.6 µSv (IQR, 5.8-24.1 µSv) among interventional echocardiographers and 3.5 (IQR, 1.3-6.3 µSv) among interventional cardiologists (P < .001). Compared with interventional echocardiographers, sonographers exhibited low median radiation doses during both LAAO (0.2 µSv; IQR, 0.0-1.6 µSv; P < .001) and TEER (0.0 µSv; IQR, 0.0-0.1 µSv; P < .001). Conclusions and Relevance: In this cross-sectional study, interventional echocardiographers were exposed to higher radiation doses than interventional cardiologists during LAAO and TEER procedures, whereas sonographers demonstrated comparatively lower radiation doses. Higher radiation doses indicate a previously underappreciated occupational risk faced by interventional echocardiographers, which has implications for the rapidly expanding structural heart team.


Subject(s)
Cardiologists , Occupational Exposure , Radiation Exposure , Aged , Cross-Sectional Studies , Female , Humans , Male , Occupational Exposure/adverse effects , Occupational Exposure/prevention & control , Radiation Dosage
3.
Am Heart J Plus ; 21: 100195, 2022 Sep.
Article in English | MEDLINE | ID: mdl-38559748

ABSTRACT

Background: Detection of atrial fibrillation (AF) in patients with embolic stroke of undetermined source (ESUS) is challenging due to its paroxysmal nature. We sought to assess AF detection with an insertable cardiac monitor (ICM) and to perform cost analysis for various AF monitoring strategies post-ESUS We applied this cost analysis modeling to recently published Stroke AF and Per Diem trials. Methods: Retrospective chart review was performed in consecutive hospitalized patients with ESUS who had ICM placed prior to discharge. Utilizing rate of ICM-detected AF and Medicare average payments, we modeled 30-day per-patient diagnostic costs of Immediate ICM insertion prior to discharge versus using a wearable monitor followed by ICM in patients with ESUS, from Medicare and patient out-of-pocket perspectives. Similar modeling strategy and cost analysis was applied to the Stroke AF and Per Diem trials. Results: In 192 ESUS patients, AF detection increased with length of monitoring: 7.3 % at 14 days, 9.4 % at 30 days, and 17.2 % after a median ~ 6 months (189 days). Cost modeling predicted that immediate ICM leads to $3683-$4070 lower Medicare payments per-patient and $1425-$1503 lower patient out-of-pocket costs compared to Wearable-to-ICM strategies. Using similar modeling in the PER DIEM and STROKE AF trials, the additive costs of the 30-day ELR to ICM strategy ranged from $3786-$3946 from a payer perspective and $1472-$1503 from a patient out-of-pocket perspective. Conclusions: Use of ICM immediately after ESUS is cost-saving compared to Wearable-to-ICM strategies, due to the cost and low diagnostic yield of short-term wearable cardiac monitoring.

4.
Cureus ; 13(3): e14049, 2021 Mar 22.
Article in English | MEDLINE | ID: mdl-33898135

ABSTRACT

A 42-year-old woman with a remote history of smoking and recently diagnosed anorectal cancer presented with typical anginal chest pain, dyspnea, palpitations, and hallucinations. She was started on continuous 5-flurouracil (5-FU) infusion five days before presentation. Her physical examination was significant for bilateral bibasilar crackles and tachycardia. Her bloodwork was significant for an increased troponin and brain natriuretic peptide (BNP). Electrocardiogram (EKG) showed sinus tachycardia with ST elevation in multiple contiguous leads, whereas transthoracic echocardiogram (TTE) showed estimated ejection fraction of 17% with severe global hypokinesis with apical akinesis and matted thrombus at the apex. Coronary angiogram showed 20% occlusion of the left anterior descending artery. She was diagnosed with 5-FU induced Takotsubo cardiomyopathy complicated by left ventricular (LV) thrombosis. 5-FU was discontinued, uridine triacetate was given as reversal agent. Aspirin and apixaban were started for three months for LV thrombosis. Her six-week TTE showed return of normal heart function with resolution of LV thrombosis.

SELECTION OF CITATIONS
SEARCH DETAIL
...