1.
J Indian Soc Pedod Prev Dent ; 33(4): 302-6, 2015.
Article in English | MEDLINE | ID: mdl-26381632

ABSTRACT

BACKGROUND: The most vulnerable tooth is the maxillary incisor, which sustains 80% of dental injuries. Dynamic Finite element analysis is used to understand the biomechanics of fracture of maxillary incisor under traumatic impact loading. AIM: The aim was to investigate the stress patterns of an upper incisor in a three-dimensional (3D) model under traumatic impact loading in various directions. MATERIALS AND METHODS: A 3D finite element model of the upper incisor and surrounding tissues was established. A sinusoidal force of 800N was applied over a period of 4 ms. RESULTS: Software performs a series of calculations and mathematical equations and yields the simulation results. During the horizontal impact (F1), stresses were concentrated in the cervical area of the crown, reaching peak stress of 125 MPa at 2 ms. CONCLUSION: A horizontal force exerted on the labial surface of the tooth tends to cause cervical crown fractures, oblique crown root fractures, and oblique root fractures.


Subject(s)
Finite Element Analysis , Incisor/injuries , Biomechanical Phenomena , Computer Simulation , Dental Stress Analysis , Humans , Maxilla , Software , Stress, Mechanical
2.
J Int Oral Health ; 5(4): 26-9, 2013 Aug.
Article in English | MEDLINE | ID: mdl-24155616

ABSTRACT

BACKGROUND: The purpose of this study was to compare the shear and tensile bond strength of three adhesive systems with increasing concentrations of filler for bonding brackets. MATERIALS & METHODS: The study was carried out on 120 extracted human premolars; randomly divided into six groups, three groups for shear bond strength & three for tensile bond strength, each subgroup consisting of 20 teeth; using light cured adhesive systems: Group 1: FORTIFY Unfilled, (unfilled penetrating resin) Group 2: ALITEF Low Filled (filler load 58% by weight) Group 3: PYRAMID Highly Filled (filler load greater than 80% by weight) with metal brackets (TP 256-650. TP orthodontic inc. Po.box 73,La Porte 46350,USA). RESULTS: The findings showed that in vitro tensile bond strength and shear bond strength of PYRAMID [9.88/11.46 MPa resp.] is significantly greater than ALITEFLO[5.34/9.50 MPa resp.] and FORTIFY [2.65/5.39 MPa resp.]. CONCLUSION: Using the same bracket and force mode but different adhesive filler concentrations revealed increased shear and tensile bond strength with increased filler concentration. How to cite this article: Kumar PS, Patil C, Hullal B, Putturaj KT, Sangolgi VC, Jayasudha K. A Comparative Study of the Shear and Tensile Bond Strength using three types of Direct Bonding Adhesives on Stainless Steel Brackets - An In Vitro Study. J Int Oral Health 2013; 5(4):26-29.

SELECTION OF CITATIONS
SEARCH DETAIL
...