Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Acta Oncol ; 57(10): 1359-1366, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30004264

ABSTRACT

BACKGROUND: The aim of the present study was to verify the dosimetric accuracy of two-dimensional (2D) in vivo rectal dosimetry using an endorectal balloon (ERB) with unfoldable EBT3 films for high-dose-rate (HDR) brachytherapy for cervical cancer. The clinical applicability of the technique was discussed. MATERIAL AND METHODS: ERB inflation makes the EBT3 films unrolled, whereas its deflation makes them rolled. Patient-specific quality assurance (pQA) tests were performed in 20 patient plans using an Ir-192 remote afterloading system and a water-filled cervical phantom with the ERB. The dose distributions measured in ERBs were compared with those of the treatment plans. RESULTS: The absolute dose profiles measured by the ERBs were in good agreement with those of treatment plans. The global gamma passing rates were 96-100% and 91-100% over 20 pQAs under the criteria of 3%/3 mm and 3%/2 mm, respectively, with a 30% low-dose threshold. Dose-volume histograms of the rectal wall were obtained from the measured dose distributions and showed small volume differences less than 2% on average from the patients' plans over the entire dose interval. The positioning error of the applicator set was detectable with high sensitivity of 12% dose area variation per mm. Additionally, the clinical applicability of the ERB was evaluated in volunteers, and none of them felt any pain when the ERB was inserted or removed. CONCLUSIONS: The 2D in vivo rectal dosimetry using the ERB with EBT3 films was effective and might be clinically applicable for HDR brachytherapy for cervical and prostate cancers to monitor treatment accuracy and consistency as well as to predict rectal toxicity.


Subject(s)
Brachytherapy/methods , Rectum/radiation effects , Uterine Cervical Neoplasms/radiotherapy , Female , Humans , Phantoms, Imaging , Radiotherapy Dosage
2.
Radiother Oncol ; 120(2): 327-32, 2016 08.
Article in English | MEDLINE | ID: mdl-27222297

ABSTRACT

BACKGROUND AND PURPOSE: The present study aims to investigate the feasibility of two-dimensional (2D) in vivo rectal dosimetry using an endorectal balloon for the radiotherapy of prostate cancer. MATERIALS AND METHODS: The endorectal balloon was equipped with an unfoldable radiochromic film. The film was unrolled as the balloon was inflated, and rolled as it was deflated. Its mechanical and imaging properties were tested, and the dosimetric effectiveness was evaluated in clinical photon and proton beams. RESULTS: The size of the endorectal balloon including the film was linearly proportional to the volume of water filled in the balloon, and its position could be identified by X-ray radiography. The loss of dose information due to film cutting was within ±1mm from the cutting line. Applying linear interpolation on cut film, the gamma passing rate was more than 95% for 2%/2mm criteria. The measured dose profiles agreed with the plan within 3% and 4% for the photon and proton beams, respectively. A dose-volume histogram of the anterior rectal wall could be obtained from the measured dose distribution in the balloon, which also agreed well with the plan. CONCLUSIONS: 2D in vivo rectal dosimetry is feasible using the endorectal balloon with a radiochromic film in the radiotherapy of prostate cancer.


Subject(s)
In Vivo Dosimetry/methods , Prostatic Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Rectum/diagnostic imaging , Rectum/radiation effects , Film Dosimetry , Humans , Male , Prostatic Neoplasms/pathology , Rectum/pathology
SELECTION OF CITATIONS
SEARCH DETAIL
...