Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Ann Pharm Fr ; 2024 May 31.
Article in English | MEDLINE | ID: mdl-38823440

ABSTRACT

A sensitive and accurate LC/MS method for the determination of elbasvir (ELB) and grazoprevir (GZP) in human plasma was established using daclatasvir (DCT) as an internal standard. The analytes were separated on a Waters Spherisorb phenyl column (150mm×4.6mm ID, 5µm particle size) maintained at 40°C±2°C. Gradient elution, at a flow rate of 0.8mLmin-1, was used. The mobile phase consists of 90% of acetonitrile mixed to 10% of a 5mM ammonium formate buffer (+0.1% v/v of trimethylamine, pH was adjusted to 3.2 by formic acid) as phase A and 10% of acetonitrile mixed to 90% of the same buffer as phase B. Liquid-liquid extraction with ethyl acetate solvent was used to recuperate compounds from plasma. The method was validated over a concentration range of 2 and 100ng/mL for GZP and between 1 and 50ng/mL for ELB. The intra- and inter-day precision and accuracy of the quality control samples at low, medium, and high concentration levels exhibited relative standard deviations (RSD)<15%, and the accuracy values ranged from 94.2 to 107.8%. The robustness of the method was established using a two-level full factorial design.

2.
Int J Anal Chem ; 2019: 9685750, 2019.
Article in English | MEDLINE | ID: mdl-31511775

ABSTRACT

A sensitive, precise, accurate, and specific isocratic reversed-phase high-performance liquid chromatographic (RP-HPLC) method for the simultaneous separation and determination of zolmitriptan, naratriptan, dihydroergotamine, ketotifen, and pizotifen in pharmaceutical formulations has been developed and validated. An experimental design was applied for the optimization of the chromatographic parameters. A two-level full factorial 2 k was used for studying the interaction between the variables to be optimized: the percentage of acetonitrile in the mobile phase, mobile-phase pH, nature of the buffer, and column oven temperature. The most significant parameters are the percentage of acetonitrile and the mobile-phase pH. These significant parameters were optimized using the Doehlert matrix. The optimum separation was achieved by means of a Waters XBridge C18 column (250 mm × 4.6 mm, 5 µm) with a mobile phase consisting of acetonitrile and a 10 mM sodium perchlorate buffer (38 : 62, v/v) at a flow rate of 1.0 mL·min-1 and UV detection at 220 nm. The selectivity, method linearity, accuracy, and precision were examined as part of the method validation. The described method shows excellent linearity over a range of 30 to 70 µg·mL-1 for all compounds with correlation coefficients higher than 0.995. The standard deviations of the intraday and interday precision were between 0.75 and 1.94%. The validated method was successfully applied to perform routine analysis of these compounds in different pharmaceutical products such as syrups and tablets. In the presence of some preservatives, it was found that there were no peaks at the related peak locations.

SELECTION OF CITATIONS
SEARCH DETAIL
...