Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Malays J Pathol ; 43(2): 281-290, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34448792

ABSTRACT

INTRODUCTION: Serum protein electrophoresis (SPE) is a well-established laboratory technique. However, reporting of results varies considerably between laboratories. The variation in reporting can cause confusion to the clinician with a potential of adversely impacting patient care. The purpose of the survey was to find out the variation in reporting and to prepare recommendations to the Malaysian laboratories based on the survey to reduce both the variation in reporting between laboratories and the risk of misinterpretation of reports. MATERIALS AND METHODS: To determine the extent of variation in reporting of protein electrophoresis results questionnaires were distributed to the pathologists of various laboratories in Malaysia regarding the method, quantification of paraprotein concentrations and immunoglobulin assays, and information regarding current laboratory electrophoresis practices. RESULTS: Variation was found in the following reporting practices: (a) screening protocol; (b) reporting of serum albumin; (c) numerical reporting of protein fractions and paraprotein; (d) co-migration of a paraprotein with a normal serum protein; (e) reporting of multiple paraprotein bands (f) appearance of small abnormal band and oligoclonal bands and (g) communication about of interferences. CONCLUSION: The pathologists of the country made recommendations on the reporting of protein electrophoresis. Harmonised reporting will reduce inconsistency, variation in reporting, improve the quality of the report and most importantly improve patient care.


Subject(s)
Electrophoresis , Blood Proteins , Humans , Malaysia , Paraproteins , Surveys and Questionnaires
2.
Article in English | MEDLINE | ID: mdl-17121310

ABSTRACT

There is very little data regarding the factors related to intima-media thickness (IMT) of the common carotid artery in normal individuals in those with non-insulin diabetes mellitus and perimenopausal women in Southeast Asian countries. Ultrasound imaging evaluating the carotid artery IMT in those with diabetes and those on hormone replacement therapy (HRT) was performed beginning in August 2000 for a period of nearly two years at the Department of Radiology, Hospital Universiti Sains Malaysia, Kubang Kerian, Kelantan, Malaysia. A total of 153 participants were included. Significant differences between the women on HRT and not on HRT were IMT and systolic blood pressure. When comparing those with non-insulin dependent diabetes mellitus (NIDDM) and normal individuals, the significant differences were IMT, total cholesterol level, systolic blood pressure and diastolic blood pressure. IMT was high in those with NIDDM but not in those on HRT. Both those with NIDDM and those on HRT had associated dyslipidemia and systolic hypertension.


Subject(s)
Carotid Artery, Common/diagnostic imaging , Diabetes Mellitus, Type 2/pathology , Hormone Replacement Therapy , Perimenopause/physiology , Tunica Intima/diagnostic imaging , Blood Pressure , Cholesterol/blood , Cross-Sectional Studies , Female , Humans , Malaysia , Middle Aged , Ultrasonography
SELECTION OF CITATIONS
SEARCH DETAIL
...