Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Cardiovasc Revasc Med ; 18(3): 160-164, 2017.
Article in English | MEDLINE | ID: mdl-28017259

ABSTRACT

BACKGROUND: Procedural and clinical outcomes in patients with very long (>30mm) coronary lesions who underwent stent-based percutaneous coronary interventions are still unfavorable. Therefore, we compared the relative efficacy and safety of resolute zotarolimus-eluting stents (R-ZES) and Xpedition everolimus-eluting stents (X-EES) for patients with de novo very long coronary lesions. METHODS: This comparative single-centre, retrospective study compared long R-ZES and X-EES in consecutive patients admitted with very long (≥30mm) native ACC/AHA type C coronary lesions in 2014. All patients were followed up clinically at 1, 3, 6 and 12months. In this study, only symptom-driven angiogram was advised. The study end point was to evaluate immediate procedural success and one-year rate of target lesion failure (TLF), which is a composite of cardiac death, target lesion myocardial infarction, or target lesion revascularization (TLR). RESULTS: Total number of patients enrolled in this study was 185 (R-ZES=107; X-EES=78). The baseline characteristics and post procedural success rate were similar between R-ZES and X-EES groups, including the post stenting lesion lengths (36.6±1.92mm vs 40.71±6.175mm, P=0.09). At 12-month follow-up, there were no significant between-group differences in the rate of adverse clinical events (death, myocardial infarction, stent thrombosis, target lesion revascularization, and composite outcomes). Procedural success was achieved in 94% in R-ZES group and 93% in X-EES group (P=0.24). The incidence of TLF was 5% in R-ZES and 4% in X-EES groups (HR-1.25; 95% CI-0.86-5.6; P=0.19). CONCLUSION: Patients with de novo long coronary artery disease, R-ZES implantation showed similar clinical outcome as compared with X-EES implantation.


Subject(s)
Cardiovascular Agents/administration & dosage , Coronary Stenosis/therapy , Drug-Eluting Stents , Everolimus/administration & dosage , Percutaneous Coronary Intervention/instrumentation , Sirolimus/analogs & derivatives , Aged , Cardiovascular Agents/adverse effects , Coronary Angiography , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/mortality , Everolimus/adverse effects , Female , Humans , India , Kaplan-Meier Estimate , Male , Middle Aged , Myocardial Infarction/etiology , Percutaneous Coronary Intervention/adverse effects , Proportional Hazards Models , Prosthesis Design , Retrospective Studies , Risk Factors , Sirolimus/administration & dosage , Sirolimus/adverse effects , Time Factors , Treatment Outcome
2.
Indian Heart J ; 68 Suppl 2: S276-S279, 2016 Sep.
Article in English | MEDLINE | ID: mdl-27751314

ABSTRACT

Thirty-nine year male had a history of road traffic accident with polytrauma. At emergency room he started having chest pain with ventricular tachycardia. He was subsequentially diagnosed with right coronary artery dissection secondary to blunt trauma which is an extremely rare cause of inferior wall myocardial infarction. After some dilemmas, he was ultimately treated with intravascular ultrasound guided coronary angioplasty with stenting and had an uneventful recovery.


Subject(s)
Aortic Dissection/complications , Coronary Aneurysm/complications , Coronary Vessels/injuries , Disease Management , Inferior Wall Myocardial Infarction/etiology , Thoracic Injuries/complications , Wounds, Nonpenetrating/complications , Adult , Aortic Dissection/diagnosis , Aortic Dissection/surgery , Angioplasty, Balloon, Coronary/methods , Coronary Aneurysm/diagnosis , Coronary Aneurysm/surgery , Coronary Angiography , Coronary Vessels/diagnostic imaging , Diagnosis, Differential , Electrocardiography , Humans , Inferior Wall Myocardial Infarction/diagnosis , Male , Stents , Thoracic Injuries/diagnosis , Ultrasonography, Interventional , Wounds, Nonpenetrating/diagnosis
SELECTION OF CITATIONS
SEARCH DETAIL
...