Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
Add more filters










Publication year range
1.
Materials (Basel) ; 17(11)2024 Jun 05.
Article in English | MEDLINE | ID: mdl-38894016

ABSTRACT

We investigated micro-threaded stem taper surface and its impact on premature failures, aseptic loosening, and infection in cementless hip endoprostheses. Our study focused on the fretting, and crevice corrosion of micro-threaded tapers, as well as the characterization of the microstructure and surface properties of two new and three retrieved Zweymüller stem tapers. The retrieved samples were selected and examined based on the head-stem taper interface being the sole source of modularity with a metallic component, specifically between the Ti alloy taper stem and the ceramic head. To determine the surface chemistry and microstructures of both new and retrieved hip endoprostheses stem taper titanium alloy, scanning -electron microscopy (SEM) was employed for morphological and microstructural analyses. Energy dispersive spectroscopy (EDS) was utilized for characterizing chemical element distribution, and electron backscattered diffraction (EBSD) was used for phase analysis. The roughness of the micro-threated stem tapers from different manufacturers was investigated using an optical profilometer, with standard roughness parameters Ra (average surface roughness) and Rz (mean peak to valley height of the roughness profile) being measured. Electrochemical studies revealed no fretting corrosion in retrieved stem tapers with ceramic heads. Consequently, three retrieved tapers and two new ones for comparison underwent potentiodynamic measurements in Hank's solution to determine the corrosion rate of new and retrieved stem taper surfaces. The results showed a low corrosion rate for both new and prematurely failed retrieved samples due to aseptic loosening. However, the corrosion rate was higher in infected and low-grade infected tapers. In conclusion, our study suggests that using ceramic heads reduces taper corrosion and subsequently decreases the incidence of premature failures in total hip arthroplasty.

2.
Materials (Basel) ; 16(21)2023 Oct 26.
Article in English | MEDLINE | ID: mdl-37959464

ABSTRACT

For the improvement of surface roughness, titanium joint arthroplasty (TJA) components are grit-blasted with Al2O3 (corundum) particles during manufacturing. There is an acute concern, particularly with uncemented implants, about polymeric, metallic, and corundum debris generation and accumulation in TJA, and its association with osteolysis and implant loosening. The surface morphology, chemistry, phase analysis, and surface chemistry of retrieved and new Al2O3 grit-blasted titanium alloy were determined with scanning electron microscopy (SEM), X-ray energy-dispersive spectroscopy (EDS), transmission electron microscopy (TEM), X-ray photoelectron spectroscopy (XPS) and confocal laser fluorescence microscopy, respectively. Peri-prosthetic soft tissue was studied with histopathology. Blasted retrieved and new stems were exposed to human mesenchymal stromal stem cells (BMSCs) for 7 days to test biocompatibility and cytotoxicity. We found metallic particles in the peri-prosthetic soft tissue. Ti6Al7Nb with the residual Al2O3 particles exhibited a low cytotoxic effect while polished titanium and ceramic disks exhibited no cytotoxic effect. None of the tested materials caused cell death or even a zone of inhibition. Our results indicate a possible biological effect of the blasting debris; however, we found no significant toxicity with these materials. Further studies on the optimal size and properties of the blasting particles are indicated for minimizing their adverse biological effects.

3.
Materials (Basel) ; 16(9)2023 Apr 22.
Article in English | MEDLINE | ID: mdl-37176169

ABSTRACT

We studied inflammatory and oxidative stress-related parameters and cytotoxic response of human umbilical vein endothelial cells (HUVEC) to a 24 h treatment with milled particles simulating debris involved in sandblasting of orthopedic implants (OI). We used different abrasives (corundum-(Al2O3), used corundum retrieved from removed OI (u. Al2O3), and zirconia/silica composite (ZrO2/SiO2)). Morphological changes were observed by scanning electron microscopy (SEM). Concentration of Interleukins IL-6 and IL-1ß and Tumor Necrosis Factor α (TNF)-α was assessed by enzyme-linked immunosorbent assay (ELISA). Activity of Cholinesterase (ChE) and Glutathione S-transferase (GST) was measured by spectrophotometry. Reactive oxygen species (ROS), lipid droplets (LD) and apoptosis were measured by flow cytometry (FCM). Detachment of the cells from glass and budding of the cell membrane did not differ in the treated and untreated control cells. Increased concentration of IL-1ß and of IL-6 was found after treatment with all tested particle types, indicating inflammatory response of the treated cells. Increased ChE activity was found after treatment with u. Al2O3 and ZrO2/SiO2. Increased GST activity was found after treatment with ZrO2/SiO2. Increased LD quantity but not ROS quantity was found after treatment with u. Al2O3. No cytotoxicity was detected after treatment with u. Al2O3. The tested materials in concentrations added to in vitro cell lines were found non-toxic but bioactive and therefore prone to induce a response of the human body to OI.

4.
Sci Rep ; 7: 42234, 2017 02 07.
Article in English | MEDLINE | ID: mdl-28169377

ABSTRACT

While a lot is known about the deformation of metallic surfaces from experiments, elasticity theory and simulations, this investigation represents the first molecular-dynamics-based simulation of uniaxial deformation for the vicinal surfaces in a comparison of copper and nickel. These vicinal surfaces are composed of terraces divided by equidistant, mono-atomic steps. The periodicity of vicinals makes them good candidates for the study of the surface steps' influences on surface dynamics. The simulations of tensile and compressive uniaxial deformations were performed for the (1 1 19) vicinal surfaces. Since the steps on the surfaces serve as stress concentrators, the first defects were expected to nucleate here. In the case of copper, this was found to be the case. In the case of nickel, however, dislocations nucleated beneath the near-surface layer affected by the displacement field generated by the steps. Slip was hindered at the surface step by the vortex in the displacement field. The differences in the deformation mechanisms for the Ni(1 1 19) and Cu(1 1 19) surfaces can be linked to the differences in their displacement fields. This could lead to novel bottom-up approaches to the nanostructuring of surfaces using strain.

5.
Lab Chip ; 14(22): 4329-33, 2014 Nov 21.
Article in English | MEDLINE | ID: mdl-25231831

ABSTRACT

Reliable, autonomous, internally self-powered microfluidic pumps are in critical demand for rapid point-of-care (POC) devices, integrated molecular-diagnostic platforms, and drug delivery systems. Here we report on a Self-powered Imbibing Microfluidic Pump by Liquid Encapsulation (SIMPLE), which is disposable, autonomous, easy to use and fabricate, robust, and cost efficient, as a solution for self-powered microfluidic POC devices. The imbibition pump introduces the working liquid which is sucked into a porous material (paper) upon activation. The suction of the working liquid creates a reduced pressure in the analytical channel and induces the sequential sample flow into the microfluidic circuits. It requires no external power or control and can be simply activated by a fingertip press. The flow rate can be programmed by defining the shape of utilized porous material: by using three different paper shapes with circular section angles 20°, 40° and 60°, three different volume flow rates of 0.07 µL s(-1), 0.12 µL s(-1) and 0.17 µL s(-1) are demonstrated at 200 µm × 600 µm channel cross-section. We established the SIMPLE pumping of 17 µL of sample; however, the sample volume can be increased to several hundreds of µL. To demonstrate the design, fabrication, and characterization of SIMPLE, we used a simple, robust and cheap foil-laminating fabrication technique. The SIMPLE can be integrated into hydrophilic or hydrophobic materials-based microfluidic POC devices. Since it is also applicable to large-scale manufacturing processes, we anticipate that a new chapter of a cost effective, disposable, autonomous POC diagnostic chip is addressed with this technical innovation.


Subject(s)
Microfluidic Analytical Techniques/instrumentation , Equipment Design , Hydrophobic and Hydrophilic Interactions , Microfluidic Analytical Techniques/economics , Paper , Point-of-Care Systems/economics , Porosity
6.
Biomed Mater ; 5(4): 045012, 2010 Aug.
Article in English | MEDLINE | ID: mdl-20683125

ABSTRACT

The total replacement of joints by the implantation of permanently indwelling prosthetic components has been one of the major successes of modern surgery in terms of relieving pain and correcting deformity. However, the aseptic loosening of a prosthetic-joint component is the most common reason for joint-revision surgery. Furthermore, it is thought that wear particles are one of the major contributors to the development and perpetuation of aseptic loosening. The aim of the present study was to identify the factors related to the aseptic loosening of an AISI 316L stainless steel total hip prosthesis. The stem was evaluated by x-ray photoelectron spectroscopy, with polished and rough regions being analyzed in order to establish the differences in the chemical compositions of both regions. Specific areas were examined using scanning electron microscopy with energy dispersive x-ray spectroscopy and light microscopy.


Subject(s)
Hip Joint/pathology , Hip Prosthesis/adverse effects , Joint Instability/etiology , Joint Instability/pathology , Prosthesis-Related Infections/etiology , Prosthesis-Related Infections/pathology , Stainless Steel/adverse effects , Equipment Failure Analysis , Hip Joint/drug effects , Hip Joint/surgery , Humans , Male , Middle Aged
7.
Protoplasma ; 241(1-4): 83-9, 2010 May.
Article in English | MEDLINE | ID: mdl-20155290

ABSTRACT

The structure of the digestive gland epithelium of a terrestrial isopod Porcellio scaber has been investigated by conventional scanning electron microscopy (SEM), focused ion beam-scanning electron microscopy (FIB/SEM), and light microscopy in order to provide evidence on morphology of the gland epithelial surface in animals from a stock culture. We investigated the shape of cells, extrusion of lipid droplets, shape and distribution of microvilli, and the presence of bacteria on the cell surface. A total of 22 animals were investigated and we found some variability in the appearance of the gland epithelial surface. Seventeen of the animals had dome-shaped digestive gland "normal" epithelial cells, which were densely and homogeneously covered by microvilli and varying proportions of which extruded lipid droplets. On the surface of microvilli we routinely observed sparsely distributed bacteria of different shapes. Five of the 22 animals had "abnormal" epithelial cells with a significantly altered shape. In three of these animals, the cells were much smaller, partly or completely flat or sometimes pyramid-like. A thick layer of bacteria was detected on the microvillous border, and in places, the shape and size of microvilli were altered. In two animals, hypertrophic cells containing large vacuoles were observed indicating a characteristic intracellular infection. The potential of SEM in morphological investigations of epithelial surfaces is discussed.


Subject(s)
Digestive System/ultrastructure , Epithelium/ultrastructure , Isopoda/ultrastructure , Microscopy, Electron, Scanning/methods , Animals , Hepatopancreas/ultrastructure
8.
Acta Biomater ; 6(1): 308-17, 2010 Jan.
Article in English | MEDLINE | ID: mdl-19540942

ABSTRACT

Cu-Al-Ni shape memory alloys (SMAs) have been investigated as materials for medical devices, but their biomedical application is still limited. The aim of this work was to compare the microstructure, corrosion and cytotoxicity in vitro of a Cu-Al-Ni SMA. Rapidly solidified (RS) thin ribbons, manufactured via melt spinning, were used for the tests. The control alloy was a permanent mould casting of the same composition, but without shape memory effect. The results show that RS ribbons are significantly more resistant to corrosion compared with the control alloy, as judged by the lesser release of Cu and Ni into the conditioning medium. These results correlate with the finding that RS ribbons were not cytotoxic to L929 mouse fibroblasts and rat thymocytes. In addition, the RS ribbon conditioning medium inhibited cellular proliferation and IL-2 production by activated rat splenocytes to a much lesser extent. The inhibitory effects were almost completely abolished by conditioning the RS ribbons in culture medium for 4 weeks. Microstructural analysis showed that RS ribbons are martensitic, with boron particles as a minor phase. In contrast, the control Cu-Al-Ni alloy had a complex multiphase microstructure. Examination of the alloy surfaces after conditioning by energy dispersive X-ray and Auger electron spectroscopy showed the formation of Cu and Al oxide layers and confirmed that the metals in RS ribbons are less susceptible to oxidation and corrosion compared with the control alloy. In conclusion, these results suggest that rapid solidification significantly improves the corrosion stability and biocompatibility in vitro of Cu-Al-Ni SMA ribbons.


Subject(s)
Alloys/chemistry , Aluminum/chemistry , Biocompatible Materials/chemistry , Copper/chemistry , Dental Alloys/chemistry , Nickel/chemistry , Animals , Apoptosis , Cell Survival , Corrosion , Male , Mice , Oxygen/chemistry , Rats , Spleen/cytology , Surface Properties , Tetrazolium Salts/chemistry , Thiazoles/chemistry , Thymus Gland/cytology
9.
Biofouling ; 25(6): 481-93, 2009.
Article in English | MEDLINE | ID: mdl-19373571

ABSTRACT

Fouling-release coatings were prepared from blends of a fluorinated/siloxane copolymer with a poly(dimethyl siloxane) (PDMS) matrix in order to couple the low modulus character of PDMS with the low surface tension typical for fluorinated polymers. The content of the surface-active copolymer was varied in the blend over a broad range (0.15-10 wt % with respect to PDMS). X-ray photoelectron spectroscopy depth profiling analyses were performed on the coatings to establish the distribution of specific chemical constituents throughout the coatings, and proved enrichment in fluorine of the outermost layers of the coating surface. Addition of the fluorinated/siloxane copolymer to the PDMS matrix resulted in a concentration-dependent decrease in settlement of barnacle, Balanus amphitrite, cyprids. The release of young plants of Ulva, a soft fouling species, and young barnacles showed that adhesion strength on the fluorinated/siloxane copolymer was significantly lower than the siloxane control. However, differences in adhesion strength were not directly correlated with the concentration of copolymer in the blends.


Subject(s)
Fluorine , Polymers , Siloxanes , Thoracica/drug effects , Ulva/drug effects , Adhesiveness , Animals , Dimethylpolysiloxanes/chemical synthesis , Dimethylpolysiloxanes/chemistry , Dimethylpolysiloxanes/pharmacology , Fluorine/chemistry , Fluorine/pharmacology , Polymers/chemical synthesis , Polymers/chemistry , Polymers/pharmacology , Siloxanes/chemistry , Siloxanes/pharmacology , Surface Properties , Thoracica/physiology , Ulva/physiology
10.
Biofouling ; 25(1): 55-67, 2009.
Article in English | MEDLINE | ID: mdl-18855197

ABSTRACT

SiO(x)-like coatings were deposited on glass slides from a hexamethylsiloxane precursor by plasma-assisted CVD (PACVD). Surface energies (23.1-45.7 mJ m(-1)) were correlated with the degree of surface oxidation and hydrocarbon contents. Tapping mode AFM revealed a range of surface topologies with Ra values 1.55-3.16 nm and RMS roughness 1.96-4.11 nm. Settlement of spores of the green alga Ulva was significantly less, and detachment under shear significantly more on the lowest surface energy coatings. Removal of young plants (sporelings) of Ulva under shear was positively correlated with reducing the surface energy of the coatings. The most hydrophobic coatings also showed good performance against a freshwater bacterium, Pseudomonas fluorescens, significantly reducing initial attachment and biofilm formation, and reducing the adhesion strength of attached bacterial cells under shear. Taken together the results indicate potential for further investigation of these coatings for applications such as heat exchangers and optical instruments.


Subject(s)
Bacteria/drug effects , Bacteria/growth & development , Biofilms/drug effects , Biofilms/growth & development , Eukaryota/drug effects , Eukaryota/growth & development , Silicon Dioxide/pharmacology , Water Microbiology , Bacteria/classification , Diatoms/drug effects , Diatoms/growth & development , Dimethylpolysiloxanes/chemistry , Eukaryota/classification , Glass , Halomonadaceae/drug effects , Halomonadaceae/growth & development , Hydrophobic and Hydrophilic Interactions , Marinobacter/drug effects , Marinobacter/growth & development , Nanostructures , Pseudomonas fluorescens/drug effects , Pseudomonas fluorescens/growth & development , Spores/growth & development , Spores, Bacterial/drug effects , Spores, Bacterial/growth & development , Surface Properties , Ulva/drug effects , Ulva/growth & development , Volatilization
11.
J Hazard Mater ; 109(1-3): 59-70, 2004 Jun 18.
Article in English | MEDLINE | ID: mdl-15177746

ABSTRACT

In order to make a complete characterization of electric-arc furnace (EAF) dust, as hazardous industrial waste, and to solve its permanent disposal and/or recovery, bearing in mind both the volumes formed in the Croatian steel industry and experiences of developed industrial countries, a study of its properties was undertaken. For this purpose, samples of EAF dust, taken from the regular production process in the Zeljezara Sisak Steel Mill between December 2000 and December 2001, were subjected to a series of tests. The chemical composition of EAF dust samples was investigated by means of a several different analytical methods. The results from the chemical analysis show that the approximate order of abundance of major elements in EAF dusts is as follows: Fe, Zn, Mn, Ca, Mg, Si, Pb, S, Cr, Cu, Al, C, Ni, Cd, As and Hg. Granular-metric composition of single samples was determined by applying sieve separation. Scanning electron micro-structural examination of EAF dust microstructure was performed and results indicated that all twelve EAF dusts were composed of solid spherical agglomerates with Fe, Zn, Pb, O, Si and Ca as the principal element. The investigation of grain morphology and the mineralogical composition of EAF dust were taken by combination of high resolution Auger electron spectroscopy (HR AES), X-ray photoelectron spectroscopy (XPS) and X-ray powder diffraction analysis. The analysis of XPS-spectra determined the presence of zinc in the form of ZnO phase and the presence of lead in the form of PbO phase, i.e. PbSO3/PbSO4 forms. The results of the X-ray diffraction phase analysis show that the basis of the examined EAF dust samples is made of a mixture of metal oxides, silicates and sulphates. The metal concentration, anions, pH value and conductivity in water eluates was determined in order to define the influence of EAF dust on the environment.


Subject(s)
Dust/analysis , Industrial Waste/analysis , Steel/analysis , Electricity , Metals, Heavy/analysis
SELECTION OF CITATIONS
SEARCH DETAIL
...