Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Resuscitation ; 198: 110171, 2024 May.
Article in English | MEDLINE | ID: mdl-38461889

ABSTRACT

BACKGROUND: Foreign body airway obstruction (FBAO) stands as an important contributor to accidental fatalities, yet prompt bystander interventions have been shown to improve survival. This study aimed to evaluate the incidence, interventions, and survival outcomes of patients with out-of-hospital cardiac arrest (OHCA) related to FBAO in comparison to patients with non-FBAO OHCA. METHODS: In this population-based cohort study, we included all OHCAs in Denmark from 2016 to 2022. Cases related to FBAO were identified and linked to the patient register. Descriptive and multivariable analyses were performed to evaluate prognostic factors potentially influencing survival. RESULTS: A total of 30,926 OHCA patients were included. The incidence rate of FBAO-related OHCA was 0.78 per 100,000 person-years. Among FBAO cases, 24% presented with return of spontaneous circulation upon arrival of the emergency medical services. The 30-day survival rate was higher in FBAO patients (30%) compared to non-FBAO patients (14%). Bystander interventions were recorded in 26% of FBAO cases. However, no statistically significant association between bystander interventions or EMS personnels' use of Magill forceps and survival was shown, aOR 1.47 (95 % CI 0.6-3.6) and aOR 0.88 (95% CI 0.3-2.1). CONCLUSION: FBAO-related OHCA was rare but has a higher initial survival rate than non-FBAO related OHCA, with a considerable proportion of patients achieving return of spontaneous circulation upon arrival of the emergency medical service personnel. No definitive associations were established between survival and specific interventions performed by bystanders or EMS personnel. These findings highlight the need for further research in this area.


Subject(s)
Airway Obstruction , Cardiopulmonary Resuscitation , Emergency Medical Services , Foreign Bodies , Out-of-Hospital Cardiac Arrest , Humans , Out-of-Hospital Cardiac Arrest/therapy , Out-of-Hospital Cardiac Arrest/mortality , Out-of-Hospital Cardiac Arrest/epidemiology , Out-of-Hospital Cardiac Arrest/etiology , Denmark/epidemiology , Male , Female , Incidence , Aged , Middle Aged , Airway Obstruction/epidemiology , Airway Obstruction/etiology , Airway Obstruction/therapy , Airway Obstruction/mortality , Emergency Medical Services/statistics & numerical data , Emergency Medical Services/methods , Cardiopulmonary Resuscitation/statistics & numerical data , Cardiopulmonary Resuscitation/methods , Foreign Bodies/complications , Foreign Bodies/epidemiology , Registries , Survival Rate/trends , Aged, 80 and over , Adult , Cohort Studies
2.
Int Urogynecol J ; 31(3): 643-649, 2020 03.
Article in English | MEDLINE | ID: mdl-31278414

ABSTRACT

INTRODUCTION: Vaginal birth increases the risk of urinary retention and overdistention of the bladder. To avoid unnecessary discomfort by catheterization, it is preferable to use ultrasound for diagnosis of these conditions. The aim of this study was to determine the validity of transabdominal ultrasound and a portable ultrasound system, Biocon-700, to measure bladder volume in women postpartum. METHODS: Fifty women were included in this method comparison study. Within 48 h of giving birth, their bladder volume was measured in randomized order with both transabdominal ultrasound and Biocon-700. After urination, participants were scanned with Biocon-700 to measure residual bladder volume, and finally the bladder was emptied by catheterization. The total bladder volume was calculated as the voided volume plus the catheterized volume. RESULTS: Biocon-700 measured 43.4 ml ± 117.4 ml (mean ± SD) lower than the total bladder volume, while volumes measured by transabdominal ultrasound were 117.8 ml ± 110.0 ml (mean ± SD) lower. Linear regression showed significant proportional bias in both methods. The Biocon-700 could detect a residual bladder volume > 150 ml with a positive predictive value of 66.7% and a negative predictive value of 100%. CONCLUSIONS: Neither transabdominal ultrasound nor the portable ultrasound system, Biocon-700, can be used to measure bladder volume precisely after vaginal delivery. However, both ultrasound methods can be used as screening tools to prevent overdistention of the bladder, and Biocon-700 can furthermore be used to screen women for a residual bladder volume > 150 ml.


Subject(s)
Urinary Bladder , Urinary Catheterization , Female , Humans , Postpartum Period , Pregnancy , Prospective Studies , Ultrasonography , Urinary Bladder/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL
...