Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Phys Chem Lett ; 10(17): 5284-5291, 2019 Sep 05.
Article in English | MEDLINE | ID: mdl-31419136

ABSTRACT

The biological generation of oxygen by the oxygen-evolving complex (OEC) in photosystem II (PS II) is one of nature's most important reactions. The OEC is a Mn4Ca cluster that has multiple Mn-O-Mn and Mn-O-Ca bridges and binds four water molecules. Previously, binding of an additional oxygen was detected in the S2 to S3 transition. Here we demonstrate that early binding of the substrate oxygen to the five-coordinate Mn1 center in the S2 state is likely responsible for the S2 high-spin EPR signal. Substrate binding in the Mn1-OH form explains the prevalence of the high-spin S2 state at higher pH and its low-temperature conversion into the S3 state. The given interpretation was confirmed by X-ray absorption spectroscopic measurements, DFT, and broken symmetry DFT calculations of structures and magnetic properties. Structural, electronic, and spectroscopic properties of the high-spin S2 state model are provided and compared with the available S3 state models. New interpretation of the high-spin S2 state opens opportunity for analysis of factors controlling the oxygen substrate binding in PS II.


Subject(s)
Oxygen/metabolism , Photosystem II Protein Complex/metabolism , Density Functional Theory , Electron Spin Resonance Spectroscopy , Hydrogen-Ion Concentration , Magnetics , Manganese/chemistry , Oxygen/chemistry , Photosystem II Protein Complex/chemistry , Protein Binding , X-Ray Absorption Spectroscopy
2.
Xray Spectrom ; 48(5): 336-344, 2019.
Article in English | MEDLINE | ID: mdl-32606482

ABSTRACT

The application of X-ray emission spectroscopy (XES) has grown substantially with the development of X-ray free electron lasers, third and fourth generation synchrotron sources and high-power benchtop sources. By providing the high X-ray flux required for XES, these sources broaden the availability and application of this method of probing electronic structure. As the number of sources increase, so does the demand for X-ray emission detection and sample delivery systems that are cost effective and customizable. Here, we present a detailed fabrication protocol for von Hamos X-ray optics and give details for a 3D-printed spectrometer design. Additionally, we outline an automated, externally triggered liquid sample delivery system that can be used to repeatedly deliver nanoliter droplets onto a plastic substrate for measurement. These systems are both low cost, efficient and easy to recreate or modify depending on the application. A low cost multiple X-ray analyzer system enables measurement of dilute samples, whereas the sample delivery limits sample loss and replaces spent sample with fresh sample in the same position. While both systems can be used in a wide range of applications, the design addresses several challenges associated specifically with time-resolved XES (TRXES). As an example application, we show results from TRXES measurements of photosystem II, a dilute, photoactive protein.

3.
J Phys Chem Lett ; 10(3): 441-446, 2019 Feb 07.
Article in English | MEDLINE | ID: mdl-30566358

ABSTRACT

X-ray free electron lasers (XFELs) provide ultrashort intense X-ray pulses suitable to probe electron dynamics but can also induce a multitude of nonlinear excitation processes. These affect spectroscopic measurements and interpretation, particularly for upcoming brighter XFELs. Here we identify and discuss the limits to observing classical spectroscopy, where only one photon is absorbed per atom for a Mn2+ in a light element (O, C, H) environment. X-ray emission spectroscopy (XES) with different incident photon energies, pulse intensities, and pulse durations is presented. A rate equation model based on sequential ionization and relaxation events is used to calculate populations of multiply ionized states during a single pulse and to explain the observed X-ray induced spectral lines shifts. This model provides easy estimation of spectral shifts, which is essential for experimental designs at XFELs and illustrates that shorter X-ray pulses will not overcome sequential ionization but can reduce electron cascade effects.

4.
J Phys Chem Lett ; 8(12): 2584-2589, 2017 Jun 15.
Article in English | MEDLINE | ID: mdl-28524662

ABSTRACT

Understanding the function of Mn ions in biological and chemical redox catalysis requires precise knowledge of their electronic structure. X-ray emission spectroscopy (XES) is an emerging technique with a growing application to biological and biomimetic systems. Here, we report an improved, cost-effective spectrometer used to analyze two biomimetic coordination compounds, [MnIV(OH)2(Me2EBC)]2+ and [MnIV(O)(OH)(Me2EBC)]+, the second of which contains a key MnIV═O structural fragment. Despite having the same formal oxidation state (MnIV) and tetradentate ligands, XES spectra from these two compounds demonstrate different electronic structures. Experimental measurements and DFT calculations yield different localized spin densities for the two complexes resulting from MnIV-OH conversion to MnIV═O. The relevance of the observed spectroscopic changes is discussed for applications in analyzing complex biological systems such as photosystem II. A model of the S3 intermediate state of photosystem II containing a MnIV═O fragment is compared to recent time-resolved X-ray diffraction data of the same state.

5.
BMC Cancer ; 11: 444, 2011 Oct 12.
Article in English | MEDLINE | ID: mdl-21992187

ABSTRACT

BACKGROUND: In addition to breast imaging, ultrasound offers the potential for characterizing and distinguishing between benign and malignant breast tissues due to their different microstructures and material properties. The aim of this study was to determine if high-frequency ultrasound (20-80 MHz) can provide pathology sensitive measurements for the ex vivo detection of cancer in margins during breast conservation surgery. METHODS: Ultrasonic tests were performed on resected margins and other tissues obtained from 17 patients, resulting in 34 specimens that were classified into 15 pathology categories. Pulse-echo and through-transmission measurements were acquired from a total of 57 sites on the specimens using two single-element 50-MHz transducers. Ultrasonic attenuation and sound speed were obtained from time-domain waveforms. The waveforms were further processed with fast Fourier transforms to provide ultrasonic spectra and cepstra. The ultrasonic measurements and pathology types were analyzed for correlations. The specimens were additionally re-classified into five pathology types to determine specificity and sensitivity values. RESULTS: The density of peaks in the ultrasonic spectra, a measure of spectral structure, showed significantly higher values for carcinomas and precancerous pathologies such as atypical ductal hyperplasia than for normal tissue. The slopes of the cepstra for non-malignant pathologies displayed significantly greater values that differentiated them from the normal and malignant tissues. The attenuation coefficients were sensitive to fat necrosis, fibroadenoma, and invasive lobular carcinoma. Specificities and sensitivities for differentiating pathologies from normal tissue were 100% and 86% for lobular carcinomas, 100% and 74% for ductal carcinomas, 80% and 82% for benign pathologies, and 80% and 100% for fat necrosis and adenomas. Specificities and sensitivities were also determined for differentiating each pathology type from the other four using a multivariate analysis. The results yielded specificities and sensitivities of 85% and 86% for lobular carcinomas, 85% and 74% for ductal carcinomas, 100% and 61% for benign pathologies, 84% and 100% for fat necrosis and adenomas, and 98% and 80% for normal tissue. CONCLUSIONS: Results from high-frequency ultrasonic measurements of human breast tissue specimens indicate that characteristics in the ultrasonic attenuation, spectra, and cepstra can be used to differentiate between normal, benign, and malignant breast pathologies.


Subject(s)
Breast Neoplasms/diagnostic imaging , Breast Neoplasms/surgery , Mastectomy, Segmental , Breast Neoplasms/pathology , Feasibility Studies , Female , Humans , Intraoperative Period , Sensitivity and Specificity , Spectrum Analysis , Ultrasonography
SELECTION OF CITATIONS
SEARCH DETAIL
...