Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Med Phys ; 51(2): 1383-1395, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38064645

ABSTRACT

BACKGROUND: In time-of-flight PET, image quality and accuracy can be enhanced by improving the annihilation photon pair coincidence time resolution, which is the variation in the arrival time difference between the two annihilation photons emitted from each positron decay in the patient. Recent studies suggest direct detection of ionization tracks and their resulting modulation of optical properties, instead of scintillation, can improve the CTR significantly, potentially down to less than 10 ps CTR. However, the arrival times of the 511 keV photons are not predictable, leading to challenges in the spatiotemporal localization characterization of the induced charge carriers in the detector crystal. PURPOSE: To establish an optimized experimental setup for measuring ionization induced modulation of optical properties, it is critical to develop a versatile simulation algorithm that can handle multiple detector material properties and time-resolved charge carrier dynamics. METHODS: We expanded our previous algorithm and simulated ionization tracks, cascade time and induced charge carrier density over time in different materials. For designing a proof-of-concept experiment, we simulated ultrafast electrons and free-electron x-ray photons for timing characterization along with alpha and beta particles for higher spatial localization. RESULTS: With 3 MeV ultrafast electrons, by reducing detector crystal thickness, we can effectively reduce the ionization cascade time to 0.79 ps and deposited energy to 198.5 keV, which is on the order of the desired 511 keV energy. Alpha source simulations produced a cascade time of 2.45 ps and charge carrier density of 6.39 × 1020 cm-3 . Compared to the previous results obtained from 511 keV photon-induced ionization track simulations, the cascade time displayed similar characteristics, while the charge density was found to be higher. These findings suggest that alpha sources have the potential to generate a stronger ionization-induced signal using the modulation of optical properties as the detection mechanism. CONCLUSIONS: This work provides a guideline to understand, design and optimize an experimental platform that is highly sensitive and temporally precise enough to detect single 511 keV photon interactions with a goal to advance CTR for ToF-PET.


Subject(s)
Photons , Positron-Emission Tomography , Humans , Computer Simulation , X-Rays , Radiography , Positron-Emission Tomography/methods , Scintillation Counting/methods
2.
Phys Med Biol ; 66(4): 045032, 2021 02 12.
Article in English | MEDLINE | ID: mdl-33412537

ABSTRACT

In this work, we continue our study of a new method for the detection of ionizing radiation with the potential for a dramatic improvement in coincidence time resolution (CTR) for time-of-flight positron emission tomography (ToF-PET) using the modulation of a material's optical properties instead of the scintillation mechanism. Our previous work has shown that for non-scintillation materials such as bismuth silicon oxide (BSO) and cadmium telluride (CdTe), their refractive index can be modulated by annihilation photon interactions. The ultrafast nature of this process however remains unexplored. The ionizing radiation-induced charge carriers alter the local band structure in these materials, thus changing the complex refractive index. This mechanism is routinely used at the linac coherent light source (LCLS) facility of the SLAC National Accelerator Laboratory to measure x-ray pulse arrival times with femtosecond scale resolution for photon energies between 0.5 and 10 keV. The method described here follows that example by using a frequency chirped visible continuum pulse to provide a monotonic wavelength-to-time mapping by which one can measure the time-dependent refractive index modulation. In addition, we describe an interference-based measurement setup that allows for significantly improved sensitivity while preserving a timing precision of approximately 10 fs (σ) when measuring the arrival time of below 10 keV x-ray pulses with yttrium aluminum garnet (YAG) crystal. The method is presented in the context of ToF-PET application with further discussions on the potential CTR achievable if a similar detection concept is adopted for detecting 511 keV photons. Semi-empirical analysis indicates that the predicted CTR achievable is on the order of 1 ps (FWHM).


Subject(s)
Optical Phenomena , Photons , Bismuth , Cadmium Compounds , Quantum Dots , Tellurium , Tomography, X-Ray Computed
3.
Phys Med Biol ; 65(21): 215021, 2020 11 03.
Article in English | MEDLINE | ID: mdl-32707569

ABSTRACT

The concept of using the modulation mechanisms of a material's optical properties for annihilation photon detection has been proposed as a potential method to significantly improve the coincidence time resolution (CTR) of positron emission tomography detectors. However, the possibility of detecting individual 511 keV photons with largely improved CTR using the proposed detection method has not yet been demonstrated, either experimentally or theoretically. In addition, the underlying physical picture of the optical modulation effects induced by annihilation photons has not been fully understood. In this work, we perform simulation studies including generation of the annihilation photon-induced ionization energy deposition trajectory, estimation of the charge carrier cascade time and temporal variance, simulation of the distribution of ionization-induced charge carrier density, and calculation of the strength of the modulation of two optical parameters: the absorption coefficient and the refractive index, as well as evaluation of the resulting optical intensity and phase change experienced by a probe laser beam. Our simulation results show that the average absorption coefficient modulation induced by individual 511 keV photon interactions is around 0.04 cm-1, and the average refractive index change is 3.6 × 10-5, leading to modulations in the probe laser intensity of around 0.1% and phase modulation of around 0.05 radians. We have also found that the ionization process induced by a single 511 keV photon interaction occurs within 2.3 ps with a temporal variance of 0.4 ps. The fundamental limit on CTR using the optical property modulation-based detection mechanism is estimated to be around 1.2 ps full width at half maximum. Our simulation results indicate that with proper experiment design, it is possible to detect the ionization produced by an individual 511 keV photon with significantly improved CTR using the optical property modulation-based detection concept.


Subject(s)
Computer Simulation , Optical Phenomena , Positron-Emission Tomography , Photons , Radiometry , Time Factors
4.
Opt Express ; 21(20): 23160-8, 2013 Oct 07.
Article in English | MEDLINE | ID: mdl-24104230

ABSTRACT

Surgical procedures as a prelude to optical imaging are a rate-limiting step in experimental neuroscience. Towards automation of these procedures, we describe the use of nonlinear optical techniques to create a thinned skull window for transcranial imaging. Metrology by second harmonic generation was used to map the surfaces of the skull and define a cutting path. Plasma-mediated laser ablation was utilized to cut bone. Mice prepared with these techniques were used to image subsurface cortical vasculature and blood flow. The viability of the brain tissue was confirmed via histological analysis and supports the utility of solely optical techniques for osteotomy and potentially other surgical procedures.


Subject(s)
Optical Imaging/methods , Osteotomy/methods , Skull/surgery , Animals , Immunoassay , Laser Therapy , Mice , Parietal Lobe/pathology , Photons , Plasma Gases
5.
Curr Opin Neurobiol ; 22(1): 24-33, 2012 Feb.
Article in English | MEDLINE | ID: mdl-22088392

ABSTRACT

The controlled cutting of tissue with laser light is a natural technology to combine with automated stereotaxic surgery. A central challenge is to cut hard tissue, such as bone, without inducing damage to juxtaposed soft tissue, such as nerve and dura. We review past work that demonstrates the feasibility of such control through the use of ultrafast laser light to both cut and generate optical feedback signals via second harmonic generation and laser induced plasma spectra.


Subject(s)
Laser Therapy/instrumentation , Laser Therapy/methods , Neurosurgical Procedures/instrumentation , Neurosurgical Procedures/methods , Surgery, Computer-Assisted/methods , Animals , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...