Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Comput Biol Med ; 175: 108494, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38688124

ABSTRACT

BACKGROUND & OBJECTIVE: Aortic dissection (AD) is a serious condition requiring rapid and accurate diagnosis. In this study, we aimed to improve the diagnostic accuracy of AD by presenting a novel method for aortic segmentation in computed tomography images that uses a combination of a transformer and a UNet cascade network with a Zoom-Out and Zoom-In scheme (ZOZI-seg). METHODS: The proposed method segments each compartment of the aorta, comprising the true lumen (TL), false lumen (FL), and thrombosis (TH) using a cascade strategy that captures both the global context (anatomical structure) and the local detail texture based on the dynamic patch size with ZOZI schemes. The ZOZI-seg model has a two-stage architecture using both a "3D transformer for panoptic context-awareness" and a "3D UNet for localized texture refinement." The unique ZOZI strategies for patching were demonstrated in an ablation study. The performance of our proposed ZOZI-seg model was tested using a dataset from Asan Medical Center and compared with those of existing models such as nnUNet and nnFormer. RESULTS: In terms of segmentation accuracy, our method yielded better results, with Dice similarity coefficients (DSCs) of 0.917, 0.882, and 0.630 for TL, FL, and TH, respectively. Furthermore, we indirectly compared our model with those in previous studies using an external dataset to evaluate its robustness and generalizability. CONCLUSIONS: This approach may help in the diagnosis and treatment of AD in different clinical situations and provide a strong basis for further research and clinical applications.


Subject(s)
Aortic Dissection , Tomography, X-Ray Computed , Humans , Aortic Dissection/diagnostic imaging , Tomography, X-Ray Computed/methods , Algorithms
2.
Korean Circ J ; 54(1): 30-39, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38111183

ABSTRACT

BACKGROUND AND OBJECTIVES: Intravascular ultrasound (IVUS) evaluation of coronary artery morphology is based on the lumen and vessel segmentation. This study aimed to develop an automatic segmentation algorithm and validate the performances for measuring quantitative IVUS parameters. METHODS: A total of 1,063 patients were randomly assigned, with a ratio of 4:1 to the training and test sets. The independent data set of 111 IVUS pullbacks was obtained to assess the vessel-level performance. The lumen and external elastic membrane (EEM) boundaries were labeled manually in every IVUS frame with a 0.2-mm interval. The Efficient-UNet was utilized for the automatic segmentation of IVUS images. RESULTS: At the frame-level, Efficient-UNet showed a high dice similarity coefficient (DSC, 0.93±0.05) and Jaccard index (JI, 0.87±0.08) for lumen segmentation, and demonstrated a high DSC (0.97±0.03) and JI (0.94±0.04) for EEM segmentation. At the vessel-level, there were close correlations between model-derived vs. experts-measured IVUS parameters; minimal lumen image area (r=0.92), EEM area (r=0.88), lumen volume (r=0.99) and plaque volume (r=0.95). The agreement between model-derived vs. expert-measured minimal lumen area was similarly excellent compared to the experts' agreement. The model-based lumen and EEM segmentation for a 20-mm lesion segment required 13.2 seconds, whereas manual segmentation with a 0.2-mm interval by an expert took 187.5 minutes on average. CONCLUSIONS: The deep learning models can accurately and quickly delineate vascular geometry. The artificial intelligence-based methodology may support clinicians' decision-making by real-time application in the catheterization laboratory.

SELECTION OF CITATIONS
SEARCH DETAIL
...