Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 30
Filter
1.
Curr Med Imaging ; 20: e240523217293, 2024.
Article in English | MEDLINE | ID: mdl-37226797

ABSTRACT

BACKGROUND: Deep learning (DL) can improve image quality by removing noise from accelerated MRI. OBJECTIVE: To compare the quality of various accelerated imaging applications in knee MRI with and without DL. METHOD: We analyzed 44 knee MRI scans from 38 adult patients using the DL-reconstructed parallel acquisition technique (PAT) between May 2021 and April 2022. The participants underwent sagittal fat-saturated T2-weighted turbo-spin-echo accelerated imaging without DL (PAT-2 [2-fold parallel accelerated imaging], PAT-3, and PAT-4) and with DL (DL with PAT-3 [PAT-3DL] and PAT-4 [PAT-4DL]). Two readers independently evaluated subjective image quality (diagnostic confidence of knee joint abnormalities, subjective noise and sharpness, and overall image quality) using a 4-point grading system (1-4, 4=best). Objective image quality was assessed based on noise (noise power) and sharpness (edge rise distance). RESULTS: The mean acquisition times for PAT-2, PAT-3, PAT-4, PAT-3DL, and PAT-4DL sequences were 2:55, 2:04, 1:33, 2:04, and 1:33 min, respectively. Regarding subjective image quality, PAT-3DL and PAT-4DL scored higher than PAT-2. Objectively, DL-reconstructed imaging had significantly lower noise than PAT-3 and PAT-4 (P <0.001), but the results were not significantly different from those for PAT-2 (P >0.988). Objective image sharpness did not differ significantly among the imaging combinations (P =0.470). The inter-reader reliability ranged from good to excellent (κ = 0.761­0.832). CONCLUSION: PAT-4DL imaging in knee MRI exhibits similar subjective image quality, objective noise, and sharpness levels compared with conventional PAT-2 imaging, with an acquisition time reduction of 47%.


Subject(s)
Deep Learning , Adult , Humans , Reproducibility of Results , Prospective Studies , Magnetic Resonance Imaging/methods
2.
J Knee Surg ; 36(9): 988-994, 2023 Jul.
Article in English | MEDLINE | ID: mdl-35820433

ABSTRACT

This article determines the accuracy and reliability of dual-energy computed tomography (DECT) with metal artifact reduction (MAR) in the evaluation of femoral component rotation after total knee arthroplasty (TKA), in comparison with conventional CT images. A total of 49 patients (mean age, 69 years; 42 women) who underwent TKA between January 2019 and March 2020 were retrospectively enrolled. Femoral component rotation, including the anatomic and surgical transepicondylar axes, was evaluated with preoperative conventional CT and postoperative conventional CT and DECT with MAR. Surgical femoral component rotation was also assessed as a reference standard. Accuracy was assessed using paired t-test, and inter- and intraobserver reliability using intraclass correlation coefficients (ICCs) based on postoperative conventional CT and DECT with MAR. Clinical outcomes were evaluated using the Knee Society objective and functional scores. Accuracy of femoral component rotation was not significantly different from that of surgical rotation with both conventional CT and DECT with MAR. However, inter- and intraobserver reliability were better for DECT with MAR (ICC: 0.953-0.966) than for conventional CT (ICC: 0.641-0.749). The Knee Society objective and functional scores improved 1 year postoperatively. CONCLUSION: DECT with MAR showed accurate and more reliable results than did conventional CT in the evaluation of femoral component rotation after TKA.


Subject(s)
Arthroplasty, Replacement, Knee , Osteoarthritis, Knee , Humans , Female , Aged , Arthroplasty, Replacement, Knee/methods , Retrospective Studies , Reproducibility of Results , Artifacts , Tomography, X-Ray Computed/methods , Femur/diagnostic imaging , Femur/surgery , Knee Joint/diagnostic imaging , Knee Joint/surgery , Osteoarthritis, Knee/surgery
3.
Sensors (Basel) ; 22(17)2022 Aug 24.
Article in English | MEDLINE | ID: mdl-36080847

ABSTRACT

Despite the lack of findings in laryngeal endoscopy, it is common for patients to undergo vocal problems after thyroid surgery. This study aimed to predict the recovery of the patient's voice after 3 months from preoperative and postoperative voice spectrograms. We retrospectively collected voice and the GRBAS score from 114 patients undergoing surgery with thyroid cancer. The data for each patient were taken from three points in time: preoperative, and 2 weeks and 3 months postoperative. Using the pretrained model to predict GRBAS as the backbone, the preoperative and 2-weeks-postoperative voice spectrogram were trained for the EfficientNet architecture deep-learning model with long short-term memory (LSTM) to predict the voice at 3 months postoperation. The correlation analysis of the predicted results for the grade, breathiness, and asthenia scores were 0.741, 0.766, and 0.433, respectively. Based on the scaled prediction results, the area under the receiver operating characteristic curve for the binarized grade, breathiness, and asthenia were 0.894, 0.918, and 0.735, respectively. In the follow-up test results for 12 patients after 6 months, the average of the AUC values for the five scores was 0.822. This study showed the feasibility of predicting vocal recovery after 3 months using the spectrogram. We expect this model could be used to relieve patients' psychological anxiety and encourage them to actively participate in speech rehabilitation.


Subject(s)
Voice Disorders , Asthenia , Humans , Neural Networks, Computer , Retrospective Studies , Thyroid Gland , Treatment Outcome , Voice Quality
4.
Invest Radiol ; 57(12): 826-833, 2022 12 01.
Article in English | MEDLINE | ID: mdl-35776434

ABSTRACT

OBJECTIVES: This study aimed to examine various combinations of parallel imaging (PI) and simultaneous multislice (SMS) acceleration imaging using deep learning (DL)-enhanced and conventional reconstruction. The study also aimed at comparing the diagnostic performance of the various combinations in internal knee derangement and provided a quantitative evaluation of image sharpness and noise using edge rise distance (ERD) and noise power (NP), respectively. MATERIALS AND METHODS: The data from adult patients who underwent knee magnetic resonance imaging using various DL-enhanced acquisitions between June 2021 and January 2022 were retrospectively analyzed. The participants underwent conventional 2-fold PI and DL protocols with 4- to 8-fold acceleration imaging (P2S2 [2-fold PI with 2-fold SMS], P3S2, and P4S2). Three readers evaluated the internal knee derangement and the overall image quality. The diagnostic performance was calculated using consensus reading as a standard reference, and we conducted comparative evaluations. We calculated the ERD and NP for quantitative evaluations of image sharpness and noise, respectively. Interreader and intermethod agreements were calculated using Fleiss κ. RESULTS: A total of 33 patients (mean age, 49 ± 19 years; 20 women) were included in this study. The diagnostic performance for internal knee derangement and the overall image quality were similar among the evaluated protocols. The NP values were significantly lower using the DL protocols than with conventional imaging ( P < 0.001), whereas the ERD values were similar among these methods ( P > 0.12). Interreader and intermethod agreements were moderate-to-excellent (κ = 0.574-0.838) and good-to-excellent (κ = 0.755-1.000), respectively. In addition, the mean acquisition time was reduced by 47% when using DL with P2S2, by 62% with P3S2, and by 71% with P4S2, compared with conventional P2 imaging (2 minutes and 55 seconds). CONCLUSIONS: The combined use of DL-enhanced 8-fold acceleration imaging (4-fold PI with 2-fold SMS) showed comparable performance with conventional 2-fold PI for the evaluation of internal knee derangement, with a 71% reduction in acquisition time.


Subject(s)
Deep Learning , Joint Diseases , Adult , Humans , Female , Middle Aged , Aged , Retrospective Studies , Reproducibility of Results , Magnetic Resonance Imaging/methods , Acceleration
5.
Eur Radiol ; 32(3): 1419-1428, 2022 Mar.
Article in English | MEDLINE | ID: mdl-34642809

ABSTRACT

OBJECTIVES: To investigate the clinical and radiologic predictors of postoperative recurrent septic arthritis of the shoulder (SAS) using multivariable analysis. METHODS: Forty-three patients (mean age, 65 years; 24 women) who underwent surgery for SAS between January 2011 and October 2019 were retrospectively enrolled. An orthopedic surgeon assessed clinical (age, sex, comorbidity, duration from symptom onset to MR imaging and surgery, surgical method, antibiotic usage), laboratory (serum white blood cell [WBC] count, C-reactive protein [CRP] level, synovial cell count), and surgical findings (culture/biopsy results). Two musculoskeletal radiologists evaluated MR imaging findings (bone marrow [reactive bone marrow edema, osteomyelitis, osteochondral erosion] and soft tissue [synovitis, bursitis, muscle edema, abscess] abnormalities). Recurrent SAS was evaluated at ≥ 12 months postoperatively. Univariable and multivariable analyses were performed to determine the best predictor of recurrent SAS. RESULTS: The overall recurrent SAS rate was 33% (14/43). On univariable analysis, mean age (without recurrence vs. recurrence: 68 vs. 59 years, p = .04), mean duration from symptom onset to surgery (18 vs. 25 days, p = .02), serum WBC count (12,000 vs. 9,000 cells/mL3, p = .04), CRP level (13 vs. 6 mg/L, p = .01), and osteomyelitis on MR imaging (p < .01 for both readers) significantly differed between patients with and without recurrence; on multivariable analysis, only osteomyelitis on MR imaging was significantly associated with recurrent SAS for both readers (p = .02 and .01 for each reader respectively). The inter-reader agreement was good (κ = .62-1.0) for all MR imaging findings, except for muscle edema (fair, κ = .37). CONCLUSION: Osteomyelitis on MR imaging was the best predictor of recurrent SAS. KEY POINTS: • Osteomyelitis on preoperative MR imaging was the best predictor associated with recurrent septic arthritis of the shoulder on multivariable analysis including clinical, laboratory, and MR findings. • In multivariable analyses focused on each bone marrow abnormality, with adjustment for clinical and laboratory parameters, the presence of reactive bone marrow edema and osteochondral erosion on MR imaging showed no significant association with recurrent septic arthritis of the shoulder.


Subject(s)
Arthritis, Infectious , Osteomyelitis , Aged , Arthritis, Infectious/diagnostic imaging , Female , Humans , Magnetic Resonance Imaging , Osteomyelitis/diagnostic imaging , Retrospective Studies , Shoulder
6.
Clin Imaging ; 82: 216-223, 2022 Feb.
Article in English | MEDLINE | ID: mdl-34896934

ABSTRACT

PURPOSE: To find the best simultaneous multislice (SMS) accelerated setting for clinical application in knee MRI. MATERIAL AND METHODS: Thirty-three patients (mean age, 54 years; 21 women) who underwent knee MRI (conventional/SMS sequences) between June and October 2020 were enrolled. Two radiologists retrospectively evaluated sagittal T1- and T2-weighted conventional (2-fold parallel acquisition technique [PAT-2]) and SMS (SMS-2 [PAT-2 with 2-fold SMS], SMS-3, and SMS-4) images. For qualitative analysis, artifacts (zebra/residual aliasing) and diagnostic confidence for internal derangement of knee (bone marrow, cartilage, meniscus, anterior cruciate ligament, and synovium abnormalities) were evaluated. For quantitative analysis, contrast-to-noise ratios of bone marrow, meniscus, joint effusion, and ligament were evaluated. RESULTS: Compared to PAT-2 (2 min 32 s), mean acquisition time was reduced by 47% in SMS-2; 64%, SMS-3; and 70%, SMS-4. In qualitative analysis, zebra artifacts were only seen on T2-weighted SMS images. The more SMS was applied, the more zebra and residual aliasing artifacts were seen and the lower diagnostic confidence was for internal derangement. However, qualitative analysis showed acceptable image quality in SMS-2 and SMS-3 images, but not in SMS-4 images. In quantitative analysis, SMS-4 images showed the lowest contrast-to-noise ratios and there were no significant differences among PAT-2, SMS-2, and SMS-3 images. CONCLUSION: Applying SMS-3 to knee MRI reduced scan time and showed acceptable image quality compared to conventional (PAT-2). However, when evaluating SMS images, radiologists should know that when more SMS is applied, more zebra and residual aliasing artifacts appear.


Subject(s)
Acceleration , Magnetic Resonance Imaging , Feasibility Studies , Humans , Reproducibility of Results , Retrospective Studies
7.
Medicine (Baltimore) ; 100(18): e25800, 2021 May 07.
Article in English | MEDLINE | ID: mdl-33950980

ABSTRACT

ABSTRACT: We aimed to determine the incremental value of magnetic resonance generated synthetic computed tomography (MRCT), evaluate cervical ossification of the posterior longitudinal ligament (OPLL), and compare the computed tomography (CT) numbers between MRCT and conventional CT.Twenty-two patients who underwent magnetic resonance imaging (MRI) with MRCT protocols and CT were enrolled. MRCT images were generated from 3D-T2-weighted imaging, 3D-pointwise-encoding time reduction with radial acquisition, 3D-T1-Dixon, and 3D-time-of-flight sequences. Two radiologists independently evaluated the presence of OPLL at each cervical spine level during sessions 1 (MRI alone) and 2 (MRI + MRCT). CT was the reference standard for the presence of OPLL. One reader measured the mean CT number of the vertebral body and spinous process at each cervical spine level in the MRCT and CT images.Sensitivity for the detection of OPLL was markedly higher in session 2 (MRI + MRCT) than in session 1 (MRI alone), as measured by both readers (47% vs. 90%, reader 1; 63% vs. 93%, reader 2). The mean CT number of MRCT and CT showed a moderate to strong positive correlation (ρ = .42-.72, P < .001).The combined use of MRCT and MRI showed improved sensitivity for the evaluation of cervical OPLL. The mean CT number of MRCT and CT showed a positive correlation.


Subject(s)
Cervical Vertebrae/diagnostic imaging , Image Processing, Computer-Assisted , Magnetic Resonance Imaging/methods , Ossification of Posterior Longitudinal Ligament/diagnosis , Tomography, X-Ray Computed/methods , Adult , Aged , Cervical Vertebrae/pathology , Feasibility Studies , Female , Humans , Male , Middle Aged , Multimodal Imaging/methods , Ossification of Posterior Longitudinal Ligament/pathology , Retrospective Studies , Sensitivity and Specificity
8.
Taehan Yongsang Uihakhoe Chi ; 82(4): 862-875, 2021 Jul.
Article in English | MEDLINE | ID: mdl-36238060

ABSTRACT

Purpose: To investigate the MRI features associated with neural foraminal stenosis (NFS) in patients older than 60 years with lumbar (L) radiculopathy. Materials and Methods: This study included 133 retrospectively selected patients older than 60 years with lumbar radiculopathy who had undergone a lumbar spine MRI (from January 2018 to April 2018). For L4/L5 and L5/sacral (S)1 levels, NFS was reviewed blindly by two radiologists. Spondylolisthesis, retrolisthesis, disc height loss, disc bulging/herniation/central canal stenosis, ligamentum flavum thickening, and facet hypertrophy were evaluated separately for the NFS and non-NFS groups, and they were compared using univariate and multivariate analyses. Results: The univariate analysis revealed that disc height loss (p = 0.006) was associated with NFS for L4/L5. For L5/S1, both spondylolisthesis (p = 0.005) and facet hypertrophy (p = 0.006) were associated with NFS. The multivariate logistic analysis revealed that disc height loss was associated with NFS for L4/L5 [odds ratio (OR) = 4.272; 95% confidence interval (CI) 1.736-10.514]. For L5/S1, spondylolisthesis (OR = 3.696; 95% CI 1.297-10.530) and facet hypertrophy (OR = 6.468; 95% CI 1.283-32.617) were associated with NFS. Conclusion: Disc height loss was associated with NFS for L4/L5 and spondylJophy were associated with NFS for L5/S1.

9.
Taehan Yongsang Uihakhoe Chi ; 82(5): 1258-1273, 2021 Sep.
Article in English | MEDLINE | ID: mdl-36238392

ABSTRACT

Purpose: The balloon-stent technique (BST) has certain strengths as an assisted technique for the treatment of complex aneurysms. After Atlas release, the BST can be executed without an exchange maneuver of the balloon to the stent-delivery catheter. The purpose of this article is to share our experience with the BST using the Scepter-Atlas combination. Materials and Methods: Device inspection led us to a simple method to avoid failure in loading Atlas to the Scepter. From March 2018 to December 2019, 57 unruptured distal internal carotid artery (dICA) aneurysms were treated with coil embolization; among which, 25 aneurysms in 23 patients were treated with BST. Clinical and angiographic data were retrospectively collected and reviewed. Results: The technical success rate of the Scepter-Atlas combination increased from 50% to 100% after careful inspection. BST angiographic results were comparable to the stent-assisted coil (SAC) group treated during the immediately post-embolization same period (modified Raymond-Roy classification [MRRC] 1 & 2 84% in BST, 96.3% in SAC) and during short-term follow-up (MRRC 1 & 2 95.8% in BST, 88.4% in SAC). A small number of patients showed periprocedural complications, but none had clinical consequences. Conclusion: BST using the Scepter-Atlas combination can provide an effective and safe method for the treatment of dICA aneurysms. Scepters can be used as delivery catheters for Atlas.

11.
Eur Radiol ; 31(5): 3156-3164, 2021 May.
Article in English | MEDLINE | ID: mdl-33057781

ABSTRACT

OBJECTIVES: To compare image noise and sharpness of vessels, liver, and muscle in lower extremity CT angiography between "adaptive statistical iterative reconstruction-V" (ASIR-V) and deep learning reconstruction "TrueFidelity" (TFI). METHODS: Thirty-seven patients (mean age, 65.2 years; 32 men) with lower extremity CT angiography were enrolled between November and December 2019. Images were reconstructed with two ASIR-V (blending factor of 80% and 100% (AV-100)) and three TFI (low-, medium-, and high-strength-level (TF-H) settings). Two radiologists evaluated these images for vessels (aorta, femoral artery, and popliteal artery), liver, and psoas muscle. For quantitative analyses, conventional indicators (CT number, image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR)) and blur metric values (indicating the degree of image sharpness) of selected regions of interest were determined. For qualitative analyses, the degrees of quantum mottle and blurring were assessed. RESULTS: The higher the blending factor in ASIR-V or the strength in TFI, the lower the noise, the higher the SNR and CNR values, and the higher the blur metric values in all structures. The SNR and CNR values of TF-H images were significantly higher than those of AV-80 images and similar to those of AV-100 images. The blur metric values in TFI images were significantly lower than those in ASIR-V images (p < 0.001), indicating increased sharpness. Among all the investigated image procedures, the overall qualitative image quality was best in TF-H images. CONCLUSION: TF-H was the most balanced image in terms of image noise and sharpness among the examined image combinations. KEY POINTS: • Deep learning image reconstruction "TrueFidelity" is superior to iterative reconstruction "ASIR-V" regarding image noise and sharpness. • The high-strength "TrueFidelity" approach generated the best image quality among the examined image reconstruction procedures. • In iterative and deep learning CT image reconstruction, the higher the blending and strength factors, the lower the image noise and the poorer the image sharpness.


Subject(s)
Deep Learning , Aged , Algorithms , Humans , Male , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted , Signal-To-Noise Ratio , Tomography, X-Ray Computed
12.
Eur J Radiol ; 132: 109254, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32956998

ABSTRACT

PURPOSE: To evaluate the effects of gemstone spectral imaging-metal artifact reduction (GSI-MAR) on different dual-energy CT monochromatic images for patients with total knee replacement arthroplasty (TKRA) and to identify an appropriate protocol for clinical practice. METHOD: We enrolled 34 patients with TKRA. CT images were iteratively reconstructed with or without GSI-MAR at different energy levels (70, 95, 115, and 140 keV). Two radiologists evaluated the objective and subjective image qualities and MAR-related new artifacts at the femoral and tibial levels. For objective analysis, the mean CT number and image noise of the selected regions of interest in the bone and muscle were recorded. To quantitatively evaluate the performance of GSI-MAR, a structural similarity index (SSIM) was used. For subjective analysis, streak artifacts and diagnostic confidence in detecting periprosthetic complications were assessed. Objective and subjective indicators were compared among the image combinations. RESULTS: In the femoral component, 140 keV monochromatic energy images with GSI-MAR showed the lowest mean CT number, image noise, SSIM value, and streak artifacts, and the best diagnostic confidence. In the tibial component, the image noise differed significantly, but the SSIM and subjective indicators were similar among the image combinations. MAR-related new artifacts were noted in 14.7% of images, and all of them were observed in only the femoral component. CONCLUSION: GSI-MAR with higher-energy monochromatic images showed fewer metal artifacts and better visualization. We recommend 140 keV with GSI-MAR for improving image quality and 140 keV without GSI-MAR for identifying MAR-related new artifacts when evaluating TKRA.


Subject(s)
Arthroplasty, Replacement, Knee , Artifacts , Algorithms , Humans , Metals , Radiographic Image Interpretation, Computer-Assisted , Tomography, X-Ray Computed
13.
J Hand Surg Eur Vol ; 45(3): 242-249, 2020 Mar.
Article in English | MEDLINE | ID: mdl-31426710

ABSTRACT

Osborne's modified decompression involves repairing Osborne's ligament beneath the ulnar nerve after simple decompression for idiopathic cubital tunnel syndrome. In this retrospective interrupted time series, 31 patients underwent modified simple decompression and 20 patients underwent conventional simple decompression. In the modified simple decompression group, the ulnar nerve length was measured at operation in full elbow flexion and extension before and after repair of Osborne's ligament. Ulnar nerve instability during elbow motion was measured using ultrasonography before operation and at 12 months after operation. In patients treated by modified simple decompression, the ulnar nerve length in full elbow flexion reduced significantly after repair of Osborne's ligament. At 12 months after surgery, the grade of ulnar nerve instability was lower in the modified simple decompression group than in the conventional simple decompression group. The clinical outcomes did not differ significantly between the groups at 24 months after operation. Level of evidence: III.


Subject(s)
Cubital Tunnel Syndrome , Cubital Tunnel Syndrome/surgery , Decompression, Surgical , Humans , Ligaments/surgery , Retrospective Studies , Ulnar Nerve/diagnostic imaging , Ulnar Nerve/surgery
14.
Eur Radiol ; 30(4): 2191-2198, 2020 Apr.
Article in English | MEDLINE | ID: mdl-31822976

ABSTRACT

OBJECTIVES: To evaluate the diagnostic performance of dual-energy CT with water-hydroxyapatite (HAP) imaging for bone marrow edema in patients with non-traumatic hip pain. METHODS: Forty patients (mean age, 58 years; 16 male and 24 female) who underwent rapid kVp-switching dual-energy CT and MRI within 1 month between April 2018 and February 2019 with hip pain but no trauma were enrolled. Two radiologists retrospectively evaluated 80 hip joints for the presence, extent (femoral head involved, head and neck, and head to intertrochanter), and severity (mild edema, moderate, severe) of bone marrow edema on dual-energy water-HAP images. Water mass density (mg/cm3) on water-HAP images was determined with region of interest-based quantitative analysis. MRI served as the standard of reference. RESULTS: Sensitivity, specificity, and accuracy of readers 1 and 2 for the identification of bone marrow edema in water-HAP images were 85% and 85%, 93% and 73%, and 89% and 79%, respectively. The area under the receiver operating characteristic curve was 0.96 for reader 1 and 0.91 for reader 2 for differentiation of the presence of edema from no edema. The optimal water mass density to classify the presence of edema for reader 1 was 951 mg/cm3 with 93% sensitivity and 93% specificity and for reader 2 was 957 mg/cm3 with 80% sensitivity and 80% specificity. The more severe the edema, the higher was the mean water density value (p < 0.035). CONCLUSION: Dual-energy water-HAP images showed good diagnostic performance for bone marrow edema in patients with non-traumatic hip pain. KEY POINTS: • Dual-energy water-HAP imaging depicts bone marrow edema in patients with non-traumatic hip pain and may serve as an alternative to MRI in select patients. • A cutoff value of 951 mg/cm3mean water mass density results in 93% sensitivity and 93% specificity for the detection of bone marrow edema. • The more severe the bone marrow edema, the higher the mean water density value.


Subject(s)
Bone Marrow Diseases/diagnostic imaging , Edema/diagnostic imaging , Femur Head/diagnostic imaging , Tomography, X-Ray Computed/methods , Adult , Aged , Arthralgia , Bone Marrow/diagnostic imaging , Data Collection , Durapatite , Female , Femur/diagnostic imaging , Hip Joint/diagnostic imaging , Humans , Magnetic Resonance Imaging/methods , Male , Middle Aged , ROC Curve , Retrospective Studies , Sensitivity and Specificity , Water
15.
Medicina (Kaunas) ; 56(1)2019 Dec 19.
Article in English | MEDLINE | ID: mdl-31861714

ABSTRACT

Background and Objectives: Lumbar traction is widely used as a non-operative treatment for lumbar intervertebral disc disease. The effect of traditional traction (TT) using linear-type traction devices remains controversial for various reasons, including technical limitations. Thus, the purpose of this study was to compare the effects of the newly developed lumbar lordotic curve-controlled traction (L-LCCT) and TT on functional changes in patients and morphological changes in the vertebral disc. Materials and Methods: A total of 40 patients with lumbar intervertebral disc disease at the L4/5 or L5/S1 level as confirmed by magnetic resonance imaging were recruited and divided into two groups (L-LCCT or TT). The comprehensive health status changes of the patients were recorded using pain and functional scores (the visual analogue scale, the Oswestry Disability Index, and the Roland-Morris Disability Questionnaire) and morphological changes (in the lumbar central canal area) before and after traction treatment. Results: Pain scores were significantly decreased after traction in both groups (p < 0.05). However, functional scores and morphological changes improved significantly after treatment in the L-LCCT group only (p < 0.05). Conclusions: We suggest that L-LCCT is a viable option for resolving the technical limitations of TT by maintaining the lumbar lordotic curve in patients with lumbar intervertebral disc disease.


Subject(s)
Intervertebral Disc Displacement/therapy , Recovery of Function , Traction/standards , Adult , Double-Blind Method , Female , Humans , Intervertebral Disc Displacement/complications , Lumbosacral Region/abnormalities , Magnetic Resonance Imaging/methods , Male , Middle Aged , Pain/etiology , Pain Management/methods , Pain Management/standards , Traction/methods , Traction/statistics & numerical data
17.
Article in English | MEDLINE | ID: mdl-31248064

ABSTRACT

The newly developed cervical lordotic curve-controlled traction (C-LCCT) appears to be an ideal method to improve the treatment outcome in patients with cervical intervertebral disc disease. The purpose of this study was to investigate the treatment outcomes of C-LCCT including the functional and morphological changes of the cervical intervertebral disc compared to traditional traction (TT) with a randomized controlled trial design. A total of 40 patients with cervical intervertebral disc disease at the C5/6 level confirmed by magnetic resonance imaging were recruited and assigned to either the C-LCCT group or the TT group. The comprehensive health status changes of the patients were recorded using pain and functional scores (Visual Analogue Scale, Oswestry Disability Index) and morphological changes (cervical lordosis, cervical central canal area) before and after the traction treatment. Both groups showed a significant improvement in pain scores after traction (p < 0.05). The functional score and morphological changes improved significantly after treatment in the C-LCCT group. However, there was no significant improvement in the TT group (p < 0.05). The C-LCCT showed significant pain, functional, and morphological improvement compared to TT. C-LCCT could be effective in improving the treatment outcomes of the traction technique in patients with cervical intervertebral disc disease.


Subject(s)
Intervertebral Disc Degeneration/therapy , Intervertebral Disc Displacement/therapy , Intervertebral Disc/physiopathology , Lordosis/therapy , Traction/methods , Adult , Double-Blind Method , Female , Humans , Male , Middle Aged , Treatment Outcome
18.
BMC Musculoskelet Disord ; 19(1): 136, 2018 May 07.
Article in English | MEDLINE | ID: mdl-29734945

ABSTRACT

BACKGROUND: In lateral epicondylitis, even in the absence of apparent instability, subtle instability can be found under anesthesia. We wanted to ascertain the following: (1) how many elbows surgically treated with lateral epicondylitis showed subtle instability during examination under anesthesia (EUA), (2) how effective magnetic resonance imaging (MRI) was in predicting subtle instability, and (3) if any difference existed in preoperative clinical data between elbows with and without subtle instability during EUA. METHODS: One hundred and twenty-two elbows (117 patients) diagnosed with intractable lateral epicondylitis underwent surgical treatment. No elbow showed apparent instability with conventional physical examination. Under general anesthesia, the elbows were examined for subtle instability via fluoroscopy and divided into unstable and stable groups. Potential prognostic factors and functional scores were assessed retrospectively. The MRIs were reviewed again by two radiologists. RESULTS: Seventeen elbows (unstable group, 13.9%) had subtle instability in EUA, while 105 elbows (stable group, 86.1%) did not. Lateral collateral ligament (LCL) complex injury was noted in the MRIs of 28 elbows. Fifteen elbows showed subtle instability among 28 elbows with abnormal MRI (positive predictive value, 53.6%), while 81 elbows did not show subtle instability among 82 elbows with normal MRI (negative predictive value, 98.7%). The preoperative visual analog scale score was higher in the unstable group than in the stable group (p < 0.001), and a history of multiple corticosteroid injections (≥3) was related to subtle instability in EUA (p = 0.042). Other factors showed no significant differences between both groups. CONCLUSIONS: Subtle instability resulting from LCL complex injury was noted in elbows with lateral epicondylitis. This could be visualized with fluoroscopic EUA, and preoperative MRI could be used to exclude subtle instability. Surgeons should consider checking for subtle instability, especially when patients have a history of multiple corticosteroid injections (≥3) or severe pain and MRI indicates instability.


Subject(s)
Elbow Joint/diagnostic imaging , Elbow Joint/surgery , Joint Instability/diagnostic imaging , Joint Instability/surgery , Tennis Elbow/diagnostic imaging , Tennis Elbow/surgery , Adult , Aged , Female , Humans , Magnetic Resonance Imaging/methods , Middle Aged , Preoperative Care/methods
19.
Korean J Intern Med ; 33(5): 883-892, 2018 09.
Article in English | MEDLINE | ID: mdl-28899084

ABSTRACT

BACKGROUND/AIMS: Endoscopic ultrasound-guided fine needle aspiration (EUSFNA) and brushing cytology are used worldwide to diagnose pancreatic and biliary malignant tumors. Liquid-based cytology (LBC) has been developed and it is currently used to overcome the limitations of conventional smears (CS). In this study, the authors aimed to compare the diagnostic value of the CellPrepPlus (CP; Biodyne) LBC method with CS in samples obtained using EUS-FNA and brushing cytology. METHODS: This study prospectively enrolled 75 patients with pancreatic or biliary lesions from June 2012 to October 2013. For cytological analyses, including inadequate specimens, benign and atypical were further classified into benign, and suspicious and malignant were subcategorized as malignant. Sensitivity, specificity, accuracy, and positive predictive values (PPV) and negative predictive values (NPV) were evaluated. RESULTS: In the EUS-FNA based cytological analysis of pancreatic specimens, CP had a sensitivity of 60.7%; specificity, 100%; accuracy, 77.1%; PPV, 100%; and NPV, 64.5%. CS had a sensitivity of 85.7%; specificity, 100%; accuracy, 91.7%; PPV, 100%; and NPV, 83.3%. In the brushing cytology based analysis of biliary specimens, CP had sensitivity of 53.1%; specificity, 100%; accuracy, 54.5%; PPV, 100%; and NPV, 6.3%. CS had a sensitivity of 78.1%; specificity, 100%; accuracy, 78.8%; PPV, 100%; and NPV, 12.5%. CONCLUSION: Our study found that CP had a lower sensitivity because of low cellularity compared with CS. Therefore, CP (LBC) has a lower diagnostic accuracy for pancreatic EUS-FNA based and biliary brush cytology based analyses compared with CS.


Subject(s)
Biliary Tract Neoplasms , Endoscopic Ultrasound-Guided Fine Needle Aspiration , Pancreatic Neoplasms , Aged , Biliary Tract Neoplasms/diagnosis , Biopsy, Fine-Needle , Endoscopy , Female , Humans , Male , Middle Aged , Pancreatic Neoplasms/diagnosis , Sensitivity and Specificity
20.
Yeungnam Univ J Med ; 35(1): 130-134, 2018 06.
Article in English | MEDLINE | ID: mdl-31620584

ABSTRACT

Heterotopic ossification (HO) around the hip joint is not uncommon following neurological injury. Often, surgical treatment is performed in patients with restricted motion and/or refractory pain due to grade III or IV HO according to Brooker classification. The major complication that occurs as a result of surgical HO removal is perioperative bleeding due to hyper-vascularization of the lesion. Here, we report a case of preoperative embolization in a 51-year-old male patient presenting with restricted bilateral hip range of motion (ROM) due to HO following a spinal cord injury. In the right hip without preoperative arterial embolization, massive bleeding occurred during surgical removal of HO. Thus, the patient received a transfusion postoperatively due to decreased serum hemoglobin levels. For surgery of the left hip, preoperative embolization of the arteries supplying HO was performed. Surgical treatment was completed without bleeding complications, and the patient recovered without a postoperative transfusion. This case highlights that, while completing surgical removal for ROM improvements, orthopedic surgeons should consider preoperative arterial embolization in patients with hip HO.

SELECTION OF CITATIONS
SEARCH DETAIL
...