1.
Med Phys ; 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38828894

ABSTRACT

BACKGROUND: Previous study proposed a method to measure linear energy transfer (LET) at specific points using the quenching magnitude of thin film solar cells. This study was conducted to propose a more advanced method for measuring the LET distribution. PURPOSE: This study focuses on evaluating the feasibility of estimating the proton LET distribution in proton therapy. The feasibility of measuring the proton LET and dose distribution simultaneously using a single-channel configuration comprising two solar cells with distinct quenching constants is investigated with the objective of paving the way for enhanced proton therapy dosimetry. METHODS: Two solar cells with different quenching constants were used to estimate the proton LET distribution. Detector characteristics (e.g., dose linearity and dose-rate dependency) of the solar cells were evaluated to assess their suitability for dosimetry applications. First, using a reference beam condition, the quenching constants of the two solar cells were determined according to the modified Birks equation. The signal ratios of the two solar cells were then evaluated according to proton LET in relation to the estimated quenching constants. The proton LET distributions of six test beams were obtained by measuring the signal ratios of the two solar cells at each depth, and the ratios were evaluated by comparing them with those calculated by Monte Carlo simulation. RESULTS: The detector characterization of the two solar cells including dose linearity and dose-rate dependence affirmed their suitability for use in dosimetry applications. The maximum difference between the LET measured using the two solar cells and that calculated by Monte Carlo simulation was 2.34 keV/µm. In the case of the dose distribution measured using the method proposed in this study, the maximum difference between range measured using the proposed method and that measured using a multilayered ionization chamber was 0.7 mm. The expected accuracy of simultaneous LET and dose distribution measurement using the method proposed in this study were estimated to be 3.82%. The signal ratios of the two solar cells, which are related to quenching constants, demonstrated the feasibility of measuring LET and dose distribution simultaneously. CONCLUSION: The feasibility of measuring proton LET and dose distribution simultaneously using two solar cells with different quenching constants was demonstrated. Although the method proposed in this study was evaluated using a single channel by varying the measuring depth, the results suggest that the proton LET and dose distribution can be simultaneously measured if the detector is configured in a multichannel form. We believe that the results presented in this study provide the envisioned transition to a multichannel configuration, with the promise of substantially advancing proton therapy's accuracy and efficacy in cancer treatment.

2.
Front Physiol ; 15: 1302301, 2024.
Article in English | MEDLINE | ID: mdl-38590693

ABSTRACT

Introduction: The aim of this study was to demonstrate the potential of an in vivo four-dimensional (4D) tracking system to accurately localize the radiation source, Iridium-192 (Ir-192) in high-dose rate brachytherapy. Methods: To achieve time-dependent 3D positioning of the Ir-192 source, we devised a 4D tracking system employing multiple compact detectors. During the system's design phase, we conducted comprehensive optimization and analytical evaluations of the diverging collimator employed for detection purposes. Subsequently, we executed 3D reconstruction and positioning procedures based on the 2D images obtained by six detectors, each equipped with an optimized diverging collimator. All simulations for designing and evaluating the 4D tracking system were performed using the open-source GATE (v9.1) Monte Carlo platform based on the GEANT4 (v10.7) toolkit. In addition, to evaluate the accuracy of the proposed 4D tracking system, we conducted simulations and 3D positioning using a solid phantom and patient data. Finally, the error between the reconstructed position coordinates determined by the tracking system and the original coordinates of the Ir-192 radiation source was analyzed. Results: The parameters for the optimized diverging collimator were a septal thickness of 0.3 mm and a collimator height of 30 mm. A tracking system comprising 6 compact detectors was designed and implemented utilizing this collimator. Analysis of the accuracy of the proposed Ir-192 source tracking system found that the average of the absolute values of the error between the 3D reconstructed and original positions for the simulation with the solid phantom were 0.440 mm for the x coordinate, 0.423 mm for the y coordinate, and 0.764 mm for the z coordinate, and the average Euclidean distance was 1.146 mm. Finally, in a simulation based on data from a patient who underwent brachytherapy, the average Euclidean distance between the original and reconstructed source position was 0.586 mm. Discussion: These results indicated that the newly designed in vivo 4D tracking system for monitoring the Ir-192 source during brachytherapy could determine the 3D position of the radiation source in real time during treatment. We conclude that the proposed positioning system has the potential to make brachytherapy more accurate and reliable.

3.
J Cancer Res Ther ; 20(1): 85-92, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38554303

ABSTRACT

INTRODUCTION: The purpose of this study was to evaluate a plastic scintillating plate-based beam monitoring system to perform quality assurance (QA) measurements in pencil beam scanning proton beam. METHODS: Single spots and scanned fields were measured with the high-resolution dosimetry system, consisting of a plastic scintillation plate coupled to a camera in a dark box at the isocenter. The measurements were taken at 110-190 MeV beam energies with 30° gantry angle intervals at each energy. Spot positions were determined using the plastic scintillating plate-based dosimetry system at the isocenter for 70-230 MeV beam energies with 30° gantry angle intervals. The effect of gantry angle on dose distribution was also assessed by determining the scanning pattern for daily QA and 25 fields treated with intensity-modulated proton therapy. RESULTS: Spot size, field flatness, and field symmetry of plastic scintillating plate-based dosimetry system were consistent with EBT3 at all investigated energies and angles. In all investigated energies and angles, the spot size measured was ±10% of the average size of each energy, the spot position measured was within ±2 mm, field flatness was within ±2%, and field symmetry was within ±1%. The mean gamma passing rates with the 3%/3 mm gamma criterion of the scanning pattern and 25 fields were 99.2% and 99.8%, respectively. CONCLUSIONS: This system can be effective for QA determinations of spot size, spot position, field flatness, and field symmetry over 360° of gantry rotation in a time- and cost-effective manner, with spatial resolution comparable to that of EBT3 film.


Subject(s)
Proton Therapy , Humans , Protons , Radiometry , Radiotherapy Dosage
4.
ACS Appl Mater Interfaces ; 16(8): 9725-9735, 2024 Feb 28.
Article in English | MEDLINE | ID: mdl-38378454

ABSTRACT

Potentiometric detection in complex biological fluids enables continuous electrolyte monitoring for personal healthcare; however, the commercialization of ion-selective electrode-based devices has been limited by the rapid loss of potential stability caused by electrode surface inactivation and biofouling. Here, we describe a simple multifunctional hybrid patch incorporating an Au nanoparticle/siloxene-based solid contact (SC) supported by a substrate made of laser-inscribed graphene on poly(dimethylsiloxane) for the noninvasive detection of sweat Na+ and K+. These SC nanocomposites prevent the formation of a water layer during ion-to-electron transfer, preserving 3 and 5 µV/h potential drift for the Na+ and K+ ion-selective electrodes, respectively, after 13 h of exposure. The lamellar structure of the siloxene sheets increases the SC area. In addition, the electroplated Au nanoparticles, which have a large surface area and excellent conductivity, further increased the electric double-layer capacitance at the interface between the ion-selective membranes and solid-state contacts, thus facilitating ion-to-electron transduction and ultimately improving the detection stability of Na+ and K+. Furthermore, the integrated temperature and electrocardiogram sensors in the flexible patch assist in monitoring body temperature and electrocardiogram signals, respectively. Featuring both electrochemical ion-selective and physical sensors, this patch offers immense potential for the self-monitoring of health.


Subject(s)
Graphite , Metal Nanoparticles , Graphite/chemistry , Gold/chemistry , Sweat/chemistry , Metal Nanoparticles/chemistry , Electrocardiography
6.
Cancers (Basel) ; 15(13)2023 Jul 02.
Article in English | MEDLINE | ID: mdl-37444573

ABSTRACT

(1) In this study, we developed a deep learning (DL) model that can be used to predict late bladder toxicity. (2) We collected data obtained from 281 uterine cervical cancer patients who underwent definitive radiation therapy. The DL model was trained using 16 features, including patient, tumor, treatment, and dose parameters, and its performance was compared with that of a multivariable logistic regression model using the following metrics: accuracy, prediction, recall, F1-score, and area under the receiver operating characteristic curve (AUROC). In addition, permutation feature importance was calculated to interpret the DL model for each feature, and the lightweight DL model was designed to focus on the top five important features. (3) The DL model outperformed the multivariable logistic regression model on our dataset. It achieved an F1-score of 0.76 and an AUROC of 0.81, while the corresponding values for the multivariable logistic regression were 0.14 and 0.43, respectively. The DL model identified the doses for the most exposed 2 cc volume of the bladder (BD2cc) as the most important feature, followed by BD5cc and the ICRU bladder point. In the case of the lightweight DL model, the F-score and AUROC were 0.90 and 0.91, respectively. (4) The DL models exhibited superior performance in predicting late bladder toxicity compared with the statistical method. Through the interpretation of the model, it further emphasized its potential for improving patient outcomes and minimizing treatment-related complications with a high level of reliability.

7.
ACS Nano ; 17(9): 8355-8366, 2023 05 09.
Article in English | MEDLINE | ID: mdl-37012260

ABSTRACT

Electronic gloves (e-gloves), with their multifunctional sensing capability, hold a promising application in robotic skin and human-machine interfaces, endowing robots with a human sense of touch. Despite the progress in developing e-gloves by exploiting flexible or stretchable sensors, existing models have inherent rigidity in their sensing area, limiting their stretchability and sensing performance. Herein, we present an all-directional strain-insensitive stretchable e-glove that successfully extends sensing functionality such as pressure, temperature, humidity, and ECG with minimal crosstalk. A scalable and facile method is successfully demonstrated by combining low-cost CO2 laser engraving and electrospinning technology to fabricate multimodal e-glove sensors with a vertical architecture. In comparison to other smart gloves, the proposed e-glove features a ripple-like meandering sensing area and interconnections that are designed to stretch in response to the applied deformation, without affecting the performance of the sensors offering full mechanical stretchability. Furthermore, CNT-coated laser-engraved graphene (CNT/LEG) is used as an active sensing material in which the cross-linking network of the CNT in the LEG minimizes the stress effect and maximizes the sensitivity of the sensors. The fabricated e-glove can detect hot/cold, moisture, and pain simultaneously and precisely, while also allowing for remote transmission of sensory data to the user.


Subject(s)
Robotic Surgical Procedures , Robotics , Humans , Skin , Touch
8.
Foods ; 12(6)2023 Mar 15.
Article in English | MEDLINE | ID: mdl-36981173

ABSTRACT

The dissipation patterns of chlorfenapyr, cyenopyrafen, indoxacarb, and spirotetramat on strawberries and the effects of different household washing methods were investigated. A risk assessment was also conducted by monitoring the insecticide residues detected. The concentrations ranged from 0.011 to 0.27 mg/kg for chlorfenapyr, 0.064 to 0.99 mg/kg for cyenopyrafen, 0.042 to 0.53 mg/kg for indoxacarb, and from 0.25 to 1.3 mg/kg for spirotetramat, which were all below the maximum residue limits (MRLs) reported. Soaking the fruit in solution and then rinsing with running water (B) led to better residue removal (40.9 ± 23.7%) than only soaking in solution (A) (24.7 ± 22.5%). However, neither method decreased chlorfenapyr concentrations, suggesting that the physical-chemical properties of chlorfenapyr could also affect its removal on strawberries. Regarding the different washing solutions in method B, 3% vinegar (removal efficiency: 48.7%) and 3% salt (45.7%) were the most efficient, followed by 3% green tea (38.9%), and tap water only (24.6%). Additionally, the estimated risk quotients (RQs) for strawberry consumption for women were about 1.5 times higher than those observed for men, but both were lower than 1, suggesting minimal risk to humans.

9.
ACS Appl Mater Interfaces ; 15(1): 1475-1485, 2023 Jan 11.
Article in English | MEDLINE | ID: mdl-36571793

ABSTRACT

The development of highly sensitive, reliable, and cost-effective strain sensors is a big challenge for wearable smart electronics and healthcare applications, such as soft robotics, point-of-care systems, and electronic skins. In this study, we newly fabricated a highly sensitive and reliable piezoresistive strain sensor based on polyhedral cobalt nanoporous carbon (Co-NPC)-incorporated laser-induced graphene (LIG) for wearable smart healthcare applications. The synergistic integration of Co-NPC and LIG enables the performance improvement of the strain sensor by providing an additional conductive pathway and robust mechanical properties with a high surface area of Co-NPC nanoparticles. The proposed porous graphene nanosheets exploited with Co-NPC nanoparticles demonstrated an outstanding sensitivity of 1,177 up to a strain of 18%, which increased to 39,548 beyond 18%. Additionally, the fabricated sensor exhibited an ultralow limit of detection (0.02%) and excellent stability over 20,000 cycles even under high strain conditions (10%). Finally, we successfully demonstrated and evaluated the sensor performance for practical use in healthcare wearables by monitoring wrist pulse, neck pulse, and joint flexion movement. Owing to the outstanding performance of the sensor, the fabricated sensor has great potential in electronic skins, human-machine interactions, and soft robotics applications.


Subject(s)
Graphite , Nanopores , Wearable Electronic Devices , Humans , Carbon , Delivery of Health Care
10.
Med Phys ; 50(1): 557-569, 2023 Jan.
Article in English | MEDLINE | ID: mdl-35993665

ABSTRACT

PURPOSE: A real-time solar cell based in vivo dosimetry system (SC-IVD) was developed using a flexible thin film solar cell and scintillating powder. The present study evaluated the clinical feasibility of the SC-IVD in electron beam therapy. METHODS: A thin film solar cell was coated with 100 mg of scintillating powder using an optical adhesive to enhance the sensitivity of the SC-IVD. Calibration factors were obtained by dividing the dose, measured at a reference depth for 6-20 MeV electron beam energy, by the signal obtained using the SC-IVD. Dosimetric characteristics of SC-IVDs containing variable quantities of scintillating powder (0-500 mg) were evaluated, including energy, dose rate, and beam angle dependencies, as well as dose linearity. To determine the extent to which the SC-IVD affected the dose to the medium, doses at R90 were compared depending on whether the SC-IVD was on the surface. Finally, the accuracy of surface doses measured using the SC-IVD was evaluated by comparison with surface doses measured using a Markus chamber. RESULTS: Charge measured using the SC-IVD increased linearly with dose and was within 1% of the average signal according to the dose rate. The signal generated by the SC-IVD increased as the beam angle increased. The presence of the SC-IVD on the surface of a phantom resulted in a 0.5%-2.2% reduction in dose at R90 for 6-20 MeV electron beams compared with the bare phantom. Surface doses measured using the SC-IVD system and Markus chamber differed by less than 5%. CONCLUSIONS: The dosimetric characteristics of the SC-IVD were evaluated in this study. The results showed that it accurately measured the surface dose without a significant difference of dose in the medium when compared with the Markus chamber. The flexibility of the SC-IVD allows it to be attached to a patient's skin, enabling real-time and cost-effective measurement.


Subject(s)
Electrons , In Vivo Dosimetry , Humans , Powders , Radiometry/methods , Film Dosimetry/methods
11.
Med Phys ; 50(2): 1194-1204, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36135795

ABSTRACT

PURPOSE: The amount of luminescent light detected in a scintillator is reduced with increased proton linear energy transfer (LET) despite receiving the same proton dose, through a phenomenon called quenching. This study evaluated the ability of a solar cell coated with scintillating powder (SC-SP) to measure therapeutic proton LET by measuring the quenching effect of the scintillating powder using a solar cell while simultaneously measuring the dose of the proton beam. METHODS: SC-SP was composed of a flexible thin film solar cell and scintillating powder. The LET and dose of the pristine Bragg peak in the 14 cm range were calculated using a validated Monte Carlo model of a double scattering proton beam nozzle. The SC-SP was evaluated by measuring the proton beam under the same conditions at specific depths using SC-SP and Markus chamber. Finally, the 10 and 20 cm range pristine Bragg peaks and 5 cm spread-out Bragg peak (SOBP) in the 14 cm range were measured using the SC-SP and the Markus chamber. LETs measured using the SC-SP were compared with those calculated using Monte Carlo simulations. RESULTS: The quenching factors of the SC-SP and solar cell alone, which were slopes of linear fit obtained from quenching correction factors according to LET, were 0.027 and 0.070 µm/keV (R2 : 0.974 and 0.975). For pristine Bragg peaks in the 10 and 20 cm ranges, the maximum differences between LETs measured using the SC-SP and calculated using Monte Carlo simulations were 0.5 keV/µm (15.7%) and 1.2 keV/µm (12.0%), respectively. For a 5 cm SOBP proton beam, the LET measured using the SC-SP and calculated using Monte Carlo simulations differed by up to 1.9 keV/µm (18.7%). CONCLUSIONS: Comparisons of LETs for pristine Bragg peaks and SOBP between measured using the SC-SP and calculated using Monte Carlo simulations indicated that the solar cell-based system could simultaneously measure both LET and dose in real-time and is cost-effective.


Subject(s)
Proton Therapy , Protons , Powders , Linear Energy Transfer , Monte Carlo Method
12.
Cancers (Basel) ; 14(23)2022 Nov 29.
Article in English | MEDLINE | ID: mdl-36497374

ABSTRACT

This research addresses the problem of interobserver variability (IOV), in which different oncologists manually delineate varying primary gross tumor volume (pGTV) contours, adding risk to targeted radiation treatments. Thus, a method of IOV reduction is urgently needed. Hypothesizing that the radiation oncologist's IOV may shrink with the aid of IOV maps, we propose IOV prediction network (IOV-Net), a deep-learning model that uses the fuzzy membership function to produce high-quality maps based on computed tomography (CT) images. To test the prediction accuracy, a ground-truth pGTV IOV map was created using the manual contour delineations of radiation therapy structures provided by five expert oncologists. Then, we tasked IOV-Net with producing a map of its own. The mean squared error (prediction vs. ground truth) and its standard deviation were 0.0038 and 0.0005, respectively. To test the clinical feasibility of our method, CT images were divided into two groups, and oncologists from our institution created manual contours with and without IOV map guidance. The Dice similarity coefficient and Jaccard index increased by ~6 and 7%, respectively, and the Hausdorff distance decreased by 2.5 mm, indicating a statistically significant IOV reduction (p < 0.05). Hence, IOV-net and its resultant IOV maps have the potential to improve radiation therapy efficacy worldwide.

13.
Materials (Basel) ; 15(22)2022 Nov 14.
Article in English | MEDLINE | ID: mdl-36431513

ABSTRACT

Three- or two-dimensional (2D) numerical models are used for the evaluation of the seismic performance of reinforced concrete (RC) buildings. This study examines a 2D numerical model for a specimen used in a full-scale four-story RC shaking-table test and evaluates the accuracy of the seismic response of the 2D numerical model, which is composed of a square fiber section model for the columns, a T-shape fiber section model for the beam and slab, and a rigid joint model for the beam-column joint. A parametric analysis of the effective slab width is performed to analyze its effects on the modal shape and natural period. The results suggest that the primary natural period of the considered model is almost identical to that associated with the experimental results. The applicability of the 2D numerical model for estimating the seismic response of the structure is established. By comparing the results of the seismic analysis and the experiment in the 50% amplitude of the JMA-Kobe wave, which corresponds to slightly exceeding VII on the modified Mercalli intensity scale, the root-mean-square percentage error of the 2D numerical model is 1.03% for the floor acceleration and 4.7% for the inter-story drift. Thus, the analytical model used in this study has sufficient accuracy in evaluating the seismic performance of buildings constructed in regions with a maximum seismic intensity of VII.

14.
Med Phys ; 49(7): 4768-4779, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35396722

ABSTRACT

PURPOSE: To evaluate the dosimetric characteristics and applications of a dosimetry system composed of a flexible amorphous silicon thin-film solar cell and scintillator screen (STFSC-SS) for therapeutic X-rays. METHODS: The real-time dosimetry system was composed of a flexible a-Si thin-film solar cell (0.2-mm thick), a scintillator screen to increase its efficiency, and an electrometer to measure the generated charge. The dosimetric characteristics of the developed system were evaluated including its energy dependence, dose linearity, and angular dependence. Calibration factors for the signal measured by the system and absorbed dose-to-water were obtained by setting reference conditions. The application and correction accuracy of the developed system were evaluated by comparing the absorbed dose-to-water measured using a patient treatment beam with that measured using the ion chamber. RESULTS: The responses of STFSC-SS to energy, field size, depth, and source-to-surface distance (SSD) were more dependent on measurement conditions than were the responses of the ion chamber, although the former dependence was due to the scintillator screen, not the solar cell. The signals of STFSC-SS were also dependent on dose rate, while the responses of solar cell alone and scintillator screen were not dependent on dose rate. The scintillator screen reduced the output of solar cell at 6 and 15 MV by 0.60 and 0.55%, respectively. The different absorbed dose-to-water measured using STFSC-SS for patient treatment beam differed by 0.4% compared to those measured using the ionization chamber. The uncertainties of the developed system for 6 and 15 MV photon beams were 1.8 and 1.7%, respectively, confirming the accuracy and applicability of this system. CONCLUSIONS: The thin-film solar cell-based detector developed in this study can accurately measure absorbed dose-to-water. The increased signal resulting from the use of the scintillator screen is advantageous for measuring low doses and stable signal output. In addition, this system is flexible, making it applicable to curved surfaces, such as a patient's body, and is cost-effective.


Subject(s)
Radiometry , Silicon , Humans , Radiography , Radiometry/methods , Water , X-Rays
15.
Front Oncol ; 11: 707464, 2021.
Article in English | MEDLINE | ID: mdl-34595112

ABSTRACT

To automatically identify optimal beam angles for proton therapy configured with the double-scattering delivery technique, a beam angle optimization method based on a convolutional neural network (BAODS-Net) is proposed. Fifty liver plans were used for training in BAODS-Net. To generate a sequence of input data, 25 rays on the eye view of the beam were determined per angle. Each ray collects nine features, including the normalized Hounsfield unit and the position information of eight structures per 2° of gantry angle. The outputs are a set of beam angle ranking scores (S beam) ranging from 0° to 359°, with a step size of 1°. Based on these input and output designs, BAODS-Net consists of eight convolution layers and four fully connected layers. To evaluate the plan qualities of deep-learning, equi-spaced, and clinical plans, we compared the performances of three types of loss functions and performed K-fold cross-validation (K = 5). For statistical analysis, the volumes V27Gy and V30Gy as well as the mean, minimum, and maximum doses were calculated for organs-at-risk by using a paired-samples t-test. As a result, smooth-L1 loss showed the best optimization performance. At the end of the training procedure, the mean squared errors between the reference and predicted S beam were 0.031, 0.011, and 0.004 for L1, L2, and smooth-L1 loss, respectively. In terms of the plan quality, statistically, PlanBAO has no significant difference from PlanClinic (P >.05). In our test, a deep-learning based beam angle optimization method for proton double-scattering treatments was developed and verified. Using Eclipse API and BAODS-Net, a plan with clinically acceptable quality was created within 5 min.

16.
J Agric Food Chem ; 69(33): 9536-9544, 2021 Aug 25.
Article in English | MEDLINE | ID: mdl-34293861

ABSTRACT

Methiozolin is a novel herbicide used to control annual bluegrass. It has low vapor pressure and high hydrophobicity, which could result in persistence in water and bioaccumulation. We measured the bioconcentration factors (BCFs) of methiozolin in ricefish (Oryzias latipes). Two radiolabels were used to quantify the parent compound and identify its metabolites. Ricefish were exposed to 2.0 and 20.0 ng/L methiozolin for 28 days in the uptake phase with a 96-h LC50 of 2.2 mg/L(95% confidence limit: 2.1-2.5 mg/L) and water solubility of 4.2 mg/L after 48 h was observed. On the basis of total radioactivity residues (TRRs), BCFss and BCFk values of 797.0-851.9 and 992.9-1077.4 were observed, respectively, while BCFss values for methiozolin were 251.9-257.5. Several minor metabolites with TRR < 3.4% were detected. Among them, 4-(2,6-difluorobenzyloxy-methyl)-3-hydroxy-3-methyl-1-(3-methylthiophen-2-yl)butan-1-one, 2,6-difluorobenzyl alcohol, and 4,5-dihydro-5-methyl-3-(3-methylthiophen-2-yl)isoxazol-5-yl)methanol were identified. Methiozolin is metabolized into numerous minor metabolites with potentially low bioaccumulation capacity in ricefish. These findings can facilitate risk assessments regarding methiozolin use, particularly its movements and final stages in aquatic environments.


Subject(s)
Herbicides , Oryzias , Water Pollutants, Chemical , Animals , Bioaccumulation , Isoxazoles , Thiophenes
17.
Radiat Oncol ; 16(1): 108, 2021 Jun 12.
Article in English | MEDLINE | ID: mdl-34118968

ABSTRACT

BACKGROUND: The purpose of this study is to develop a clinical application program that automatically calculates the effect for secondary cancer risk (SCR) of individual patient. The program was designed based on accurate dose calculations using patient computed tomography (CT) data and Monte Carlo engine. Automated patient-specific evaluation program was configured to calculate SCR. METHODS: The application program is designed to re-calculate the beam sequence of treatment plan using the Monte Carlo engine and patient CT data, so it is possible to accurately calculate and evaluate scatter and leakage radiation, difficult to calculate in TPS. The Monte Carlo dose calculation system was performed through stoichiometric calibration using patient CT data. The automatic SCR evaluation program in application program created with a MATLAB was set to analyze the results to calculate SCR. The SCR for organ of patient was calculated based on Biological Effects of Ionizing Radiation (BEIR) VII models. The program is designed to sequentially calculate organ equivalent dose (OED), excess absolute risk (EAR), excess relative risk (ERR), and the lifetime attributable risk (LAR) in consideration of 3D dose distribution analysis. In order to confirm the usefulness of the developed clinical application program, the result values from clinical application program were compared with the manual calculation method used in the previous study. RESULTS: The OED values calculated in program were calculated to be at most approximately 13.3% higher than results in TPS. The SCR result calculated by the developed clinical application program showed a maximum difference of 1.24% compared to the result of the conventional manual calculation method. And it was confirmed that EAR, ERR and LAR values can be easily calculated by changing the biological parameters. CONCLUSIONS: We have developed a patient-specific SCR evaluation program that can be used conveniently in the clinic. The program consists of a Monte Carlo dose calculation system for accurate calculation of scatter and leakage radiation and a patient-specific automatic SCR evaluation program using 3D dose distribution. The clinical application program that improved the disadvantages of the existing process can be used as an index for evaluating a patient treatment plan.


Subject(s)
Algorithms , Monte Carlo Method , Neoplasms, Radiation-Induced/etiology , Organs at Risk/radiation effects , Phantoms, Imaging , Radiotherapy, Intensity-Modulated/adverse effects , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Neoplasms, Radiation-Induced/pathology , Prognosis , Radiotherapy Dosage
18.
Phys Med ; 77: 181-186, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32871459

ABSTRACT

PURPOSE: The entrance beam fluence of therapeutic proton scanning beams can be monitored using a gantry-attachable plastic scintillating plate (GAPSP). This study evaluated the clinical application of the GAPSP using a method that measures intensity modulated proton therapy (IMPT) beams for patient treatment. METHODS: IMPT beams for the treatment of nine patients, at sites that included the spine, head and neck, pelvis, and lung, were measured using the GAPSP, composed of an EJ-212 plastic scintillator and a CMOS camera. All energy layers distinguished by the GAPSP were accumulated to determine the dose distribution of the treatment field. The evaluated fields were compared with reference dose maps verified by quality assurance. RESULTS: Comparison of dose distributions of evaluation treatment fields with reference dose distributions showed that the 3%/1 mm average gamma passing rate was 96.4%, independent of the treatment site, energy range and field size. When dose distributions were evaluated using the same criteria for each energy layer, the average gamma passing rate was 91.7%. CONCLUSIONS: The GAPSP is a suitable, low-cost method for monitoring pencil beam scanning proton therapy, especially for non-spot scanning or additional collimation. The GAPSP can also estimate the treatment beam by the energy layer, a feature not common to other proton dosimetry tools.


Subject(s)
Proton Therapy , Radiotherapy, Intensity-Modulated , Humans , Plastics , Protons , Radiometry , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted
19.
Psychiatry Investig ; 17(5): 403-411, 2020 May.
Article in English | MEDLINE | ID: mdl-32295328

ABSTRACT

OBJECTIVE: Problematic online gaming (POG) and problematic Internet use (PIU) have become a serious public mental health problem, with Internet gaming disorder (IGD) included in "Conditions for further study" section of DSM-5. Although higher immersive tendency is observed in people affected by POG, little is known about the simultaneous effect of immersive tendency and its highly comorbid mental disorder, attention deficit/hyperactivity disorder (ADHD). This study aimed to assess the relationship between immersive tendency, ADHD, and IGD. METHODS: Cross-sectional interview study was conducted in Seoul, Korea with 51 male undergraduate students; 23 active gamers and 28 controls. RESULTS: Current ADHD symptoms showed partial mediation effect on the path of immersive tendency on POG and PIU. The mediation model with inattention explained variance in both POG and PIU better than other current ADHD symptom models (R2=69.2 in POG; 69.3 in PIU). Childhood ADHD symptoms models demonstrated mediation effect on both POG and PIU which explained less variance than current ADHD symptom models (R2=53.7 in POG; 52.1 in PIU). Current ADHD symptoms, especially inattention, appear to mediate the effect of immersive tendency on POG/PIU. CONCLUSION: Immersive tendencies may entail greater susceptibility to IGD, and comorbidity with ADHD may mediate the effect of immersive tendency on IGD.

20.
Med Phys ; 47(2): 703-712, 2020 Feb.
Article in English | MEDLINE | ID: mdl-31732965

ABSTRACT

PURPOSE: The purpose of this study was to describe a plastic scintillating plate-based gantry-attachable dosimetry system for pencil beam scanning proton therapy to monitor entrance proton beam fluence, and to evaluate the dosimetric characteristics of this system and its feasibility for clinical use. METHODS: The dosimetry system, consisting of a plastic scintillating plate and a CMOS camera, was attached to a dedicated scanning nozzle and scintillation during proton beam irradiation was recorded. Dose distribution was calculated from the accumulated recorded frames. The dosimetric characteristics (energy dependency, dose linearity, dose rate dependency, and reproducibility) of the gantry-attachable dosimetry system for use with therapeutic proton beams were measured, and the feasibility of this system during clinical use was evaluated by determining selected quality assurance items at our institution. RESULTS: The scintillating plate shortened the range of the proton beam by the water-equivalent thickness of the plate and broadened the spatial profile of the single proton spot by 11% at 70 MeV. The developed system functioned independently of the beam energy (<1.3%) and showed dose linearity, and also functioned independently of the dose rate. The feasibility of the system for clinical use was evaluated by comparing the measured quality assurance dose distribution to that of the treatment planning system. The gamma passing rate with a criterion of 3%/3 mm was 97.58%. CONCLUSIONS: This study evaluated the dosimetric characteristics of a plastic scintillating plate-based dosimetry system for use with scanning proton beams. The ability to account for the interference of the dosimetry system on the therapeutic beam enabled offline monitoring of the entrance beam fluence of the pencil beam scanning proton therapy independent of the treatment system with high resolution and in a cost-effective manner.


Subject(s)
Plastics/chemistry , Proton Therapy/methods , Radiometry/methods , Scintillation Counting/methods , Equipment Design , Feasibility Studies , Humans , Models, Theoretical , Phantoms, Imaging , Proton Therapy/instrumentation , Radiometry/instrumentation , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Reproducibility of Results , Scintillation Counting/instrumentation , Water