Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 18(12)2018 Dec 19.
Article in English | MEDLINE | ID: mdl-30572644

ABSTRACT

Electrocardiogram signal analysis is based on detecting a fiducial point consisting of the onset, offset, and peak of each waveform. The accurate diagnosis of arrhythmias depends on the accuracy of fiducial point detection. Detecting the onset and offset fiducial points is ambiguous because the feature values are similar to those of the surrounding sample. To improve the accuracy of this paper's fiducial point detection, the signal is represented by a small number of vertices through a curvature-based vertex selection technique using polygonal approximation. The proposed method minimizes the number of candidate samples for fiducial point detection and emphasizes these sample's feature values to enable reliable detection. It is also sensitive to the morphological changes of various QRS complexes by generating an accumulated signal of the amplitude change rate between vertices as an auxiliary signal. To verify the superiority of the proposed algorithm, error distribution is measured through comparison with the QT-DB annotation provided by Physionet. The mean and standard deviation of the onset and the offset were stable as - 4.02 ± 7.99 ms and - 5.45 ± 8.04 ms, respectively. The results show that proposed method using small number of vertices is acceptable in practical applications. We also confirmed that the proposed method is effective through the clustering of the QRS complex. Experiments on the arrhythmia data of MIT-BIH ADB confirmed reliable fiducial point detection results for various types of QRS complexes.

2.
Sensors (Basel) ; 17(3)2017 Feb 23.
Article in English | MEDLINE | ID: mdl-28241464

ABSTRACT

This paper presents a pan-tilt-zoom (PTZ) camera-based displacement measurement system, specially based on the perspective distortion correction technique for the early detection of building destruction. The proposed PTZ-based vision system rotates the camera to monitor the specific targets from various distances and controls the zoom level of the lens for a constant field of view (FOV). The proposed approach adopts perspective distortion correction to expand the measurable range in monitoring the displacement of the target structure. The implemented system successfully obtains the displacement information in structures, which is not easily accessible on the remote site. We manually measured the displacement acquired from markers which is attached on a sample of structures covering a wide geographic region. Our approach using a PTZ-based camera reduces the perspective distortion, so that the improved system could overcome limitations of previous works related to displacement measurement. Evaluation results show that a PTZ-based displacement sensor system with the proposed distortion correction unit is possibly a cost effective and easy-to-install solution for commercialization.

SELECTION OF CITATIONS
SEARCH DETAIL
...