Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Part Ther ; 7(4): 42-51, 2021.
Article in English | MEDLINE | ID: mdl-33829072

ABSTRACT

PURPOSE: Periorbital tumor location presents a significant challenge with 3-dimensional conformal radiation therapy or intensity modulated radiation therapy due to high tumor dose needed in the setting of close proximity to orbital structures with lower tolerance. Proton beam therapy (PBT) is felt to be an effective modality in such cases due to its sharp dose gradient. MATERIALS AND METHODS: We reviewed our institutional PBT registry and identified 17 patients with tumor epicenters within 2 cm of the eye and optic apparatus treated with passive scatter PBT with comparison volumetric arc therapy plans available. Maximum and mean doses to organs at risk of interest, including optic nerves, optic chiasm, lens, eye ball, pituitary, cochlea, lacrimal gland, and surrounding brain, were compared using the paired Wilcoxon signed rank test. Overall survival was determined using the Kaplan-Meier method. RESULTS: Median age was 67. Median follow-up was 19.7 months. Fourteen patients underwent upfront resection and received postoperative radiation and 3 received definitive radiation. One patient received elective neck radiation, 2 underwent reirradiation, and 3 had concurrent chemotherapy. There was a statistically significant reduction in mean dose to the optic nerves and chiasm, brain, pituitary gland, lacrimal glands, and cochlea as well as in the maximum dose to the optic nerves and chiasm, pituitary gland, lacrimal glands, and cochlea with PBT. The 18-month cumulative incidence of local failure was 19.1% and 1-year overall survival was 80.9%. CONCLUSION: Proton beam therapy resulted in significant dose reductions to several periorbital and optic structures compared with volumetric arc therapy. Proton beam therapy appears to be the optimal radiation modality in such cases to minimize risk of toxicity to periorbital organs at risk.

2.
Int J Part Ther ; 6(3): 13-18, 2020.
Article in English | MEDLINE | ID: mdl-32582810

ABSTRACT

PURPOSE: Reirradiation in the scalp area can be challenging given the proximity to organs at risk (OARs), such as the eye and brain. Our aim is to evaluate the dosimetric differences of volumetric modulated arc therapy (VMAT) and electron beam therapy (EBT) compared with 3-dimensional proton beam therapy (PBT). PATIENTS AND METHODS: We evaluated a patient with recurrent angiosarcoma of the left temporal scalp after prior surgical resections and radiation therapy to 60 Gy in 30 fractions who needed reirradiation. We generated VMAT, EBT, and PBT plans using the Pinnacle Treatment Planning System (TPS). Both VMAT and EBT plans used a skin bolus, whereas no bolus was used for the proton plan. Doses to the OARs, including cochlea, eyes, lens, lacrimal glands, optic nerves, optic chiasm, pituitary gland, and underlying brain, were compared. RESULTS: The reirradiation treatment dose was 60 Gy(RBE). Target volume coverage was comparable in all plans. Compared with VMAT and EBT, the PBT plan showed reductions in mean and maximum doses to all OARs. Without the use of protons, several OARs would have exceeded dose tolerance utilizing VMAT or electrons. Dose reduction of up to 100% was achieved for central and contralateral OARs. CONCLUSION: Compared with VMAT and EBT, PBT resulted in dose reductions to all OARs, while maintaining excellent target coverage. PBT showed a significant advantage in treating superficially located skin cancers, such as angiosarcoma, without the need for a bolus. PBT can be considered in the upfront treatment and certainly in the reirradiation setting.

3.
J Appl Clin Med Phys ; 11(2): 3015, 2010 Apr 12.
Article in English | MEDLINE | ID: mdl-20592691

ABSTRACT

Large area, shallow fields are well suited to proton therapy. However, due to beam production limitations, such volumes typically require multiple matched fields. This is problematic due to the relatively narrow beam penumbra at shallow depths compared to electron and photon beams. Therefore, highly accurate dose planning and delivery is required. As the dose delivery includes shifting the patient for matched fields, accuracy at the 1-2 millimeter level in patient positioning is also required. This study investigates the dosimetric accuracy of such proton field matching by an innovative robotic patient positioner system (RPPS). The dosimetric comparisons were made between treatment planning system calculations, radiographic film and ionization chamber measurements. The results indicated good agreement amongst the methods and suggest that proton field matching by a RPPS is accurate and efficient.


Subject(s)
Neoplasms/radiotherapy , Patient Positioning , Proton Therapy , Radiometry , Radiotherapy/instrumentation , Robotics , Humans , Radiotherapy Dosage
SELECTION OF CITATIONS
SEARCH DETAIL
...