Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 25
Filter
1.
J Clin Med ; 10(15)2021 Jul 26.
Article in English | MEDLINE | ID: mdl-34362068

ABSTRACT

OBJECTIVES: The image quality of an Ultra-Low-Dose (ULD) chest CT depends on the patient's morphotype. We hypothesize that there is a threshold beyond which the diagnostic performance of a ULD chest CT is too degraded. This work assesses the influence of morphotype (Body Mass Index BMI, Maximum Transverse Chest Diameter MTCD and gender) on image quality and the diagnostic performance of a ULD chest CT. METHODS: A total of 170 patients from three prior prospective monocentric studies were retrospectively included. Renewal of consent was waived by our IRB. All the patients underwent two consecutive unenhanced chest CT acquisitions with a full dose (120 kV, automated tube current modulation) and a ULD (135 kV, fixed tube current at 10 mA). Image noise, subjective image quality and diagnostic performance for nine predefined lung parenchyma lesions were assessed by two independent readers, and correlations with the patient's morphotype were sought. RESULTS: The mean BMI was 26.6 ± 5.3; 20.6% of patients had a BMI > 30. There was a statistically significant negative correlation of the BMI with the image quality (ρ = -0.32; IC95% = (-0.468; -0.18)). The per-patient diagnostic performance of ULD was sensitivity, 77%; specificity, 99%; PPV, 94% and NPV, 65%. There was no statistically significant influence of the BMI, the MTCD nor the gender on the per-patient and per-lesion diagnostic performance of a ULD chest CT, apart from a significant negative correlation for the detection of emphysema. CONCLUSIONS: Despite a negative correlation between the BMI and the image quality of a ULD chest CT, we did not find a correlation between the BMI and the diagnostic performance of the examination, suggesting a possible use of the ULD protocol in obese patients.

2.
Eur Radiol ; 29(12): 6858-6866, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31175414

ABSTRACT

OBJECTIVES: Diagnostic performance and potential radiation dose reduction of wide-area detector CT sequential acquisition ("wide-volume" acquisition (WV)) in unenhanced chest examination are unknown. This study aims to assess the image quality, the diagnostic performance, and the radiation dose reduction of WV mode compared with the classical helical acquisition for lung parenchyma analysis in an ultra-low-dose (ULD) protocol. METHODS: After Institutional Review Board Approval and written informed consent, 64 patients (72% men; 67.6 ± 9.7 years old; BMI 26.1 ± 5.3 kg/m2) referred for a clinically indicated unenhanced chest CT were prospectively included. All patients underwent, in addition to a standard helical acquisition (120 kV, automatic tube current modulation), two ULD acquisitions (135 kV, fixed tube current at 10 mA): one in helical mode and one in WV mode. Image noise, subjective image quality (5-level Likert scale), and diagnostic performance for the detection of 9 predetermined parenchymal abnormalities were assessed by two radiologists and compared using the chi-square or Fisher non-parametric tests. RESULTS: Subjective image quality (4.2 ± 0.7 versus 4.2 ± 0.8, p = 0.56), image noise (41.7 ± 8 versus 40.9 ± 8.7, p = 0.3), and diagnostic performance were equivalent between ULD WV and ULD helical. Radiation dose was significantly lower for the ULD WV acquisition (mean dose-length product 14.1 ± 1.3 mGy cm versus 15.8 ± 1.3, p < 0.0001). CONCLUSION: An additional 11% dose reduction is achieved with the WV mode in ULD chest CT with fixed tube current, with equivalent image quality and diagnostic performance when compared with the helical acquisition. KEY POINTS: • Image quality and diagnostic performance of ultra-low-dose unenhanced chest CT are identical between wide-volume mode and the reference helical acquisition. • Wide-volume mode allows an additional radiation dose reduction of 11% (mean dose-length product 14.1 ± 1.3 mGy cm versus 15.8 ± 1.3, p < 0.0001).


Subject(s)
Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted/methods , Radiography, Thoracic/methods , Tomography, X-Ray Computed/methods , Adult , Aged , Aged, 80 and over , Clinical Protocols , Female , Humans , Male , Middle Aged , Prospective Studies , Reproducibility of Results , Tomography, Spiral Computed/methods
3.
PLoS One ; 13(9): e0204145, 2018.
Article in English | MEDLINE | ID: mdl-30212567

ABSTRACT

OBJECTIVE: To reduce the iodine load required for CT Transcatheter Aortic Valve Replacement (TAVR) planning on a 320-row scanner by acquiring the two CT TAVR steps (ECG-gated aortic root CTA and non-gated aorto-ilio-femoral CTA) within a single contrast media bolus injection. METHODS: 50 consecutive patients (82.6±6.9 years; 56% female) were prospectively enrolled and underwent a TAVR planning using a 320-row CT, with ECG-gated aortic root CTA immediately followed by a non-gated aorto-iliac acquisition, all within a single bolus of 40-70mL of Iohexol 350mgI/mL. The Iodine load, image quality, SNR, CNR and radiation dose were compared using a Mann-Whitney test to that of 24 consecutive patients (84.3±4.8 years, 58% female) previously imaged on a 64-row scanner with a conventional two-step protocol. RESULTS: Iodine load was reduced by 44%. All examinations were of diagnostic quality, with improvement of the aortic root CTA image quality (4.9±0.3 versus 4.6±0.5, p<0.01) and a non-significant decrease of the aorto-iliac CTA image quality (4.7±0.6 versus 4.9±0.3, p = 0.07). SNR and CNR were significantly improved in the aortic root CTA (14.0±5.3 and 10.4±4.5 versus 10.3±4.2 and 6.8±3.3, p<0.01 for both) and non-significantly higher in the aorto-iliac CTA (16.5±8.0 and 14.1±7.9 versus 14.7±5.5 and 12.5±5.0, p = 0.42 and p = 0.66). Total radiation dose was reduced by 32%. CONCLUSION: 320-row CT scanner enables a 44% reduction of iodine load in TAVR planning, while maintaining excellent aorto-ilio-femoral arterial enhancement and lowering radiation dose.


Subject(s)
Aorta/surgery , Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Computed Tomography Angiography/methods , Contrast Media/administration & dosage , Iodine/administration & dosage , Iohexol/administration & dosage , Aged , Aged, 80 and over , Aorta/diagnostic imaging , Aorta/pathology , Aortic Valve/diagnostic imaging , Aortic Valve/pathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/pathology , Computed Tomography Angiography/instrumentation , Electrocardiography , Female , Heart Valve Prosthesis , Humans , Iliac Artery/diagnostic imaging , Iliac Artery/pathology , Injections, Intravenous , Male , Prospective Studies , Radiation Dosage , Transcatheter Aortic Valve Replacement/methods
4.
Transpl Infect Dis ; 19(6)2017 Dec.
Article in English | MEDLINE | ID: mdl-28994171

ABSTRACT

Cladophialophora bantiana brain abscesses are rare, but are frequently and quickly lethal in transplanted patients. We report the case of a 63-year-old man who had undergone lung transplantation for chronic obstructive pulmonary disease and presented with headaches and a neurological deficit. Magnetic resonance imaging revealed multiple brain abscesses. C. bantiana was identified by DNA sequencing performed directly on cerebral tissue obtained by surgical biopsy. After 6 months of antifungal treatment, the brain abscesses were replaced by ischemic sequelae. The patient died suddenly 2 months later from a pulmonary bacterial infection. This is the second reported case of C. bantiana brain abscesses in a lung transplant recipient, to our knowledge, who experienced a long survival period with medical antifungal treatment alone. We review the literature and discuss our treatment.


Subject(s)
Ascomycota/isolation & purification , Brain Abscess/microbiology , Lung Transplantation/adverse effects , Pulmonary Disease, Chronic Obstructive/surgery , Antifungal Agents/therapeutic use , Biopsy , Brain/diagnostic imaging , Brain/pathology , Brain Abscess/diagnostic imaging , Brain Abscess/drug therapy , Brain Abscess/pathology , Central Nervous System Fungal Infections , Fatal Outcome , Humans , Hyphae/isolation & purification , Magnetic Resonance Imaging , Male , Middle Aged , Time Factors
5.
PLoS One ; 11(12): e0168979, 2016.
Article in English | MEDLINE | ID: mdl-28033378

ABSTRACT

OBJECTIVE: To evaluate the diagnostic performance of Ultra-Low-Dose Chest CT (ULD CT) for the detection of any asbestos-related lesions (primary endpoint) and specific asbestos-related abnormalities, i.e. non-calcified and calcified pleural plaques, diffuse pleural thickening, asbestosis and significant lung nodules (secondary endpoints). MATERIAL AND METHODS: 55 male patients (55.7±8.1 years old) with occupational asbestos exposure for at least 15 years and where CT screening was indicated were prospectively included. They all underwent a standard unenhanced chest CT (120kV, automated tube current modulation), considered as the reference, and an ULD CT (135kV, 10mA), both with iterative reconstruction. Two chest radiologists independently and blindly read the examinations, following a detailed protocol. Sensitivity, specificity, positive predictive value, negative predictive value, accuracy and error rate of ULD CT were calculated using the exact method of Pearson with a confidence interval of 95%. RESULTS: Radiation dose was 17.9±1.2mGy.cm (0.25mSv) for the ULD-CT versus 288.8 ±151mGy.cm (4mSv); p <2.2e-16. Prevalence of abnormalities was 20%. The ULD CT's diagnostic performance in joint reading was high for the primary endpoint (sensitivity = 90.9%, specificity = 100%, positive predictive value = 100%, negative predictive value = 97.8%), high for lung nodules, diffuse pleural thickening and calcified pleural plaques (sensitivity, specificity, PPV and NPV = 100%) and fair for asbestosis (sensitivity = 75%, specificity = 100%, PPV = 00%, NPV = 98.1%). Intra-reader accuracy between the ULD CT and the reference CT for the primary endpoint was 98% for the senior and 100% for the junior radiologist. Inter-reader agreement for the primary endpoint was almost perfect (Cohen's Kappa of 0.81). CONCLUSION: ULD CT in the screening of asbestos exposure related diseases has 90.9% sensitivity and 100% specificity, and could therefore be proposed as a first line examination.


Subject(s)
Asbestos/pharmacology , Lung Diseases/chemically induced , Lung Diseases/diagnostic imaging , Mass Screening , Pleural Diseases/chemically induced , Pleural Diseases/diagnostic imaging , Radiation Dosage , Adult , Aged , Aged, 80 and over , Humans , Image Interpretation, Computer-Assisted , Male , Middle Aged , Occupational Exposure/adverse effects , Prospective Studies , Radiation Exposure , Radiography, Thoracic
6.
PLoS One ; 11(9): e0163503, 2016.
Article in English | MEDLINE | ID: mdl-27669571

ABSTRACT

OBJECTIVES: To compare cine MR b-TFE sequences acquired before and after gadolinium injection, on a 3T scanner with a parallel RF transmission technique in order to potentially improve scanning time efficiency when evaluating LV function. METHODS: 25 consecutive patients scheduled for a cardiac MRI were prospectively included and had their b-TFE cine sequences acquired before and right after gadobutrol injection. Images were assessed qualitatively (overall image quality, LV edge sharpness, artifacts and LV wall motion) and quantitatively with measurement of LVEF, LV mass, and telediastolic volume and contrast-to-noise ratio (CNR) between the myocardium and the cardiac chamber. Statistical analysis was conducted using a Bayesian paradigm. RESULTS: No difference was found before or after injection for the LVEF, LV mass and telediastolic volume evaluations. Overall image quality and CNR were significantly lower after injection (estimated coefficient cine after > cine before gadolinium: -1.75 CI = [-3.78;-0.0305], prob(coef>0) = 0% and -0.23 CI = [-0.49;0.04], prob(coef>0) = 4%) respectively), but this decrease did not affect the visual assessment of LV wall motion (cine after > cine before gadolinium: -1.46 CI = [-4.72;1.13], prob(coef>0) = 15%). CONCLUSIONS: In 3T cardiac MRI acquired with parallel RF transmission technique, qualitative and quantitative assessment of LV function can reliably be performed with cine sequences acquired after gadolinium injection, despite a significant decrease in the CNR and the overall image quality.

9.
Presse Med ; 45(3): 291-301, 2016 Mar.
Article in French | MEDLINE | ID: mdl-26830922

ABSTRACT

Ultra-low dose chest CT (ULD-CT) is acquired at a radiation dose lowered to that of a PA and lateral chest X-ray. Its image quality is degraded, yet remains diagnostic in many clinical indications. Technological improvements, with iterative reconstruction at the foreground, allowed a strong increase in the image quality obtained with this examination, which is achievable on most recent (<5 years) scanner. Established clinical indications of ULD-CT are increasing, and its non-inferiority compared to the reference "full dose" chest CT are currently demonstrated for the detection of solid nodules, for asbestos-related pleural diseases screening and for the monitoring of infectious pneumonia. Its current limitations are the obese patients (BMI>35) and the interstitial pneumonia, situations in which their performances are insufficient.


Subject(s)
Lung Diseases/diagnostic imaging , Radiography, Thoracic/trends , Tomography, X-Ray Computed/methods , Asbestosis/diagnostic imaging , Contrast Media , Equipment Design , France , Humans , Image Processing, Computer-Assisted/methods , Image-Guided Biopsy , Lung/diagnostic imaging , Mediastinum/diagnostic imaging , Neoplasm Staging/methods , Obesity/complications , Pleura/diagnostic imaging , Pleural Neoplasms/diagnostic imaging , Public Health/legislation & jurisprudence , Radiation Dosage , Radiation Exposure , Radiography, Thoracic/instrumentation , Radiography, Thoracic/methods , Tomography, X-Ray Computed/adverse effects , Tomography, X-Ray Computed/instrumentation
10.
Echocardiography ; 33(3): 484-7, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26603830

ABSTRACT

A 26-year-old man with a history of bilateral lung transplantation for pulmonary cystic fibrosis 6 months before was admitted in our institution for acute heart failure. Cardiac magnetic resonance imaging (CMR) showed an increased aortic output, as aortic flow assessed by velocity mapping was twofold the pulmonary flow, an occluded superior vena cava (SVC), and enlarged azygos vein. A systemic-to-pulmonary vein fistula (SAPVF) was suspected. The selective angiography showed numerous fistulae between intercostals, thyro-cervical, internal mammary arteries and pulmonary veins. The thoracic CT performed before the CMR, which was initially considered as normal, showed well these arteriovenous fistulae after 3D MIP reconstruction. This particular observation highlights the great value of multimodality imaging for the diagnosis of this rare pathology. The MR velocity mapping is a noninvasive imaging technique of great interest to guide the diagnosis of arteriovenous fistulae, and further indicating more invasive complementary imaging modalities like selective arterial angiography.


Subject(s)
Arteriovenous Fistula/diagnostic imaging , Arteriovenous Fistula/etiology , Lung Transplantation/adverse effects , Multimodal Imaging/methods , Pulmonary Veins/abnormalities , Pulmonary Veins/diagnostic imaging , Adult , Arteriovenous Fistula/surgery , Echocardiography/methods , Humans , Magnetic Resonance Imaging, Cine/methods , Male , Pulmonary Veins/surgery , Radiography, Thoracic/methods , Treatment Outcome
11.
Eur Radiol ; 26(6): 1547-55, 2016 Jun.
Article in English | MEDLINE | ID: mdl-26373760

ABSTRACT

OBJECTIVE: To qualitatively and quantitatively compare different late gadolinium enhancement (LGE) sequences acquired at 3T with a parallel RF transmission technique. METHODS: One hundred and sixty participants prospectively enrolled underwent a 3T cardiac MRI with 3 different LGE sequences: 3D Phase-Sensitive Inversion-Recovery (3D-PSIR) acquired 5 minutes after injection, 3D Inversion-Recovery (3D-IR) at 9 minutes and 3D-PSIR at 13 minutes. All LGE-positive patients were qualitatively evaluated both independently and blindly by two radiologists using a 4-level scale, and quantitatively assessed with measurement of contrast-to-noise ratio and LGE maximal surface. Statistical analyses were calculated under a Bayesian paradigm using MCMC methods. RESULTS: Fifty patients (70 % men, 56yo ± 19) exhibited LGE (62 % were post-ischemic, 30 % related to cardiomyopathy and 8 % post-myocarditis). Early and late 3D-PSIR were superior to 3D-IR sequences (global quality, estimated coefficient IR > early-PSIR : -2.37 CI = [-3.46 ; -1.38], prob(coef > 0) = 0 % and late-PSIR > IR : 3.12 CI = [0.62 ; 4.41], prob(coef > 0) = 100 %), LGE surface estimated coefficient IR > early-PSIR: -0.09 CI = [-1.11; -0.74], prob(coef > 0) = 0 % and late-PSIR > IR : 0.96 CI = [0.77; 1.15], prob(coef > 0) = 100 %). Probabilities for late PSIR being superior to early PSIR concerning global quality and CNR were over 90 %, regardless of the aetiological subgroup. CONCLUSIONS: In 3T cardiac MRI acquired with parallel RF transmission technique, 3D-PSIR is qualitatively and quantitatively superior to 3D-IR. KEY POINTS: • Late gadolinium enhancement is an essential part of a cardiac MRI examination • PSIR and IR sequences are the two possible options for LGE imaging • At 3T with parallel RF transmission, PSIR sequences are significantly better • One LGE sequence is sufficient, allowing an optimization of the acquisition time.


Subject(s)
Cardiomyopathies/diagnostic imaging , Myocardial Ischemia/diagnostic imaging , Myocarditis/diagnostic imaging , Adult , Aged , Bayes Theorem , Contrast Media , Female , Humans , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging/methods , Male , Middle Aged , Organometallic Compounds , Probability , Prospective Studies
12.
Clin Med Insights Cardiol ; 8(Suppl 4): 1-11, 2014.
Article in English | MEDLINE | ID: mdl-25525401

ABSTRACT

T1 mapping is now a clinically feasible method, providing pixel-wise quantification of the cardiac structure's T1 values. Beyond focal lesions, well depicted by late gadolinium enhancement sequences, it has become possible to discriminate diffuse myocardial alterations, previously not assessable by noninvasive means. The strength of this method includes the high reproducibility and immediate clinical applicability, even without the use of contrast media injection (native or pre-contrast T1). The two most important determinants of native T1 augmentation are (1) edema related to tissue water increase (recent infarction or inflammation) and (2) interstitial space increase related to fibrosis (infarction scar, cardiomyopathy) or to amyloidosis. Conversely, lipid (Anderson-Fabry) or iron overload diseases are responsible for T1 reduction. In this pictorial review, the main features provided by native T1 mapping are discussed and illustrated, with a special focus on the awaited clinical purpose of this unique, promising new method.

13.
Ann Am Thorac Soc ; 11(7): 1025-31, 2014 Sep.
Article in English | MEDLINE | ID: mdl-25118847

ABSTRACT

RATIONALE: Cystic lung light chain deposition disease (LCDD) is a severe and rare form of nonamyloid kappa light chain deposits localized in the lung, potentially leading to end-stage respiratory insufficiency. OBJECTIVES: To assess the outcome after lung transplantation (LT) in this setting with particular attention to disease recurrence. METHODS: We conducted a retrospective multicenter study of seven patients who underwent LT for cystic lung LCDD in France between September 1992 and June 2012 in five centers. MEASUREMENTS AND MAIN RESULTS: In total, five females and two males (mean age, 39.1 ± 5.3 yr) underwent one single LT or seven double LT (one retransplantation). Before LT, the patients showed a constant obstructive ventilatory pattern with low carbon monoxide diffusing capacity and resting hypoxemia. Lung computed tomography revealed widespread cysts with occasional micronodulations. No extrapulmonary disease or plasma cell neoplasm was detected. The serum-free kappa/lambda light chain ratio was increased in three cases. The median follow-up after LT was 56 months (range, 1-110 mo). Kaplan-Meier survival was 85.7, 85.7, and 64.3% at 1, 3, and 5 years, respectively. Three patients died from multiorgan failure (n = 1), chronic rejection (n = 1), and breast cancer (n = 1) at 23 days, 56 months, and 96 months, respectively. At the end of follow-up, no patients showed recurrence on imaging or histopathology. CONCLUSIONS: This small case series confirms that cystic lung LCDD is a severe disease limited to the lung, affecting mostly young females. LT appears to be a good therapeutic option allowing for satisfactory long-term survival. We found no evidence of recurrence of the disease after LT.


Subject(s)
Cystic Fibrosis/diagnosis , Cystic Fibrosis/surgery , Immunoglobulin kappa-Chains/metabolism , Lung Transplantation/methods , Adult , Cystic Fibrosis/mortality , Female , Follow-Up Studies , Graft Rejection , Graft Survival , Humans , Kaplan-Meier Estimate , Lung Transplantation/mortality , Male , Respiratory Function Tests , Retrospective Studies , Risk Assessment , Sampling Studies , Severity of Illness Index , Survival Analysis , Treatment Outcome , Young Adult
14.
J Magn Reson Imaging ; 40(5): 1238-46, 2014 Nov.
Article in English | MEDLINE | ID: mdl-24925128

ABSTRACT

PURPOSE: To define which circumferential strain MR-tagging metrics of left intraventricular dyssynchrony better identifies patients with systolic dysfunction against control subjects. MATERIALS AND METHODS: One hundred fifty subjects were studied: (i) controls with ejection fraction (EF) > 55% (n = 84), (ii) patients with EF ≤ 55% not eligible for cardiac resynchronization therapy (CRT) (n = 52), and (iii) patients eligible for CRT according to the ESC guidelines (n = 14). Tagging cine MR-based circumferential filtered strain curves were extracted. Six dyssynchrony indices were studied: standard deviation (SD) of peak strain (SD_Ecc_ES), SD of time-to-peak (SD_TTP), strain delay index (LIM), regional variance vector (RVV), circumferential uniformity ratio estimate (CURE), and uniformity of strain TTP (US_TTP). RESULTS: All metrics show significant differences between the three groups (ANOVA, P < 10(-4) ) and are correlated with EF. Significantly higher AUC values of ROC curves between patients with normal vs. decreased EF were obtained with SD_TTP (0.998) and CURE (0.995). Agreement among different methods was fair to good (kappa 0.32 to 0.89). Interobserver variability was best for CURE (1.2%) and US_TTP (0.8%) while more than 3-times larger for other metrics. CONCLUSION: SD_TTP and CURE are the most discriminant dyssynchrony metrics for systolic dysfunction. However, taking into account the method's variability argues in favor of indices of uniformity of the strain, ie, CURE and US_TTP.


Subject(s)
Algorithms , Bundle-Branch Block/diagnosis , Bundle-Branch Block/physiopathology , Cardiac Resynchronization Therapy , Cardiomyopathy, Dilated/diagnosis , Cardiomyopathy, Dilated/physiopathology , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging, Cine/methods , Myocardial Ischemia/diagnosis , Myocardial Ischemia/physiopathology , Systole/physiology , Ventricular Dysfunction, Left/diagnosis , Adult , Aged , Bundle-Branch Block/therapy , Cardiac-Gated Imaging Techniques , Female , Humans , Male , Middle Aged , Observer Variation , Papillary Muscles/physiopathology , ROC Curve , Stress, Mechanical , Stroke Volume/physiology , Ventricular Dysfunction, Left/physiopathology , Ventricular Dysfunction, Left/therapy
15.
Neuroradiology ; 56(8): 621-7, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24829164

ABSTRACT

INTRODUCTION: Gadolinium-enhanced magnetic resonance imaging (MRI) is the gold standard for cerebral staging in thoracic oncology. We hypothesize that a minimalist examination, consisting of a single contrast-enhanced T1-weighted three-dimensional gradient-echo sequence (CE 3D-GRE), would be sufficient for the cerebral staging of nonsymptomatic lung cancer patients. METHODS: Seventy nonsymptomatic patients (50 % men; 62 years ± 10.2) referred for cerebral staging of a lung cancer were retrospectively included. All underwent a standard 3 T MRI examination with T1, FLAIR, T2* GRE, diffusion, and CE 3D-GRE sequences, for a total examination time of 20 min. The sole CE 3D-GRE (acquisition time: 6 min) was extracted and blindly interpreted by two radiologists in search of brain metastases. Hemorrhagic features of potential lesions and relevant incidental findings were also noted. Discrepant cases were reviewed by a third reader. The full MRI examination and follow-up studies were used as a reference to calculate sensitivity and specificity of the sole CE 3D-GRE. RESULTS: Thirty-eight point six percent (27 out of 70) of the patients had brain metastases. Performances and reader's agreement with the sole CE 3D-GRE sequence were excellent for the diagnosis of brain metastases (sensitivity=96.3 %, specificity=100 %, κ=0.91) and incidental findings (sensitivity=85.7 %, specificity=100 %, κ=0.62) but insufficient for the identification of hemorrhages within the metastases (sensitivity=33.3 %, specificity=85.7 %, κ=0.47). CONCLUSIONS: In the specific case of lung cancer, cerebral staging in nonsymptomatic patients can be efficiently achieved with a minimalistic protocol consisting of a single CE 3D-GRE sequence, completed if positive with a T2* sequence for hemorrhagic assessment, thus halving appointment delays.


Subject(s)
Brain Neoplasms/secondary , Carcinoma/secondary , Echo-Planar Imaging/methods , Imaging, Three-Dimensional/methods , Lung Neoplasms/pathology , Neuroendocrine Tumors/secondary , Aged , Asymptomatic Diseases , Contrast Media , Female , Humans , Male , Meglumine , Middle Aged , Neoplasm Staging , Organometallic Compounds , Retrospective Studies , Sensitivity and Specificity
16.
Clin Med Insights Cardiol ; 8(Suppl 4): 27-36, 2014.
Article in English | MEDLINE | ID: mdl-25788837

ABSTRACT

BACKGROUND: Few studies evaluated left ventricular (LV) involvement in arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C). The aim of this study is to determine the frequency, clinical presentation, and pattern of LV involvement in ARVD/C (LV-ARVD/C). METHODS: We retrospectively evaluated the cardiac magnetic resonance (CMR) in 202 patients referred between 2008 and 2012 to our institution, and we determined the presence or the absence of CMR criteria in the revised task force criteria 2010 for the diagnosis of ARVD/C. A total of 21 patients were diagnosed with ARVD/C according to the revised task force criteria 2010. All included patients had no previous history of myocarditis, acute coronary syndrome, or any other cardiac disease that could interfere with the interpretations of structural abnormalities. The LV involvement in ARVD/C was defined by the presence of one or more of the following criteria: LV end-diastolic volume (LVEDV; >95 mL/m(2)), LV ejection fraction (LVEF; <55%), LV late enhancement of gadolinium (LVLE) in a non-ischemic pattern, and LV wall motion abnormalities (WMAs). In the follow-up for the occurrence of cardiac death, ventricular tachycardia (VT) was obtained at a mean of 31 ± 20.6 months. RESULTS: A total of 21 patients had ARVD/C. The median age was 48 (33-63) years. In all, 11 patients (52.4%) had LV-ARVD/C. The demographic characteristics of patients with or without LV were similar. There was a higher frequency of left bundle-branch block (LBBB) VT morphology in ARVD/C (P = 0.04). In CMR, regional WMAs of right ventricle (RV) and RV ejection fraction (RVEF; <45%) were strongly correlated with LV-WMAs (r = 0.72, P = 0.02, r = 0.75, P = 0.02, respectively). RV late enhancement of gadolinium (RVLE) was associated with LV-WMs and LVLE (r = 0.7, P = 0.03; r = 0.8, P = 0.006). LVLE was associated with LV-WMAs, LVEF, and LVEDV (r = 0.9, P = 0.001; r = 0.8, P = 0.001; r = 0.8, P = 0.01). CONCLUSION: LV involvement in ARVD/C is common and frequently associated with moderate to severe right ventricular (RV) abnormalities. The impact of LV involvement in ARVD/C on the prognosis needs further investigations.

17.
Respiration ; 86(2): 100-8, 2013.
Article in English | MEDLINE | ID: mdl-23154264

ABSTRACT

BACKGROUND: The development of three-dimensional conformal radiotherapy (3D-RT) has enabled the restriction of the dose to normal lung, limiting radiation-induced lung injury. OBJECTIVES: This study was designed to describe the time course of lung function until 7.5 months after 3D-RT in patients with lung cancer, and assess the relationship between lung function changes and dose-volume histogram (DVH) analysis or computed tomography scan changes. Radiation doses were optimized according to recent guidelines. METHODS: Sixty-five lung cancer patients treated with 3D-RT agreed to participate in this prospective, hospital-based study. Lung volumes, forced expiratory volume in 1 s (FEV1) and diffusing capacity of the lung for carbon monoxide (DLCO) were measured before radiotherapy (RT), 10 weeks, 4 and 7.5 months after the beginning of 3D-RT. RESULTS: Eleven lung cancer patients (17%) developed grade 2-3 respiratory symptoms after RT. At 7.5 months, vital capacity (VC) was 96 ± 2%, total lung capacity (TLC) 95 ± 2%, FEV1 93 ± 2% and DLCO 90 ± 2% of the initial value. Only 15% of patients showed pulmonary function reduction > 20%. Patients with FEV1 or DLCO < 60% before RT did not show significant changes after RT. There were weak correlations between reduction of VC, TLC, FEV1 or DLCO and radiation dosimetric parameters and between reduction of VC or FEV1 and radiation-induced pneumonitis images. CONCLUSIONS: In lung cancer, the reduction of lung function within 7.5 months after 3D-RT was small and correlated, albeit weakly, with DVH parameters. Patients with initially impaired lung function showed tiny changes in spirometry and DLCO values.


Subject(s)
Carcinoma, Non-Small-Cell Lung/radiotherapy , Forced Expiratory Volume/radiation effects , Lung Neoplasms/radiotherapy , Radiotherapy, Conformal/methods , Carcinoma, Non-Small-Cell Lung/diagnosis , Carcinoma, Non-Small-Cell Lung/physiopathology , Dose-Response Relationship, Radiation , Female , Follow-Up Studies , Humans , Lung Neoplasms/diagnosis , Lung Neoplasms/physiopathology , Male , Middle Aged , Neoplasm Staging , Prospective Studies , Respiratory Function Tests , Time Factors , Tomography, X-Ray Computed , Treatment Outcome
19.
Radiographics ; 32(5): 1381-98, 2012.
Article in English | MEDLINE | ID: mdl-22977026

ABSTRACT

Magnetic resonance tagging is used to evaluate the dynamic deformation of lines or grids superimposed on the myocardium during the cardiac cycle. From these data, a specific postprocessing procedure provides two kinds of metrics: (a) three orthogonal components of myocardial motion (longitudinal, circumferential, and radial), and (b) rotation and torsion. Strain expresses the local myocardial deformation and is prone to important physiologic heterogeneities. Peak systolic strain is in the range of -15% to -20% for the longitudinal and circumferential components (fiber shortening) and 30%-40% for the radial component (wall thickening). The helical arrangement of myofibers that run in opposite directions at the epicardium and endocardium explains systolic twist (~15°). This torsion may be enhanced during the early stage of several diseases (eg, hypertrophic cardiomyopathy) or in heart failure with a normal left ventricular ejection fraction. Strain is generally impaired in ischemic heart disease and cardiomyopathy, but the most diagnostically significant finding is the early identification of contractile dysfunction on the basis of longitudinal and circumferential strain reduction in patients with apparently preserved systolic function. Thus, strain impairment appears to be a sensitive and promising marker of subclinical disease, with the potential for improving patient management.


Subject(s)
Algorithms , Elasticity Imaging Techniques/methods , Fiducial Markers , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Ventricular Dysfunction, Left/diagnosis , Aged , Aged, 80 and over , Female , Humans , Image Enhancement/methods , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity
20.
Eur Neurol ; 64(3): 169-77, 2010.
Article in English | MEDLINE | ID: mdl-20699617

ABSTRACT

Tacrolimus (TAC) is an immunosuppressant drug discovered in 1984 by Fujisawa Pharmaceutical Co., Ltd. This drug belongs to the group of calcineurin inhibitors, which has been proven highly effective in preventing acute rejection after transplantation of solid organs. However, neurotoxicity and nephrotoxicity are its major adverse effects. Posterior reversible encephalopathy syndrome (PRES) is the most severe and dramatic consequence of calcineurin inhibitor neurotoxicity. It was initially described by Hinchey et al. in 1996 [N Engl J Med 1996;334:494-450]. Patients typically present with altered mental status, headache, focal neurological deficits, visual disturbances, and seizures. Magnetic resonance imaging is the most sensitive imaging test to detect this. With the more deep-going studies done recently, we have learnt more about this entity. It was noted that this syndrome is frequently reversible, rarely limited to the posterior regions of the brain, and often located in gray matter and cortex as well as in white matter. Therefore, in this review, the focus is on the current understanding of clinical recognition, pathogenesis, neuroimaging and management of TAC-associated PRES after solid organ transplantation.


Subject(s)
Immunosuppressive Agents/adverse effects , Neurotoxicity Syndromes/etiology , Tacrolimus/adverse effects , Humans , Magnetic Resonance Imaging/methods , Neurotoxicity Syndromes/diagnosis , Neurotoxicity Syndromes/therapy , Organ Transplantation/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...