Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Opt Lett ; 40(24): 5786-9, 2015 Dec 15.
Article in English | MEDLINE | ID: mdl-26670512

ABSTRACT

We have developed a noncontact, photothermal materials characterization method based on visible-light speckle imaging. This technique is applied to remotely measure the infrared absorption spectra of materials and to discriminate materials based on their thermal conductivities. A wavelength-tunable (7.5-8.7 µm), intensity-modulated, quantum cascade pump laser and a continuous-wave 532 nm probe laser illuminate a sample surface such that the two laser spots overlap. Surface absorption of the intensity-modulated pump laser induces a time-varying thermoelastic surface deformation, resulting in a time-varying 532 nm scattering speckle field from the surface. The speckle modulation amplitude, derived from a series of visible camera images, is found to correlate with the amplitude of the surface motion. By tuning the pump laser's wavelength over a molecular absorption feature, the amplitude spectrum of the speckle modulation is found to correlate to the IR absorption spectrum. As an example, we demonstrate this technique for spectroscopic identification of thin polymeric films. Furthermore, by adjusting the rate of modulation of the pump beam and measuring the associated modulation transfer to the visible speckle pattern, information about the thermal time constants of surface and sub-surface features can be revealed. Using this approach, we demonstrate the ability to distinguish between different materials (including metals, semiconductors, and insulators) based on differences in their thermal conductivities.

2.
Opt Express ; 20(11): 11953-67, 2012 May 21.
Article in English | MEDLINE | ID: mdl-22714181

ABSTRACT

We present an approach for rational design and optimization of plasmonic arrays for ultrasensitive surface enhanced infrared absorption (SEIRA) spectroscopy of specific protein analytes. Motivated by our previous work that demonstrated sub-attomole detection of surface-bound silk fibroin [Proc. Natl. Acad. Sci. U.S.A. 106, 19227 (2009)], we introduce here a general framework that allows for the numerical optimization of metamaterial sensor designs in order to maximize the absorbance signal. A critical feature of our method is the explicit compensation for the perturbative effects of the analyte's refractive index which alters the resonance frequency and line-shape of the metamaterial response, thereby leading to spectral distortion in SEIRA signatures. As an example, we leverage our method to optimize the geometry of periodic arrays of plasmonic nanoparticles on both Si and CaF2 substrates. The optimal geometries result in a three-order of magnitude absorbance enhancement compared to an unstructured Au layer, with the CaF2 substrate offering an additional factor of three enhancement in absorbance over a traditional Si substrate. The latter improvement arises from increase of near-field intensity over the Au nanobar surface for the lower index substrate. Finally, we perform sensitivity analysis for our optimized arrays to predict the effects of fabrication imperfections. We find that <20% deviation from the optimized absorbance response is readily achievable over large areas with modern nanofabrication techniques.


Subject(s)
Computer-Aided Design , Models, Theoretical , Nanotechnology/instrumentation , Refractometry/instrumentation , Spectrophotometry, Infrared/instrumentation , Surface Plasmon Resonance/instrumentation , Computer Simulation , Equipment Design , Equipment Failure Analysis , Light , Scattering, Radiation
3.
Opt Express ; 19(12): 11202-12, 2011 Jun 06.
Article in English | MEDLINE | ID: mdl-21716349

ABSTRACT

Our recent work has showed that diffractively coupled nanoplasmonic arrays for Fourier transform infrared (FTIR) microspectroscopy can enhance the Amide I protein vibrational stretch by up to 10(5) times as compared to plain substrates. In this work we consider computationally the impact of a microscope objective illumination cone on array performance. We derive an approach for computing angular- and spatially-averaged reflectance for various numerical aperture (NA) objectives. We then use this approach to show that arrays that are perfectly optimized for normal incidence undergo significant response degradation even at modest NAs, whereas arrays that are slightly detuned from the perfect grating condition at normal incidence irradiation exhibit only a slight drop in performance when analyzed with a microscope objective. Our simulation results are in good agreement with microscope measurements of experimentally optimized periodic nanoplasmonic arrays.

4.
Appl Opt ; 46(16): 3150-5, 2007 Jun 01.
Article in English | MEDLINE | ID: mdl-17514268

ABSTRACT

What is believed to be a new concept for the measurement of micrometer-sized particle trajectories in an inlet air stream is introduced. The technique uses a light source and a mask to generate a spatial pattern of light within a volume in space. Particles traverse the illumination volume and elastically scatter light to a photodetector where the signal is recorded in time. The detected scattering waveform is decoded to find the particle trajectory. A design is presented for the structured laser beam, and the accuracy of the technique in determining particle position is demonstrated. It is also demonstrated that the structured laser beam can be used to measure and then correct for the spatially dependent instrument-response function of an optical-scattering-based particle-sizing system for aerosols.

SELECTION OF CITATIONS
SEARCH DETAIL
...