Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Ann Vasc Surg ; 100: 39-46, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38104925

ABSTRACT

BACKGROUND: To evaluate the safety and efficacy of endovascular denervation (EDN) as an adjunct to percutaneous vascular intervention (PVI) for peripheral artery disease (PAD). METHODS: From August 2019 to April 2021, 38 eligible patients with PAD enrolled in this study were randomly and equally assigned into 2 groups: the PVI group and the PVI + EDN group treated with EDN at the iliac and femoral arteries before PVI. The primary endpoint was the improvement in the ankle brachial index at 6 months after the procedure. The secondary endpoints were transcutaneous oxygen pressure (TcPO2), Rutherford category, numerical rating scale score, and safety. RESULTS: The technical success rates of PVI and EDN were 100%, and no device-related or procedure-related major adverse events occurred in either group. Compared with PVI alone, PVI + EDN demonstrated a significant improvement in limb hemodynamics at 6 months (Δ ankle brachial index 0.44 ± 0.31 vs. 0.24 ± 0.15, P = 0.018). Microcirculatory perfusion of PAD was significantly better at 6 months in the PVI + EDN group (ΔTcPO2, 15.68 ± 16.72 vs. 4.95 ± 13.43, P = 0.036). The Rutherford category was significantly improved in the PVI + EDN group in comparison with the PVI group at the 3-month follow-up (100.00% vs. 68.42%, P = 0.02). The decrease in the numerical rating scale score in the PVI + EDN group was greater than that in the PVI group at 1 week following the procedure (3 [2-5] vs. 4 [4-6], P = 0.022). CONCLUSIONS: In this single-center pilot analysis of a heterogeneous cohort of patients with PAD, PVI with EDN demonstrated a significant improvement in limb ischemia at 6 months compared with PVI alone.


Subject(s)
Endovascular Procedures , Peripheral Arterial Disease , Humans , Microcirculation , Treatment Outcome , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/surgery , Ischemia/diagnostic imaging , Ischemia/surgery , Denervation , Endovascular Procedures/adverse effects , Endovascular Procedures/methods , Risk Factors
2.
J Vasc Interv Radiol ; 34(7): 1135-1142, 2023 07.
Article in English | MEDLINE | ID: mdl-36906134

ABSTRACT

PURPOSE: To analyze the risk factors for access-related adverse events (AEs) of the preclose technique in thoracic endovascular aortic repair (TEVAR). MATERIALS AND METHODS: Ninety-one patients with Stanford type B aortic dissection who underwent the preclose technique in TEVAR between January 2013 and December 2021 were included. According to the occurrence of access-related AEs, the patients were divided into 2 groups: those with AE and those without AE. Age, sex, combined diseases, body mass index, skin depth, femoral artery diameter, access calcification, iliofemoral artery tortuosity, and sheath size were recorded for risk factor analysis. The sheath-to-femoral artery ratio (SFAR), the ratio of the femoral artery inner diameter (in millimeters) to the sheath's outer diameter (in millimeters), was also included in the analysis. RESULTS: SFAR was identified as an independent risk factor for AEs using multivariable logistic analysis (odds ratio, 251.748; 95% CI, 7.004-9,048.534; P = .002). The cutoff value of SFAR was 0.85 and was related to a higher incidence of access-related AEs (5.2% vs 33.3%, P = .001), especially to a higher stenosis rate (0.0% vs 21.2%, P = .001). CONCLUSIONS: SFAR is an independent risk factor for access-related AEs of preclose in TEVAR with a cutoff value of 0.85. SFAR could be a new criterion for preoperative access evaluation in high-risk patients that may allow the detection and treatment of access-related AEs at the early stage.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Endovascular Aneurysm Repair , Tomography, X-Ray Computed , Treatment Outcome , Risk Factors , Aortic Dissection/diagnostic imaging , Aortic Dissection/surgery , Endovascular Procedures/adverse effects , Endovascular Procedures/methods , Retrospective Studies , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/etiology , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/methods
3.
Acta Biomater ; 146: 495-505, 2022 07 01.
Article in English | MEDLINE | ID: mdl-35487426

ABSTRACT

Biodegradable stents can degrade step by step and thereby avoid secondary removal by endoscopic procedures in contrast to metal stents. Herein, a biodegradable composite stent, a magnesium (Mg)-based braided stent with a surface coating of poly (lactic-co-glycolic acid) (PLGA) containing paclitaxel (PTX), was designed and tested. By adding this drug-loaded polymer coating, the radial force of the stent increased from 33 Newton (N) to 83 N. PTX was continuously released as the stent degraded, and the in vitro cumulative drug release in phosphate-buffered saline for 28 days was 115 ± 13.5 µg/mL at pH = 7.4 and 176 ± 12 µg/mL at pH = 4.0. There was no statistically significant difference in the viability of fibroblasts of stent extracts with different concentration gradients (P > 0.05), while the PTX-loaded stents effectively promoted fibroblast apoptosis. In the animal experiment, the stents were able to maintain esophageal patency during the 3-week follow-up and to reduce the infiltration of inflammatory cells and the amount of fibrous tissue. These results showed that the PTX-PLGA-coated Mg stent has the potential to be a safe and effective approach for benign esophageal stricture. STATEMENT OF SIGNIFICANCE: We designed a biodegradable composite stent, having poly (lactic-co-glycolic acid) (PLGA) containing paclitaxel (PTX) coated the surface of the magnesium (Mg)-based braided stent. We evaluated in vitro and in vivo characteristics of the Mg esophageal stent having a PLGA coating plus a variable concentration of PTX in comparison with the absence of PTX PLGA coating. The PTX PLGA stents exerted higher radial force than stents without coating, degraded more quickly in an acid medium, and effectively promoted fibroblast apoptosis in vitro experiments. In a rabbit model of caustic-induced esophageal stricture, there was an increased lumen and decreased inflammation of the esophageal wall in the animals stented with PTX-PLGA versus the sham group, indicating a potential approach for benign esophageal stricture.


Subject(s)
Esophageal Stenosis , Paclitaxel , Animals , Magnesium/pharmacology , Paclitaxel/pharmacology , Polymers , Rabbits , Stents
SELECTION OF CITATIONS
SEARCH DETAIL
...